Record of white-washing etc
16. Record of white-washing etc. — The record of dates on which white-washing, colour-
washing, varnishing, etc. are carried out shall be entered in a Register maintained in Form
No. 7.
#[16A. Compound to be kept clean. — The compound surrounding every factory shall be
maintained in a sanitary and clean condition, free of rubbish, filth or debris.]
Rule prescribed under sub-section (2) of section 12
$[17. Disposal of Trade Wastes and Effluents.— The arrangements made in every
factory for the treatment of wastes and effluents due to the manufacturing processes carried
on therein shall be in accordance with those approved by the relevant Water And Air
pollution Boards appointed under the Water (Prevention and Control of Pollution) Act, 1974
and the Air (Prevention and Control of Pollution) Act, 1981 and other appropriate
authorities".]
@[17A. Limits of temperature and air movement.— (1) In any factory the maximum wet
bulb temperature of air in a work-room at a height of 1.5 metres above the floor level shall
not exceed 30° C and adequate air movement of at least 30 metres per minute shall be
provided, and in relation to dry bulb temperature the wet bulb temperature in the work-room
at the said height shall not exceed that shown in the schedule below, or as regards a dry
bulb reading intermediate between the two dry bulb readings that specified in relation to the
higher of these two dry bulb readings.]
---------------------------------------------------------------------------------------------------------------------
@. Substituted vide Notification No. F1(112)L&E/76 dated 24.3.1979; Rajasthan Gazette
Part IV-Ga(1). dated 26.4.1979
#. Inserted vide Notification No. F. 2(58)/L&E/64. dated 25.3.1968; Rajasthan Gazette Part
IV(Ga) dated 11.7.68.
$. Deleted vide Notification No. F.4(3) Shram/88 dated 8.1.1991, published Rajasthan
Gazette Part 3(Ga) dated Rajasthan 25.6.1992.
Schedule
Dry bulb
temperature
Wet bulb
temperature
°C °C
30 29.0
31 28.9
32 28.8
33 28.7
34 28.6
35 28.5
36 28.4
37 28.3
38 28.2
39 28.1
40 28.0
41 27.9
42 27.8
43 27.7
44 27.6
45 27.5
46 27.4
47 27.3
Provided that if the temperature measured with a thermometer inserted in a hollow
globe of 15 cms. dia. coated mat black outside and kept in the environment for not less than
20 minutes exceeds the dry-bulb temperature of air, the temperature so recorded by the
globe thermometer shall be taken in place of the dry bulb temperature:
Provided further that when the reading of the wet bulb temperature outside in the shade
exceed 27°C the value of the wet bulb temperature allowed in the Schedule for a given dry
bulb temperature may be correspondingly exceeding to the same extent:
Provided further that this requirement shall not apply in respect of the factories covered
by section 15 and in respect of factories where the nature of work carried on involves
production of excessively high temperatures referred in clause (ii) of sub- section (1) of
which workers are exposed for short period of time not exceeding one hour followed by an
interval of sufficient duration in thermal environments not exceeding those otherwise laid
down in this rule:
Provided further that the Chief Inspector having due regard to the health of the workers,
may in special and exceptional circumstances, by an order in writing exempt any factory or
part of a factory from the foregoing requirement, in so far as restricting the thermal
conditions within the limits laid down in the Schedule are concerned, to the extent he may
consider necessary, subject to such conditions as he may specify.
(2) Provision of thermometers.— (i) If it appears to the Inspector that in any factory, the
temperature of air in a work room is sufficiently high and is likely to exceed the limits
prescribed in sub-rule (1), he may serve on the manager of the factory an order requiring
him to provide sufficient number of whirling hygrometers or any other type of hygrometers
and direct that the dry-bulb and wet-bulb reading in each such work room shall be recorded
at such positions as approved by the Inspector. Twice during each working shift by a person
specially nominated for purpose by the manager and approved by the Inspector.
(ii) If the Inspector has reason to believe that a substantial amount of heat is added
inside the environment of a work room by radiation from walls, roofs or other solid
surroundings, he may serve on the manager of the factory an order requiring him to
provide one or more globe thermometers referred to in the first proviso, in sub-rule (1)
and further requiring him to place the globe thermometers at places specified by him
and keep a record of the temperatures in a suitable register.
(3) Ventilation.— (1) In every factory the amount of ventilating openings in a work room
below the caves shall, except where mechanical means of ventilation as required by sub-
rule (2) are provided, be of an aggregate area of not less than 15% of the floor area and so
located as to afford a continued supply of fresh air:
Provided that the Chief Inspector may relax the requirements regarding the amount of
ventilating openings if he is satisfied that having regard to the location of the factory,
orientation of the work room: prevailing winds, roof height and the nature of manufacturing
process carried on, sufficient supply of fresh air into the work room is afforded during most
part of the working time:
Provided further that this requirement shall not apply in respect of work rooms of
factories:—
(i) covered by section 15; or
(ii) in which temperature and humidity are controlled by refrigeration;
(iii) where in any factory owing to special circumstances such as situation with respect
to adjacent buildings and height of the building with respect to floor space, the
requirement of ventilation openings under sub-clause (1) cannot be complied with or
in the opinion of the Inspector the temperature of air in a work room is sufficiently high
and is likely to exceed the limits prescribed in sub-rule, he may serve on manager of
the factory an order requiring him to provide additional ventilation either by means of
roof ventilators or by mechanical means;
(iv) amount of fresh air supplied by mechanical means of ventilation in an hour shall be
equivalent to at least six times the cubic capacity of the work room and shall be
distributed evenly throughout the work room without dead air pockets or undue
draughts caused by high inlet velocities;
(v) in regions where in summer (15th March to 15th July) dry bulb temperatures of
outside air in the shade during most part of the day exceed 35°C and simultaneous
wet bulb temperatures are 25°C or below and in the opinion of the Inspector the
manufacturing process carried on in the work room of a factory permits thermal
environments with relative humidity of 50% or more, the Inspector may serve on the
manager of the factory an order to have sufficient supply of outside air for ventilation
cooled by passing it through water sprays either by means of unit type of evaporative
air coolers (desert cooler) or, where supply of outside air is provided by mechanical
means through ducts in a plenum system, by means of Central air washing plants.]
Rules 18 to 28 prescribed under sub-section (1) of section 15
Previous and next
Questions people ask
Is rule 16 of Rajasthan Factories Rules,1951 still in force?
No repeal of Rajasthan Factories Rules,1951 is recorded.