(48) Direction regarding construction of building-No. 11/2/64-UTFI(2)2000/3496- In exercise of the
powers conferred under section 4 of the Capital of Punjab (Development and Regulation) Act. 1952, the
Chief Administrator, Union Territory, Chandigarh hereby issues (ho following directions regarding
construction of buildings in the Union Territory, Chandigarh:
(1) In.the City Centre, Sector 17, maximum 4 sub-divisions of two bay shops of size 34-6'’x I Q3’-0" dial I
be allowed at ground floor only, Any Size of the shop can be taken up by the owner in the module of 17-
3"xI7’-3". In throe bay shops, maximum number of sub-divided shops shall be 6.
(2) Regarding the specifications of the building material to be provided on front facade of the common
wall and jambs, the front facade of common wall should have a material as per architectural controls
applicable to the SCOs, the side jambs may be provided with building material as per the discretion of the
owner. The Department of Urban Planning shall prepare a standard detail for the same and incorporate it
in the Architectural control after approval.
(3) The provision of a cutout of the maxim urn size of 1 square meter. With a flap dour on top of it
alongwith the provision of Cat-ladder may be allowed in all SCOs/SCFs, subject to the approval of the
Chief Administrator and that the opening so created shall remain within the parapet height.
(4) In case where sub-division of (he shop is allowed by the Chandigarh Administration on payment of
prescribed fees determined by the Estate Officer, Union Territory, Chandigarh, the following will be
permitted:- (.i) An additional entry with door shutter opening inside the shop may
be provided subject to the condition that ventilation for the basement floor In the remaining part of die
glazing is not disturbed. However, the size of the additional entry shall be of the same size as that of
existing entry.
(B)An additional door in the rear side of the building of the same width height and design as that of the
existing door qii the rear side will be allowed as shown in the Architectural Control Site eta.
(c) The party wall between the two sub-divided shops may be constructed up to ceiling height. The party
wall shall be of arty fire retardant material.
(5) The shop owner shall have a choice regarding location of dour subject to the condition that only one
entrance is provided and proper light and ventilation is duly ensured.
(6) The initial sanctioning of the building plans for fresh construction shall remain mandatory eus at
present. But, if any realignment/readjustment of internal temporary partitions in the existing building is
required at a later stags, the registered architect, supervising the same shall ensure that the said changes
are within building and architectural control as applicable to dial building and he shall submit a copy of the
revised plan prior to the execution of work at site to die Estate Officer for record and reference alongwith
a certificate conforming to the above conditions. In this case, re-sanctioning shall not be required.
However, any change in structure or permanent features such as toilet, stairs, lifts, public health ducts
shall not be permitted. The SDO(B) shall visit/ inspect the premises within a period of 3 months and verify
the same. If the construction is not as per revised building plan submitted by the architect orany
infringement of Building Rules is detected or in other words certificate submitted by the Architect is found
to be wrong, the architect shall be held responsible for all consequences and action shall be initiated
against him/her as per rules. The facility shall be available only on the upper floors of SCOs and not to
the SCFs, as the same are meant for residential purposes.
(7) A zone for all services on terrace shall be fixed instead of fixing individual zones forcach service. The
provision of solar water tanks and cooling towers for air conditioning shall be made on roof top subject to
the condition that it’s height is restricted to 10-0" and it is placed IO'-O" away from front and rear wall and
end walls and 4'-0" away from common party walls.
(8) In view of new joinery materials flooding the market, relaxation shall be given regarding choice of
specifications for external glazing. Any material except timber shall be allowed for glazing on external
facades of commercial buildings. The use of timber shall, however, be allowed on show windows in the
public verandahs of the building. All glazing/ doors/windows or openings within the enclosed courtyards or
external surfaces which are behind parapets/jallis/walls etc. may be of any size as per the requirements
of the owner subject to the condition that the Lintel-Soffit of such glazing/windows/door/openings is not
higher than 6-9". This is subject to prior approval of building plans.
(9) The shop owners shall be free to adopt any design and material for flooring in public corridor in order
to make shop entrance more attractive. The shop owners shall be at liberty to adopt any material /design
within the area earmarked as laid down in the design prepared by the Department of Urban Planning,
Chandigarh Administration. However, the material used in public corridor shall not be glazed and slippery
and same level is maintained as existing. The architectural control of all SCOs and SCFs shall be
amended accordingly after obtaining approval of the Chief Administrator.
(10) The sky-light on roof top of commercial buildings which are not visible from the street shall not be
compulsory, provided minimum light and ventilation as stipulated in building rules is ensured. Sky-lights
shall also not be compulsory in all those commercial buildings where deficiency of natural light and
ventilation is compensated by artificial lighting, ventilation and air-conditioning etc. as stipulated in the
building bye-laws. [See Chandigarh Admn. Gaz. (Extra) dated 30-3-2000 published on 30-3-2000 at page
323J