Record of white-washing etc

16. Record of white-washing etc. — The record of dates on which white-washing, colour- washing, varnishing, etc. are carried out shall be entered in a Register maintained in Form No. 7. #[16A. Compound to be kept clean. — The compound surrounding every factory shall be maintained in a sanitary and clean condition, free of rubbish, filth or debris.] Rule prescribed under sub-section (2) of section 12 $[17. Disposal of Trade Wastes and Effluents.— The arrangements made in every factory for the treatment of wastes and effluents due to the manufacturing processes carried on therein shall be in accordance with those approved by the relevant Water And Air pollution Boards appointed under the Water (Prevention and Control of Pollution) Act, 1974 and the Air (Prevention and Control of Pollution) Act, 1981 and other appropriate authorities".] @[17A. Limits of temperature and air movement.— (1) In any factory the maximum wet bulb temperature of air in a work-room at a height of 1.5 metres above the floor level shall not exceed 30° C and adequate air movement of at least 30 metres per minute shall be provided, and in relation to dry bulb temperature the wet bulb temperature in the work-room at the said height shall not exceed that shown in the schedule below, or as regards a dry bulb reading intermediate between the two dry bulb readings that specified in relation to the higher of these two dry bulb readings.] --------------------------------------------------------------------------------------------------------------------- @. Substituted vide Notification No. F1(112)L&E/76 dated 24.3.1979; Rajasthan Gazette Part IV-Ga(1). dated 26.4.1979 #. Inserted vide Notification No. F. 2(58)/L&E/64. dated 25.3.1968; Rajasthan Gazette Part IV(Ga) dated 11.7.68. $. Deleted vide Notification No. F.4(3) Shram/88 dated 8.1.1991, published Rajasthan Gazette Part 3(Ga) dated Rajasthan 25.6.1992. Schedule Dry bulb temperature Wet bulb temperature °C °C 30 29.0 31 28.9 32 28.8 33 28.7 34 28.6 35 28.5 36 28.4 37 28.3 38 28.2 39 28.1 40 28.0 41 27.9 42 27.8 43 27.7 44 27.6 45 27.5 46 27.4 47 27.3 Provided that if the temperature measured with a thermometer inserted in a hollow globe of 15 cms. dia. coated mat black outside and kept in the environment for not less than 20 minutes exceeds the dry-bulb temperature of air, the temperature so recorded by the globe thermometer shall be taken in place of the dry bulb temperature: Provided further that when the reading of the wet bulb temperature outside in the shade exceed 27°C the value of the wet bulb temperature allowed in the Schedule for a given dry bulb temperature may be correspondingly exceeding to the same extent: Provided further that this requirement shall not apply in respect of the factories covered by section 15 and in respect of factories where the nature of work carried on involves production of excessively high temperatures referred in clause (ii) of sub- section (1) of which workers are exposed for short period of time not exceeding one hour followed by an interval of sufficient duration in thermal environments not exceeding those otherwise laid down in this rule: Provided further that the Chief Inspector having due regard to the health of the workers, may in special and exceptional circumstances, by an order in writing exempt any factory or part of a factory from the foregoing requirement, in so far as restricting the thermal conditions within the limits laid down in the Schedule are concerned, to the extent he may consider necessary, subject to such conditions as he may specify. (2) Provision of thermometers.— (i) If it appears to the Inspector that in any factory, the temperature of air in a work room is sufficiently high and is likely to exceed the limits prescribed in sub-rule (1), he may serve on the manager of the factory an order requiring him to provide sufficient number of whirling hygrometers or any other type of hygrometers and direct that the dry-bulb and wet-bulb reading in each such work room shall be recorded at such positions as approved by the Inspector. Twice during each working shift by a person specially nominated for purpose by the manager and approved by the Inspector. (ii) If the Inspector has reason to believe that a substantial amount of heat is added inside the environment of a work room by radiation from walls, roofs or other solid surroundings, he may serve on the manager of the factory an order requiring him to provide one or more globe thermometers referred to in the first proviso, in sub-rule (1) and further requiring him to place the globe thermometers at places specified by him and keep a record of the temperatures in a suitable register. (3) Ventilation.— (1) In every factory the amount of ventilating openings in a work room below the caves shall, except where mechanical means of ventilation as required by sub- rule (2) are provided, be of an aggregate area of not less than 15% of the floor area and so located as to afford a continued supply of fresh air: Provided that the Chief Inspector may relax the requirements regarding the amount of ventilating openings if he is satisfied that having regard to the location of the factory, orientation of the work room: prevailing winds, roof height and the nature of manufacturing process carried on, sufficient supply of fresh air into the work room is afforded during most part of the working time: Provided further that this requirement shall not apply in respect of work rooms of factories:— (i) covered by section 15; or (ii) in which temperature and humidity are controlled by refrigeration; (iii) where in any factory owing to special circumstances such as situation with respect to adjacent buildings and height of the building with respect to floor space, the requirement of ventilation openings under sub-clause (1) cannot be complied with or in the opinion of the Inspector the temperature of air in a work room is sufficiently high and is likely to exceed the limits prescribed in sub-rule, he may serve on manager of the factory an order requiring him to provide additional ventilation either by means of roof ventilators or by mechanical means; (iv) amount of fresh air supplied by mechanical means of ventilation in an hour shall be equivalent to at least six times the cubic capacity of the work room and shall be distributed evenly throughout the work room without dead air pockets or undue draughts caused by high inlet velocities; (v) in regions where in summer (15th March to 15th July) dry bulb temperatures of outside air in the shade during most part of the day exceed 35°C and simultaneous wet bulb temperatures are 25°C or below and in the opinion of the Inspector the manufacturing process carried on in the work room of a factory permits thermal environments with relative humidity of 50% or more, the Inspector may serve on the manager of the factory an order to have sufficient supply of outside air for ventilation cooled by passing it through water sprays either by means of unit type of evaporative air coolers (desert cooler) or, where supply of outside air is provided by mechanical means through ducts in a plenum system, by means of Central air washing plants.] Rules 18 to 28 prescribed under sub-section (1) of section 15

Previous and next

All provisions of Rajasthan Factories Rules,1951

Questions people ask

Is rule 16 of Rajasthan Factories Rules,1951 still in force?

No repeal of Rajasthan Factories Rules,1951 is recorded.