Rule 11, Punjab Factories Rules 1952: Warpers
Punjab Factories Rules 1952 - Rule 11
Text of rule 11
Warpers
11. Warpers.-Swiveled double-bar gates shall be installed on all warpers operating in excess
of 410 meters minimum and shall have interlocking arrangements, except for the purpose of
inching or jogging.
Provided that top and bottom bars of gates shall be at least 1.05 and 0.53
meters high from the floor or working plate form, and gate shall be locked 38 mm from vertical
tangement to the bean head.
12 Slashers: - (1) Cylinder dryers :-( a) All open nips of in running rolls shall be
guarded by nip guards conforming to the requirements in clause 7.
(b) When slashers are operated by control levers, these levers shall be
connected to a horizontal bar or treadle located not more than 170mm above the
floor to control the operation from any point.
(c) Slashers operated by such button control shall have stop and start buttons
located at each end of the machine, and additional buttons located on both sides of
the machine at the size box and the delivery end and if calender rolls are used,
additional buttons shall be provided at both sides of machines at points near the
nips, except when slashers are equipped with an enclosed dryer as in such clause
(b).
2 Enclosed hot air dryer –
(a) All open nips of the top squeezing rollers shall be guarded by nip
guards conforming to the requirement specified in sub-clause (2) of
clause 7.
(b) When slashers are operated by control layers, these levers shall be
connected to a horizontal bar or treadle located not more than 170 cm.
above the floor to control the operation from any point.
( c) Slashers operated by push-button control shall have stop and start
buttons located at each end of the machine and additional stop and start
buttons located on both sides of the machine at intervals spaced not more
than 1.83 meters on centers.
13 Looms –
(1) Each loom shall be equipped with suitable guards designed to minimize
the danger from flying shuttles.
(2) Beam weights for tension in beam shall be of such construction so as
prevent it from falling during its adjustment.
14 Valves of Kiers, tanks, and other containers. –
(1) Each valve controlling the flow of steam injurious gases or liquids into a
kier or any other tank or container into which a person is likely to enter
in connection with a process, operation, maintenance or for any other
purpose, shall be provided with a suitable lock the valve securely in the
closed position and retain the key with him before entering the kier tank
or container.
(2) Wherever boiling tanks, caustic tanks and any other containers from
which liquids, which are hot, corrosive or toxic, may overflow or splash,
are so located that the operator cannot see the contents from the floor
or working areas, emergency shut off valves which can be controlled
from a point not subject to danger of splash shall be provided to prevent
danger.
Previous and next
Questions people ask
Is rule 11 of Punjab Factories Rules 1952 still in force?
No repeal of Punjab Factories Rules 1952 is recorded.