Gill boxes
7. Gill boxes.-(1) The feed and shall be guarded so as to prevent fingers being caught in
the pins of the intersecting fillers.
(2) All nips of in-running rolls shall be guarded by Suitable nip guards conforming to the
following specifications.
Any opening which the guard may permit when fitted in position shall be so restricted
with respect to the distance of the opening from any nip point through that opening from
any nip point through that the maximum width of the opening shall not exceed the
following :-
Distance of opening from nip point Maximum width of opening
0 to 38 mm 6 mm
39 to 63 mm 10 mm
64 to 88 mm 13 mm
89 to 140 mm 15 mm
141 to 165 mm 19 mm
166 to 190 mm 22 mm
191 to 215 mrn 32 mm