Rule 60, Uttar Pradesh Factory Rules, 1950: Exemptions
Uttar Pradesh Factory Rules, 1950 - Rule 60
Text of rule 60
Exemptions
60. Exemptions.—(1) The requirements of sub-section (4) of Section 37 shall
not apply to the following processes carried on in any factory :
(a) The operation of repairing a water sealed gas-holder by the electric welding
process, subject to the conditions that:
(i) The gas-holder shall contain only the following gases, separately or mixed at a
pressure greater than atmospheric pressure, namely, town gas coke, oven gas,
producer gas, blast furnace gas, or gases other than air, used in their
manufacture :
Provided that this exemption shall not apply to any gas-holder containing
acetylene or mixture of gases to which acetylene has been added intentionally.
(ii) Welding shall only be done by the electric welding process and shall be
carried out by experienced operatives under the constant supervision of a
competent person.
(b) The operations of cutting or welding steel or wrought iron gas mains and
service pipes by the application of heat, subject to the conditions that:
(i) The main or service pipes shall be situated in the open air, and it shall contain
only the following gases, separately or mixed at a pressure, namely, gas coke,
oven gas, or producer gas, blast furnace gas, or gases other than air, used in their
manufacture.
(ii) The main or service pipes shall not contain acetylene or any gas or mixture of
gases to which acetylene has been added intentionally.
(iii) The operation shall be carried out by an experienced person or persons and
at least two persons (including those carrying out the operations) experienced in
work on gas mains and over 18 years of age shall be present during the
operation.
(iv) The site of the operation shall be free from any inflammable or explosive gas
vapour.
(v) Where acetylene gas is used as a source of heat in connection within operated
it shall be compressed and contained in a porous substance in a cylinder.
(vi) Prior to the application of any flame to the gas, main or service pipes shall be
pierced or drilled and the escaping gas ignited.
(c) The operation of repairing an oil tank by the electric welding process subject
to the following conditions :
(i) The only oil contained in the tank shall have a flash point of not less than
150°F. (close test) and a certificate to this effect shall be obtained from a
competent analyst.
(ii) The analyst's certificate shall be kept available for inspection by an Inspector.
(iii) The welding operation shall be carried out only on the exterior surface of the
tank at a place (a) which is free from oil or oil leakage in inflammable quantities
and (b) which is not less than one foot below the nearest part of the surface of the
oil within the tank.
(iv) Welding shall be done only by the electric welding and shall be carried out
by experienced operatives under the constant supervision of a competent person.
(2) Nothing in this rule shall be deemed to make any exemption from the
requirements of the provisions of rules made under any other Act.
MEANS OF ESCAPE IN CASE OF FIRE [SECTION 38(7)]
61-Fire.
(1) Processes, equipment, plant, etc., involving serious explosion and serious fire
hazards -
(a) All processes, storages, equipments, plants etc. involving serious explosion
and flash fire hazards shall be located in segregated buildings where the
equipment shall be so arranged that only a minimum number of employees are
exposed to such hazards at any one time.
(b) All industrial processes involving serious fire hazard should be located in
buildings or work places separated from one another by walls of fire-resistant
constructions.
(c) Equipment and plant involving serious fire or flash fire hazard shall,
wherever possible, be so constructed and installed that in case of fire, they can be
easily isolated.
(d) Ventilation ducts, pneumatic conveyors and similar equipments involving a
serious fire risk should be provided with flame arresting or automatic fire
extinguishing appliances.
(e) In all workplaces having serious fire or flash fire hazards, passages between
machines, installations or piles of materials should be at least 90cm wide.
(2) Access for fire fighting :-
Buildings and plant shall be so laid and roads, passage ways etc. so maintained
as to permit unobstructed access for fire fighting.
(3) Protection against lightning:- Protection from lightning shall be provided for-
(i) buildings in which explosive or highly flammable substances are
manufactured, used handled or stored;
(ii) storage tanks containing oils, paints, or other flammable liquids
(iii) grain elevators ; and
(iv) buildings, tall chimneys or stacks where flammable gases, fumes, dust or lint
are likely to be present.
(4) Explosive :- All explosives shall be handled, transported, stored and used in
accordance with the provisions in the Indian Explosives Act, 1884.
(5) Precautions against ignition..- Wherever there is danger of fire or explosion
from accumulation of flammable or explosive substances in air-
(a) all electrical apparatus shall either be excluded from the area of risk or they
shall he of such construction and so installed and maintained as to prevent the
danger of their being a source of ignition ;
(b) Effective measures shall be adopted for prevention of accumulation of static
charges to a dangerous extent ;
(c) workers shall wear shoes without iron or steel nails or any other exposed
ferrous materials which is likely to cause sparks by friction ;
(d) smoking, lighting or carrying of matches, lighters or smoking materials shall
be prohibited;
(e) transmission belts with iron fasteners shall not be used ; and
(f) all other precautions as are reasonably practicable shall be taken to prevent
initiation of ignition from all other possible sources such as open flames,
frictional sparks overheated surfaces of machinery or plant, chemical or physical-
chemical reaction and radiant heat.
(6) Spontaneous ignition:- Where materials are likely to induce spontaneous
ignition, care shall be taken to avoid formation of air pocket and to ensure
adequate ventilation.
(7) Cylinders containing compressed gas :- Cylinders containing compressed gas
may only be stored in open if they are protected against excessive variation of
temperature, direct rays of sun, or continuous dampness. Such cylinders shall
never be stored near highly flammable substances, furnaces or hot processes. The
room where such cylinders are stored shall have adequate ventilation.
(8) Storage of flammable liquids:-
(a) The quantity of flammable liquids in any work room shall be the minimum
required for the process or processes carried on in such room. Flammable liquids
shall be stored in suitable containers with close fitting covers :
Provided that not more than 20 litres of flammable liquids having a flash point of
21deg C or less shall be kept or stored in any work room.
(b) Flammable liquids shall be stored in closed containers and in limited
quantities in well ventilated rooms of fire resisting constructions which are
isolated from the remaining of the building by fire walls and self closing fire
doors.
(c) Large quantities of such liquids shall be stored in isolated adequately
ventilated building or fire resisting construction or in storage tanks, preferably
under ground and at a distance from any building as required in the Petroleum
Rules, 1976.
(d) Effective steps shall be taken to prevent leakage of such liquids into
basements, sumps or drains and to confine any escaping liquid within safe limits.
(e) Coal, oil, gasoline, or other flammable materials shall not be poured in any
sewer or drain.
(9) Accumulation of flammable dust, gas, fume or vapour in air or flammable
waste material on the floors-
(a) Effective steps shall be taken for removal or prevention of the accumulation in
the air of flammable dust, gas, fume or vapour to an extent which is likely to be
dangerous.
(b) No waste material Of a flammable nature shall be permitted to accumulate on
the floors and shall be removed at least once in a day or shift, and more often,
when possible, such materials shall be placed in suitable metal containers with
covers wherever possible.
(10) Fire exits:-
(a) In this rule -
(i) "horizontal exit" means an arrangement which allows alternative egress from
a floor area to another floor at or near the same level in an adjoining building or
an adjoining part of the same building with adequate separation ; and
(ii) "travel distance" means the distance an occupant has to travel to reach an exit.
(b) An exit may be a doorway, corridor, passage way to any internal or external
stair way or to a verandah. An exit may also include a horizontal exit leading to
an adjoining building at the same level.
(c) Lifts, escalators and revolving doors shall not be considered as exits for the
purpose of this sub-rule.
(d) In every room of a factory exits sufficient to permit safe escape of the
occupants in case of fire or other emergency shall be provided which shall be free
of any obstruction.
(e) The exits shall be clearly visible and suitable illuminated with suitable
arrangement, whatever artificial lighting is to be adopted for this purpose, to
maintain the required illumination in case of failure of the normal source of
electric supply.
(f) The exits shall be marked in a language understood by the majority of the
workers.
(g) Fire resisting doors or roller shutters shall be provided at appropriate places
along the escape routes to prevent spread of fire and smoke, particularly at the
entrance of lifts or stairs where funnel or flue effect may be created inducing an
upward spread of fire.
(h) All exits shall provide continuous means of egress to the exterior of a
building or to an exterior open space leading to a street.
(i) Exits shall be so located that the travel distance on the floor shall not exceed 30
metres.
(j) In case of those factories where high hazard materials are stored or used, the
travel distance to the exit shall not exceed 22.5 metres and there shall be at least
two ways of escape from every room, however small except toilet rooms, so
located that the points of access thereto are out of or suitably shielded from areas
of high hazard.
(k) Wherever more than one exit is required for any room space or floor, exits
shall be placed as remote from each other as possible and shall be arranged to
provide direct access in separate directions from any point in the area served.
(l) The unit of exit width used to measure capacity of any exit shall be 50 cm. A
clear width of 25 cm shall be counted as an additional half unit. Clear width of
less than 25 cm shall not be counted for exit width.
(m) Occupants per unit width shall be 50 for stairs and 75 for doors.
(n) For determining the exits required, the occupant load shall be reckoned on
the basis of actual number of occupants within any floor area or 10 square metres
per person, whichever is more.
(o) There shall not be less than two exits, serving every floor area above and
below the ground floor, and at least one of them shall be an internal enclosed
stairway.
(p) For every building or structure used for storage only, and every section
thereof considered separately, shall have access to at least one exit so arranged
and located as to provide a suitable means of escape for any person employed
therein, and in any such room wherein more than 10 persons as may be normally
present at least two separate means of exit shall be available, as remote from each
other as practicable.
(q) Every storage area shall have access to at least one means of exit which can be
readily opened.
(r) Every exit door way shall open into an enclosed stairway, a horizontal exit on
a corridor or passage way providing continuous and protected means of egress.
(s) No exit doorway shall be less than 100 cm. in width Doorways shall be not
less than 200 cm. in height.
(t) Exit doorways shall open outwards, that is, away from the room but shall not
obstruct the travel along any exit. No door when opened, shall reduce the
required width of stairway or landing to less than 90 cm. Overhead or sliding
doors shall not be installed for this purpose.
(u) An exit door shall not open immediately upon a flight of stairs. A landing
atleast the width of the doorway shall be provided in the stairway at each
doorway. The level of landing shall be the same as that of the floor which it
serves.
(v) The exit doorways shall be openable from the side which they serve without
the use of a key.
(w) Exit corridors and passage ways shall be of a width not less than the
aggregate required width of exit doorways leading from there in the direction of
travel to the exterior.
(x) Where stairways discharge through corridors and passageways the height of
the corridors and passageways shall not be less than 2.4 metres.
(y) Internal stairs shall be constructed of non-combustible materials throughout
and at least one of the external stairs, which affords a means of access in case of
fire, shall be of non-combustible material throughout.
(a) Internal stairs shall be constructed as a self-contained unit with at least one
side adjacent to an external wall shall be completely enclosed.
(aa) A staircase shall not be arranged round a lift shaft unless the latter is totally
enclosed by a materials having a fire resistance rating not lower than that of the
type of construction of the former.
(bb) Hollow combustible construction shall not be permitted.
(cc) The minimum width of an internal staircase shall be 115 cm.
(dd) The minimum width of treads without nosing shall be 25 cm for an internal
staircase. The treads shall be constructed and maintained in a manner to prevent
slipping.
(ee) The maximum height of a riser shall be 19 cm. and the number of risers shall
be limited to 12 per flight.
(ff) Hand rails shall be provided with a minimum height of 100 cm and shall be
firmly supported : and where necessary shall be provided on both sides of the
staircase.
(gg) The use of spiral staircase shall be limited to low occupant load and to a
building of height of 9 metres, unless they are connected to platforms such as
balconies and terraces to allow escapes to pause. A spiral staircase shall be not
less than 300 cm in diameter and have adequate headroom.
(hh) The width of a horizontal exit shall be same as for the exit doorways.
(ii) The horizontal exit shall be equipped with at least one fire door of self-closing
type.
(jj) The floor area on the opposite or refuge side of a horizontal exit shall be
sufficient to accommodate occupants of the floor areas served, allowing not less
than 0.3 square metre per person. The refuge area shall be provided with exits
adequate to meet the requirements of this sub-rule. At least one of the exits shall
lead directly to the exterior or street.
(kk) Where there is difference in level between connected areas for horizontal
exit, ramps not more than 1 in 8 slope shall be provided. For this purpose steps
shall not be used.
(ll) Doors in horizontal exits shall be openable at all time.
(mm) Ramps with a slope of not more than 1 to 10 may be substituted for the
requirements of staircase. For all slopes exceeding 1 to 10 and wherever the use
in such as to involve danger of slipping, the ramp shall be surfaced with non-
slipping material.
(nn) In any building not provided with automatic fire alarm a manual fire alarm
system shall be provided if the total capacity of the building is over 500 persons,
or if more than 25 persons are employed above or below the ground floor, except
that no manual fire alarm shall be required in one-storey buildings where the
entire area is undivided and all parts thereof are clearly visible to all occupants.
(11) First-aid fire fighting arrangements :-
(a) In every factory there shall be provided and maintained adequate and
suitable fire fighting equipment for fighting fires in the early stages, those being
referred to first-aid fire fighting equipment in this rule.
(b) The types of first-aid fire fighting equipment to be provided shall be
determined by considering the different types of fire risks which are classified as
follows :-
(i) "Class A fire" - Fire due to combustible materials such as wood, textiles, paper,
rubbish and the like.
(1) "Light hazard" - Occupancies like offices, assembly halls, canteens, rest-
rooms, ambulance rooms and the like;
(2) "Ordinary hazard" - Occupancies like saw mills, carpentry shop, small timber
yards, book binding shops, engineering workshop and the like;
(3) "Extra hazard" - Occupancies like large timber yards, godowns storing fibrous
materials, flour mills, cotton mills, jute mills, large wood working factories and
the like ;
(ii) "Class B fire" - Fire in flammable liquids like oil, petroleum produces,
solvents, grease, paints etc.
(iii) "Class C fire" - Fire-arising out of gaseous substances.
(iv) "Class D fire" - Fire from reactive chemicals, active metals and the like.
(v) "Class E fire" - Fire involving electrical equipment and delicate machinery
and the like.
(c) The number and types of first-aid fire-fighting equipment to be provided shall
be as per the following scale :-
(i) Class-A Fire :-
1. Light Hazard :- One 9 litre water bucket for every 100 square meters of floor
area or part thereof and one 9 litre water type (soda acid or gas pressure or
bucket pump) extinguisher shall be provided for each 6 buckets or part thereof
with a minimum of one extinguisher and two buckets per compartment of the
building. These equipments shall be so distributed over the entire floor areas that
a person shall have to travel not more than 25 metres from any point to reach the
nearest equipment.
2. Ordinary Hazard :- One 9 litre water bucket for every 100 square meters of
floor area or part thereof and one 9 litre water type (soda acid or gas pressure or
bucket pump) extinguisher shall be provided for each six buckets or part thereof,
with a minimum of 2 extinguishers and 4 buckets per compartment of the
building. These equipments shall be so distributed over the entire floor areas that
a person shall have to travel not more than 15 metres from any point to reach the
nearest equipment.
3. Extra hazard :- The scale of equipment would be what is prescribed for
ordinary hazard and, in addition, such extra equipments as, in the opinion of the
Inspector are necessary having regard to the special nature of occupancy :
Provided that in special cases, the Inspector, after taking into consideration the
circumstances, authorise that the buckets prescribed in this clause may be
dispensed with provided the number of the extinguishers provided in double of
that what is prescribed.
(ii) Class-B Fire :- There shall be at least one fire-extinguisher either, foam type or
carbon dioxide or dry power type per 50 square metres of floor area and shall be
so distributed that no person is required to travel more than 15 meters from any
point to reach the nearest equipment. In addition to the requirements,
extinguishers specified here, requirements as laid down in clause (1) shall also be
provided.
(iii) Class C Fire :- Carbon dioxide or dry chemical power extinguishers shall be
provided near each plant or group of plants.
(iv) Class D Fire :- Special dry power (Chloride based) type of extinguisher shall
be provided near each plant or group of plants depending upon the risk
involved.
(v) Class E Fire :- Carbon dioxide of dry power type extinguisher shall be
provided near each plant or group of plants depending upon the risk involved.
(d) The first-aid fire fighting equipments shall conform to the relevant Indian
Standards.
(e) As far as possible the first-aid fire fighting equipments shall all be similar in
shape and appearance and shall have the same method of operation.
(f) All first-aid fire fighting equipments shall be placed in a conspicuous position
and shall be readily and easily accessible for immediate use. Generally, these
equipments shall be placed as near as possible to the exits or stair landing of
normal routes of escape.
(g) All water buckets and pump type extinguishers shall be filled with clean
water. All sand buckets shall be filled with clean, dry and fine sand. All water
and sand buckets shall be painted red.
(h) All other extinguishers shall be charged appropriately in accordance with the
instructions of the manufacturer.
(i) Each first-aid fire-fighting equipment shall be allotted a serial number by
which it shall be referred to in the records. The following details shall be painted
with white paint on the body of each equipment :
(1) Serial number ;
(2) Date of last refilling ; and
(3) Date of last inspection.
(j) First-aid fire-fighting equipments shall be placed on platforms on cabinets in
such a way that their bottom is 750 mm above floor level. Fire buckets shall be
placed on books attached to a suitable stand or wall in such a way that their
bottom is 750 mm above the floor level. Such equipments if placed outside the
building, shall be under sheds or covers.
(k) All extinguishers shall be thoroughly cleaned and re-charged immediately
after discharge. Sufficient refill material shall be kept readily available for this
purpose at all times.
(l) All first-aid fire fighting equipments shall be subjected to routine
maintenance, inspection, and testing to be carried out by properly trained
persons. Periodicity of the routine maintenance, inspection and test shall
conform to the relevant Indian Standards.
(m) In case the fire is caused by electrical equipment, the connected switches be
pulled out.
(12) Other fire fighting arrangements : (a) In every factory adequate provisions of
water supply for fire fighting shall be made and where the amount of water
required in litres per minute as calculated from the formula A+B+C+D divided
by 20 in 550 or more, power driven trailer pumps of adequate capacity to meet
the requirement of water as calculated above shall be provided and maintained.
In the above formula:-
A - the total area in square meters of all floors including galleries in all buildings
of the factory :
B - the total area in square meters of all floors and galleries including open spaces
in which combustible materials are handed or stored :
C - the total area in square meters of all floors over 15 meters above ground level
; and
D - The total area of square meters of all floors of all buildings other than those of
fire resisting construction :
Provided that in area where the fire risk involved does not require use of water,
such areas under B, C or D may, for the purpose of calculation, be halved:
Provided further that where the areas under B, C or D are protected by
permanent automatic fire fighting installations approved by any fire association
or fire insurance company such areas may, for the purpose of calculation, be
halved:
Provided also that where the factory is situated at not more than 3 kilometers
from an established city or town fire service the pumping capacity based on the
amount of water arrived at by the formula above may be reduced by 25% but no
account shall be taken of this reduction in calculating water supply required
under this clause.
(b) Each trailer pump shall be provided with equipment as per scheduled
appended to this rule. Such equipment shall conform to the relevant Indian
Standards.
(c) Trailer pump shall be housed in a separate shed or sheds which shall be sited
close to a principal source of water supplies in the vicinity of the main risks for
the factory.
(d) In factories where the area is such as cannot be reached by man-hauling of
trailer pumps, within reasonable time, vehicles with towing attachment shall be
provided at the scale of one for every four trailer pumps with a minimum of one
such vehicle kept available at all times.
(e) Water supply shall be provided to give flow of water as required under clause
(a) for at least 100 minutes. At least 50% of this water supply or 450,000 litres
which ever is less, shall be in the form of static tanks of adequate capacities (not
less than 450,000 litres each) distributed round the factory with due regard to the
potential fire risks in the factory. Where piped supply is provided, the size of the
main shall not be less than 15 cms in diameter and it shall be capable of
supplying a minimum of 4,500 litres per minute at a pressure of not less than 7
kilograms per square centimetre.
(f) All trailer pumps including the equipment provided with -them and the
vehicles for towing them shall be maintained in good condition and subjected to
periodical inspection and testing as required.
(13) Personnel in charge of equipment and for fire fighting, fire drills, etc :- (a)
The first-aid and other fire fighting equipment to be provided as required in sub-
rules (11) and (12)shall be in charge of a trained responsible person.
(b) Sufficient number of persons shall be trained in the proper handling of fire-
fighting equipment as referred to in clause (a) and their use against number of
persons are available for fire fighting both by means of first-aid fire fighting
equipment and others. Such persons shall be provided with clothing and
equipment including helmets, belts and boots, preferably gumboots. Wherever
vehicles with towing attachment are to be provided as required in clause (d) of
sub-rule(11) sufficient number of persons shall be trained in driving these
vehicles to ensure the trained persons are available for driving them whenever
the need arises.
(c) Fire fighting drills shall be held at least once in every 3 months.
(14) Automatic sprinklers and fire hydrants shall be in addition and not in
substitution of the requirements in sub rules (11) and (12).
(15) If the Chief Inspector is satisfied in respect of any factory or any part of the
factory that owing to the exceptional circumstances such as inadequacy of water
supply or infrequency of the manufacturing process or for any other reason, to
be recorded in writing, all or any of the requirements of the rules are
impracticable or not necessary for the protection of workers, he may by order in
writing (which he may at his discretion revoke) exempt such factory or part of
the factory from all or any of the provisions of the rules subject to conditions as
he may by such order prescribe.
SCHEDULE
EQUIPMENT TO BE PROVIDED WITH TRAILER PUMP
For light trailer pump of a capacity of 680 litres / minute
1 Armoured suction hose of 9 m length, with wrenches.
1 Metal suction strainer.
1 Basket strainer.
1 Two-way suction collecting-head.
1 Suction adapter.
10 Unlined or rubber lined 70 mm delivery hose of 25 metres, length complete
with quick-release couplings.
1 Dividing breaching-piece.
2 Branch-piece with 15 mm nozzles.
1 Diffuser nozzle
1 Standpipe with blank cap.
1 Hydrant key.
4 Collapsible canvas buckets.
1 Fire hook (preventer) with cutting edge.
1 25 mm manila rope of 30 meters length.
1 Extension ladder of 9 m length (where necessary).
1 Heavy axe.
1 Spade.
1 Pick axe.
1 Crowbar.
1 Saw.
1 Hurricane lamp.
1 Electric torch.
1 Pair rubber gloves.
For large trailer pump of a capacity of 1800 litres/minute
Armoured suction hose of 9 m length, with wrenches.
Metal suction strainer.
Basket strainer.
Three-way suction collecting-head.
Suction adapter.
Unlined or rubber lined 70 mm delivery hose of 25 m, length complete with quick-
release couplings
Dividing breaching piece.
Collecting breaching-piece.
Branch pipes with one 25 mm two 20 mm and one diffuser nozzle.
Standpipes with blank caps.
Hydrant keys.
Collapsible canvas buckets.
Ceiling hook (preventer) with cutting edge.
50 mm manila rope of 30 m length.
Extension ladder of 9 m length (where necessary).
Heavy axe.
Spade.
Pick axe.
Crowbar.
Saw.
Hurricane lamp.
Electric torch.
A pair of rubber gloves
Note - If it appears to the Chief Inspector that in any factory the provision of
breathing apparatus is necessary he may by order in writing require the occupier
to provide suitable breathing apparatus in addition to the equipment for light
trailer pump or large trailer pump as the case may be.
62-A. Ovens and Driers
(1) Application:- This rule shall apply to ovens and driers, except those used in
laboratories or kitchens of any establishment and those which has a capacity
below 325 litres.
(2) Definitions:- For the purpose of this rule oven or drier means any enclosed
structure, receptacle, compartment or box which is used for baking, drying or
otherwise processing of any article or substance at a temperature higher than the
ambient temperature of the air in the room or space in which a flammable or
explosive mixture of air and a flammable substance is likely to be evolved within
the enclosed structure receptacle, compartment or box or part thereof on account
of the article or substance which is baked, dried or otherwise processed within it.
(3) Separate electrical connection :- Electrical power supplied to every oven or
drier shall be by means of a separate circuit provided with an isolation switch.
(4) Design, construction, examination and testing :- (a) Every oven or drier shall
be properly designed on sound engineering practice and be of good construction,
sound materials and adequate strength, free from any patent defects and safe if
properly used ;
(b) No oven or drier shall be taken into use in factory for the first time unless a
competent person has thoroughly examined all its parts and carried out the tests
as are required to establish that the necessary safe systems and controls provided
for safety in operation for the processes for which it is to be used and a certificate
of such examination and tests signed by that competent person has been
obtained and is kept available for inspection ; and
(c) All parts of an oven or drier which have undergone any alteration or repair
which has to effect of modifying any of the design characteristics, shall not be
used unless a thorough examination and tests as have been mentioned in clause
(b) have been carried out by a competent person and a certificate of such
examination and tests signed by that competent person has been obtained and is
kept available for inspection.
(5) Safety ventilation :- (a) Every oven or drier shall be provided with a positive
and effective safety ventilation system using one or more motor-driven
centrifugal fans so as to dilute any mixture of air and any flammable substance
that may be formed within the oven or drier and maintain the concentration of
the flammable substance in the air at a safe level of dilution ;
(b) The safe level of dilution referred to in clause (a) shall be so as to achieve a
concentration of the concerned flammable substance in air of not more than 25
per cent of its lower explosive limit :
Provided that a level of concentration in air up to 50 per cent of the lower
explosive limit of the concerned flammable substance may be permitted to exist
subject to installation and maintenance of an automatic device which-
(i) Shows continuously the concentration of the flammable substance in air
present in the oven or drier at any instant ;
(ii) Sounds an alarm when the concentration of the flammable substance in air in
any part of the oven or drier reaches a level of 50 per cent of its lower explosive
limit ; and
(iii) Shuts down the heating system of the oven or drier automatically when the
concentration in air of the flammable substance in any part of the oven or drier
reaches a level of 60 per cent of its lower explosive limit ;
is provided to the oven or drier and maintained in efficient working condition ;
(c) No oven or drier shall be operated without its safety ventilation system
working in an efficient manner;
(d) No oven or drier shall be operated with a level of dilution less than what is
referred to in clause (b) ;
(e) exhaust ducts of safety ventilation systems should be so designed and placed
that their ducts discharge the mixture of air and flammable substance away from
the workrooms and not near windows or doors or other openings from where
the mixture could re-enter the workrooms ;
(f) The fresh air admitted into the oven or drier by means of the safety ventilation
system shall be circulated adequately by means of circulating fan or fans through
all parts of the oven or drier so as to ensure that there are no locations where the
flammable substance can accumulate in the air or become pocketed to any
dangerous degree ; and
(g) Throttling dampers in any safety ventilation system should be so designed by
cutting away a portion of the damper or otherwise, that the system will handle at
least the minimum ventilation rate required for safety when they are set in their
maximum throttling position.
(6) Explosion panels :- (a) Every oven or drier having an internal total space of
not less than half cubic meter shall be provided with suitably designed explosion
panels so as to allow release of the pressure of any possible explosion within the
oven or drier through explosion vents. The area of openings to be provided by
means of such vents together with area of openings of any access doors which
are provided with suitable arrangements for their release in case of an explosion
shall be not less than 2200 square centimetre for every one cubic meter of volume
of the oven or drier. The design of the explosion panels and doors as above said
shall be much as to secure the complete release under the internal pressure of
0.25 Kg. per square centimeter ; and
(b) the explosion releasing panels, shall as far as practicable, be situated at the
roof of the oven or drier or at those portion of the walls where persons not
remain in connection with operation of the oven or drier.
(7) Interlocking arrangements :- (a) In each oven or drier efficient inter-locking
arrangements shall be provided and maintained to ensure that -
(i) all ventilating fans and circulating fans whose failure would adversely effect
the ventilation rate or flow pattern are in operations before any mechanical
conveyor that may be provided for feeding the articles to be processed in the
oven or drier is put into operation :
(ii) failure of any of the ventilating or circulating fans will automatically stop any
conveyor as referred to in clause (i) as may be provided, as well as stop the fuel
supply by closing the shut off valve and shut off the ignition in the case of gas or
oil fired oven and in the case of electrically heated ovens switch off the electrical
supply to the heaters;
(iii) the above said mechanical conveyor is not in operation before the above said
shut-off valve can be energized ; and
(iv) the failure of the above said conveyor will automatically close and above
said shut off value in the case of ovens and driers heated by gas, oil or steam and
reactivate the ignition system, or cut off the electrical heaters in the case of
electrically heated ovens or furnaces.
(8) Automatic preventilation :- Every oven or drier heated by oil, steam, gas or
electricity shall be provided with an efficient arrangement for automatic pre-
ventilation consisting of at least 3 volumes changes with fresh air by operation of
the safety ventilation fans and the circulating fans (if used) so as to effect purging
of the oven or drier of any mixture of air and a flammable substance before the
heating system can be activated and before the conveyor can be placed in
position.
(9) Temperature Control :- Every oven or drier shall be provided with an
automatic arrangement to ensure that the temperature within does not exceed a
safe upper present limit to be decided in respect of the particular processing
being carried on.
(10) Multistage processes :- Wherever materials are to be processed in ovens or
driers, start successive operations suitable arrangement should be provided to
ensure that the operating temperatures necessary for safe operation at each stage
are maintained within the design limits.
(11) Combustible substances not to drip on electrical heaters or burners flame :-
Effective arrangements shall be provided in every oven or drier to prevent
dripping of combustible substances on electric heaters or burner flame used for
heating.
(12) Periodical examination, testing and maintenance :- (a) All parts of every
oven and drier shall be properly maintained and thoroughly examined and the
various controls as mentioned in this rule and the working of the oven or drier
tested at frequent intervals to ensure its safe operation by a responsible person
designated by the occupier or manager, who by his experience and knowledge of
necessary precautions against risks of explosion is fit to undertake such works ;
and
(b) A register shall be maintained in which the details of the various tests carried
out from time to time under clause (a) shall be entered and every entry made
shall be signed by the person making the tests.
(13) Training of operators : No person shall be assigned any task connected with
operation of any oven or drier unless he has completed 18 years of age and he is
properly trained.
(14) Polymerising machines :-
(a) Printed fabric shall be thoroughly dried by passing them over drying cans or
through hot flue or other equally effective means, before the same is allowed to
pass through polymerising machines, and
(b) Infra red ray heaters of polymerising machines shall be cut-off while running
the prints.
62-B Safety Policy - (1) In every factory :-
(a) Wherein 250 or more workers are ordinarily employed ; or
(b) which carried on any process of operation declared to be dangerous under
section 87 of the Act ; or
(c) which carried on 'hazardous process' as defined under section 2(cb) of the Act
there shall be Safety Committee.
(2) The representatives of the management on Safety Committee shall include :
(a) A senior official, who by his position in the organisation can contribute
effectively to the functioning of the Committee, shall be the Chairman ;
(b) A Safety Officer and a Factory Medical Officer wherever available, and the
Safety Officer in such a case shall be the Secretary of the Committee ;
(c) A representative each from the production, maintenance and purchase
departments.
(3) The workers' representatives on the Committee shall be elected by the
workers,
(4) The tenure of the Committee shall be two years.
(5) Safety Committee shall meet as often as necessary but at least once in every
quarter. The minutes of the meeting shall be recorded and ; shall be produced to
the Inspector on demand. A copy thereof shall be sent to the Inspector of
Factories of the region concerned.
(6) Safety Committee shall have the right to be adequately and suitably informed
of -
(a) potential safety and health hazards to which the workers may be exposed at
work place.
(b) data on accidents as well as data resulting from surveillance of the working
environment and of the health of workers exposed to hazardous substances so
far as the factory is concerned, provided that the Committee under-takes to use
the data on measure to improve the working environment and the health and
safety of the workers.
(7) Function and duties of the Safety Committee shall include -
(a) assisting and co-operating with the management in achieving the aims and
objectives outlined in the 'Health and Safety Policy' of the occupier ;
(b) dealing with all matters concerning health safety and environment and to
arrive at practicable solutions to problems encountered ;
(c) creating safety awareness amongst all workers ;
(d) undertaking educational, training and promotional activities ;
(e) discussing reports on safety, environment and occupational health surveys,
safety audits, risk assessment, emergency and disaster management plans and
implementation of the recommendations made in the reports ;
(f) carrying out health and safety surveys and identify causes of accidents ;
(g) looking into any complaint made on the likelyhood of an imminent danger to
the safety and health of the workers and suggesting corrective measures; and
(h) reviewing the implementation of the recommendations made by it.
(8) Where owing to the size of the factory, or any other reason, the functions
referred to in sub-rule (7) can not be effectively carried out by the Safety
Committee, it may establish sub-committees as may be required to assist it.
CHAPTER IV-A
63-A- Site Appraisal Committee -
(1) Construction : The following provisions shall govern the functioning of the
Site Appraisal Committee, hereinafter referred to as the "Committee" in these
rules-
(a) the State Government may constitute or reconstitute the committee as and
when necessary ;
(b) the State Government may appoint a senior official of the Factories
Inspectorate preferably with qualification in Chemical engineering to be
Secretary of the Committee ;
(c) the State Government may co-opt the following persons as members of the
Committee ;
(i) a representative of the Fire Service Organisation of the State Government ;
(ii) a representative of the Department of Industries of the State Government;
(iii) a representative of the Director General of Factory Advice Service and
Labour Institute, Mumbai ;
(2) No member unless required to do so by a court of law shall disclose otherwise
than in connection with the purpose of the Act, at any time any information
relating to manufacturing or commercial business or any working process which
may come to his knowledge during his tenure as a member on the committee.
(3) Applications for appraisal of Sites- In respect of the factories covered under
section 2 (cb) of the Act shall be submitted to the Chairman of the Committee
along with 15 copies there of in form annexed to this rule. The committee may
dispense with the furnishing of the information on any particular item in the
application under consideration.
(4) Functions of the Committee -
(a) The Secretary shall arrange to register the applications received for appraisal
of site in a separate register and acknowledge the same within a period of 7 days.
(b) The Secretary shall fix up meeting in such a manner that all the applications
received and registered are referred to the Committee within a period of one
month from the date of their receipt.
(c) The Committee may adopt a procedure for its working keeping in view the
need for expeditious disposal of applications.
(d) The Committee shall examine the application for appraisal of a site with
reference to the prohibitions and restrictions on the location of industry and the
carrying on the processes and operations in different areas as per the provisions
of Rule 5 of the Environment (Protection) Rules, 1986 framed under the
Environment Protection Act, 1986.
(e) The Committee may call for documents examine experts, inspect the site, if
necessary, and take other steps for formulating its view in regard to the
suitability of the site.
(f) Wherever the proposed site requires clearance by the Ministry of Industry or
the Ministry of Environment and Forests of the Government of India site
appraisal will be considered by the Committee only after such clearance has been
received.
(g) No business shall be transacted to in any meeting unless at least five members
are present.
(5) Traveling Allowance - A non-official member of the Committee shall be
entitled to draw traveling and daily allowances for any journey performed by
him in connection with his duties as member of the Committee at the rates and
subject to the conditions laid down in rule 20 of Financial Handbook, volume -III.
Form of application to the Committee
(The information should be supplemented by enclosing copies documents, maps
or blue prints etc. wherever necessary)
1. Name and address of the applicant.
2. Site ownership Data.
2.1 Revenue details of site such as Survey number, plot number, Allotment
/Registration number etc.
2.2 Whether the site is classified as forest and if so, whether approval of the
Central Government under section 5 of the Indian Forests Act, 1927 has been
obtained.
2.3. Whether the proposed site attracts the provisions of section 3 (2) (V) of the
Environment Protection Act, 1986, if so, the nature of the restrictions.
2.4 Local authority under whose jurisdiction the site is located.
2.5. Documentary evidence of ownership.
3. Site Plan -
3.1. Site Plan with clear identification of boundaries and total area proposed to be
occupied and showing the following details nearby the proposed site -
(a) Historical monument, if any, in the vicinity.
(b) Names of neighbouring manufacturing units and human habitats,
educational and training institutions, petrol installations, storages of liquified
petroleum gas and other hazardous substances in the vicinity and their distances
from the proposed unit.
(c) Water sources (river, streams, canals, dams and water filtration plants etc.) in
the vicinity.
(d) Nearest hospitals, fire-stations, civil defence stations and police stations and
their distances from the proposed unit.
(e) High tension electrical transmission lines, pipelines for water, oil, gas or
sewerage : railway lines, roads, stations, jetties gas and other similar installations
in the vicinity.
3.2 details of soil conditions and depth at which hard strata obtained.
3.3 Contour map of the factory showing near by hillocks and difference in levels.
3.4 Plot plan of the factory showing the entry and exit points roads within, water
drains, etc.
4. Project Report -
4.1. A summary of the salient features of the project.
4.2. Status of the organisation (Government, Semi-Government, public or Private
etc.)
4.3. Maximum number of persons likely to be employed in the factory.
4.4. Maximum requirement of power and water and sources of their supply.
4.5. Block diagram of the buildings and installations, in the proposed unit.
4.6. Details of the proposed housing colony, hospital, school and other
infrastructural facilities.
5. Organisational structure for proposed manufacturing unit / factory.
5.1 Organisation diagram of -
- Proposed enterprise in general and.
- health, safety and environment protection departments and their linkage to
operation and technical department.
5.2. Proposed health and safety policy.
5.3. Area allocated for treatment of wastes and effluents.
5.4. Percentage of outlay on safety, health and environment protection measures.
6. Meteorological data relating to the site -
6.1. Average, minimum and maximum of -
- Temperature.
- humidity, and
- wind velocities.
during the previous ten years.
6.2. Seasonal variations of wind direction.
6.3. Highest water level reached during the floods in the area recorded so far.
6.4 Lightening and seismic data of the area.
7. Communication Links :
7.1. Availability of telephone /telex/wireless and other communication facilities
for outside communication.
7.2. Proposed internal communication facilities.
8. Manufacturing Process Information :
8.1. Process flow diagram in detail indicating process parameters, e.g.
temperature, pressure, etc. at various stages of manufacturing process or
processes.
8.2. Brief write-up on process and technology.
8.3. Critical process process parameters, such as pressure build-up, temperature
rise and runaway reactions.
8.4. Other external effects critical to the process having safety implications, such
as ingress of moisture or water, contact with incompatible substances, sudden
power failure.
8.5. Highlights of the built - in safety/pollution control devices or measures
incorporated in the manufacturing technology.
9. Information on Hazardous Materials :
9.1. Raw materials, intermediates, products and by-products and their quantities
(Enclose material safety data Sheet in respect of each hazardous substance).
9.2. main and intermediates, storages proposed for raw materials/
intermediates/ products (maximum quantities at any time to be stored).
9.3. Transportation methods to be used for inflow and outflow of materials their
quantities and likely routes to be followed.
9.4. Safety measures proposed for :
- handling of materials ;
- internal and external transportation ; and
- disposal (packing and forwarding of finished products.)
10. Information of Dispersal / Disposal of Wastes and Pollutants.
10.1. Major pollutants (gas, liquid, solid) their characteristics and quantities
(average and at peak loads).
10.2. Quality and quantity of solid wastes generated, methods of their treatment
and disposal.
10.3. Air, water and soil pollution problems anticipated and the proposed
measures to control the same, including treatment and disposal of effluents.
11. Process Hazards Information :
11.1. A copy of the report on environmental impact assessment be enclosed.
11.2. A copy of the report on Risk Assessment study be enclosed.
11.3. Published (open or classified) reports, if any on accident situations /
occupational health hazards or similar plants elsewhere (within or outside the
country).
12. Information of proposed safety and Occupational Health Measures.
12.1. Details of fire fighting facilities and minimum quantity of water,
Carbondioxide and/or other fire fighting measures needed to meet the
emergency.
12.2. Details of the proposed in house medical facilities.
13. Information on emergency Preparedness :
13.1. On-Site emergency plan and detailed disaster control measures.
13.2. Proposed arrangements, ; if any, for mutual aid scheme with the group of
neighbouring factories.
14. Any other relevant information :
I certify that the information furnished above is correct to the best of my
knowledge and nothing of importance has been concealed while furnishing it.
Signature of the Applicant
Applicant's full name and address.
63. B. Health and Safety Policy -
(1) The occupier of every factory, except as provided for in sub-rule (2), shall
prepare a written statement of his policy in respect of health and safety workers
at work.
(2) All factories -
(a) covered under section 2 (m) (i) but employing less than 50 workers.
(b) covered under section 2 (m) (i) but employing less than 100 workers.
are exempted from requirements of sub-rule (1) :
Provided that they are not covered under the First Schedule under section 2(cb)
or operations declared to be dangerous under section 87 of the Act.
(3) Not with standing anything contained in sub-rule (2), the Chief Inspector may
require the occupiers of any of the Factories or class or description of factories to
comply with the requirements of sub-rule (1), if, in his opinion, it is expedient to
do so.
(4) The Health and Safety Policy of the top management to health, safety and
environment and compliance with all the relevant statutory requirements ;
(b) Organisational set up to carry out the declared policy clearly assigning the
responsibility at different levels ; and
(c) arrangements for making the policy effective.
(5) In particular, the Policy should specify the following -
(a) arrangements for involving the workers ;
(b) intention of taking into account the health and safety performance of
individuals at different levels while considering their career advancement ;
(c) the responsibility of the contractors, sub-contractors, transporters and other
agencies entering the premises ;
(d) a resume of health and safety performance of the factory in its Annual
Report;
(e) relevant techniques and methods such as safety audits and risk assessment
for periodical assessment of the status on health, safety and environment and
taking all the remedial measures ;
(f) its intentions to integrate health and safety, in all decisions including those
dealing with purchase of plant, equipment, machinery and material as well as
selection and placement of personnel ;
(g) arrangements for informing, educating and training and retraining its
employees at different levels and the public, wherever required.
(6) A copy of the declared health and Safety Policy signed by the occupier shall
be made available to the Chief Inspector.
(7) The policy shall be made widely known by -
(a) making copies available to all workers including contract workers,
apprentices, transport workers, suppliers, etc.
(b) displaying copies of the policy at conspicuous places ; and
(c) any other means of communication ; in a language understood by the
majority of workers.
(8) The occupiers shall revise the Safety Policy as often as may be appropriate,
but it shall necessarily be revised under the following circumstances -
(a) Wherever any expansion or modification having implications on safety and
health of persons at works is made, or
(b) whenever new substances or articles are introduced in the manufacturing
process having implications in health and safety of persons exposed to such
substances or articles.
63 -C. Material Safety Data Sheet - Collection and development and
dissemination of information -
(I) The occupier of every factory carrying on a hazardous process shall arrange to
obtain or develop information in the form of Material Safety Data Sheet (MSDS)
in respect of every hazardous substance or material handled in the manufacture,
transportation and storage in the factory. It shall be accessible, upon request, to a
worker for reference -
(a) every such material Safety Data Sheet shall include the following information
-
(i) the identification mark used on the label ;
(ii) hazardous ingredients of the substance ;
(iii) physical and chemical characteristics of the hazardous substance ;
(iv) the physical hazards of the hazardous substance, including the potential for
fire, explosion and reactivity ;
(v) the health hazards of the hazardous substance, including signs and
symptoms of exposure, and any medical condition which are generally
recognised as being aggravated by exposure to the substance ;
(vi) the primary route or routes of entry ;
(vii) the permissible limits of exposure prescribed in the Second Schedule under
section 41-F of the Act, and in respect of a chemical not covered by the said
Schedule any exposure limit used or recommended by the manufacturer,
importer or occupier ;
(viii) any generally applicable precautions for safe handling and use of the
hazardous substance, which are known, including appropriate hygienic
practices, protective measures during repairs and maintenance of contaminated
equipment, procedures for clean up of spills and leaks ;
(ix) any generally applicable control measures, such as appropriate engineering
controls work practices, or use of personal protective equipment ;
(x) emergency and first-aid procedures ;
(xi) the date of preparation of the Material Safety Data Sheet, or the last change in
it ; and
(xii) the name, address and telephone number of the manufacturer, importer,
occupier or other responsible party preparing or distributing the Material Safety
Data Sheet, who can provide additional information on the hazardous substance
and appropriate emergency procedures if necessary.
(b) The occupier while obtaining or developing a Material Safety Data Sheet in
respect of a hazardous substance shall ensure that the information, recorded
accurately, reflects the scientific evidence used in making the hazard
determination. If he become newly aware of any significant information
regarding the hazards, the new information shall be added to the Material Safety
Data Sheet as soon as practicable.
(c) An example of such Material Safety Data Sheet is given in the Schedule to this
Rule Labelling :
(2) Every container of a hazardous substance shall be clearly labelled or marked
to identify :-
(a) The contents of the container ;
(b) The name and address of the manufacturer or importer of the hazardous
substances.
(c) the physical and health hazards ; and
(d) the recommended personal protective equipment needed to work safely with
the hazardous substance.
Schedule
MATERIAL SAFETY DATA SHEET
1. Chemical Identify :
--------------------------------------------------------------------------------------------
Chemical Name Chemical Classification
-------------------------------------------------------------------------------------------
Synonyms Trade Name
-------------------------------------------------------------------------------------------
Formula C. A. S. No. U. N. No.
-------------------------------------------------------------------------------------------
Regulated
Identification
Shipping Name
Codes/Label
Hazechem No.
--------------------------------------------------
Hazaradous Waste I.D. No.
Hazardous
Ingredients
C.A.S. No.
Hazaradous
Ingredients
C.S.A. No.
---------------------------------------------------- ----------------------------------------------------
1. 3.
---------------------------------------------------- ----------------------------------------------------
2. 4.
---------------------------------------------------- ----------------------------------------------------
2. Physical and Chemical Data
---------------------------------------------------------------------------------------------------------
Boiling Ragne / Point 0C Physical State Appearance
---------------------------------------------------------------------------------------------------------
Melting / Freezing
Point
0C
Vapour Pressure
Order @ 35^0 C mm
Hg
Odour
---------------------------------------------------------------------------------------------------------
Vapour Density (Air
= 1)
Solubility in Water
30^0 C mm Hg
Others
---------------------------------------------------------------------------------------------------------
Specific Gravity
Water = 1
pH
---------------------------------------------------------------------------------------------------------
3. Fire and Explosion
Hazard Data :
---------------------------------------------------------------------------------------------------------
Flammability Yes /
No
LEL % Flash point 0 C
Autoignition
Temperature^ 0 C
---------------------------------------------------------------------------------------------------------
TDG Flammability to
Impact
UEL % Flash point 0 C
Hazardous
Products of
combustion
---------------------------------------------------------------------------------------------------------
Explosion Sensitivity
to Impact
Explosion
Sensitivity to
Impact Static
Electricity
---------------------------------------------------------------------------------------------------------
Hazardous
Polymerisation
---------------------------------------------------------------------------------------------------------
Combustible Liquid
Explosive
Material
Corrosive Material
---------------------------------------------------------------------------------------------------------
Flammable Material Oxidiser Others
---------------------------------------------------------------------------------------------------------
Pyrophoric Material Organic Peroxide
---------------------------------------------------------------------------------------------------------
4. Reactivity Data :
---------------------------------------------------------------------------------------------------------
Chemical Stability
---------------------------------------------------------------------------------------------------------
Incompatibility with
other Materials
---------------------------------------------------------------------------------------------------------
Reactivity Hazardous
Products of Reaction
---------------------------------------------------------------------------------------------------------
5. Health Hazard
Data :
---------------------------------------------------------------------------------------------------------
Routes of Entry
Effects of Exposure /
Symptoms
---------------------------------------------------------------------------------------------------------
Emergency
Treatment
---------------------------------------------------------------------------------------------------------
TLV (ACGIH) ppm. mg/m3 STEL ppm.
Mg /
m3
------------------------------------------------------------------------------------------------------------
---
Permissible
Exposure limit
LD 50
ppm. mg/m3 Order
Threshold
ppm. LD
50
Mg /
m3
NFPA
Hazard Signals
Health Flammability Stability
Specia
l
---------------------------------------------------------------------------------------------------------
6. Preventive Measures :
---------------------------------------------------------------------------------------------------------
Personnel Protective Equipments
---------------------------------------------------------------------------------------------------------
Handling and Storage Precautions
---------------------------------------------------------------------------------------------------------
7. Emergency and First Aid Measure :
---------------------------------------------------------------------------------------------------------
Fire Fire Extinguishing Media
---------------------------------------------------------------------------------------------------------
Special Procedures
---------------------------------------------------------------------------------------------------------
Unusual Hazards
---------------------------------------------------------------------------------------------------------
Exposure First Aid Measures
----------------------------------------------------
Antidotes / Dosages
---------------------------------------------------------------------------------------------------------
Spills Steps to be taken
----------------------------------------------------
Waste Disposal Method
---------------------------------------------------------------------------------------------------------
8. Additional Information / References :
---------------------------------------------------------------------------------------------------------
---------------------------------------------------------------------------------------------------------
---------------------------------------------------------------------------------------------------------
---------------------------------------------------------------------------------------------------------
---------------------------------------------------------------------------------------------------------
---------------------------------------------------------------------------------------------------------
9. Manufacturer / Suppliers Data :
---------------------------------------------------------------------------------------------------------
Contact Person in Emergency
----------------------------------------------------
Name of Firm Mailing Address
Telephone / Telex nos. Telegraphic
Address
Local Bodies involved
----------------------------------------------------
Standard Packing
----------------------------------------------------
Tremeard Details / Reference
----------------------------------------------------
Others
---------------------------------------------------------------------------------------------------------
10. Disclaimer :
---------------------------------------------------------------------------------------------------------
--------------------------------------------------------------------------------------------------------
Information contained in this material data sheet is believed to be reliable but no
representation, guarantee or warranties of any kind are made as to its accuracy,
suitability for a particular application of results to be obtained from them. It is up
to the manufacturer / seller to ensure that his information contained in the
material Safety data sheet is relevant to the product manufactured / handled or
sold by him as the case may be. The Government marks no warranties expressed
or implied in respect of the adequacy of this document for any particular
purpose :
63-B. Health and Safety Policy
63-D - Disclosure of information to the workers -
(1) The occupier of every factory carrying on a hazardous process supply to all
workers the following information in relation to handling of hazardous materials
or substances in the manufacture, transportation, storage and other processes :-
(a) requirements of Section 41B, 41-C and 41H of the Act ;
(b) a list of hazardous processes carried on in the factory ;
(c) location and availability of all Material Safety Data Sheets as per Rule 63 - C.
(d) Physical and health hazards arising from the exposure to or handling or,
substances ;
(e) measures taken by the occupier to ensure safety and control of physical and
health hazards ;
(f) measures to be taken by the workers to ensure safe handling, storage and
transportation of hazardous substances ;
(g) personal protective equipment required to be used by workers employed in
hazardous process of dangerous operations ;
(h) meaning of various labels and markings used on the containers of hazardous
substances as provided under Rule 63 - C ;
(i) signs and symptoms likely to manifest on exposure to hazardous substances
and to whom to report ;
(j) measures to be taken by the workers in case of any spillage or leakage of a
hazardous substance ;
(k) role of workers vis-a-vis the emergency plan of the factory, in particular the
evacuation procedures ;
(l) Any other information considered necessary, by the occupier to ensure safety
and health of workers.
(2) The information required by sub-rule (1) shall be complied and made known
to workers individually through supply of booklets or leaflets and display of
cautionary notices at the work places.
(3) The booklets, leaflets and the cautionary notices displayed in the factory shall
be in the language understood by the majority of the workers and shall also be
explained to them.
(4) The Chief Inspector may direct the occupier to supply further information to
the workers as deemed necessary.
63 -E - Disclosure of information to the Chief Inspector :-
(1) The occupier of every factory carrying on a hazardous process shall furnish,
in writing, to the Chief Inspector a copy of all the information furnished to the
workers.
(2) A copy of compilation of Material Safety Data Sheets in respect of hazardous
substances used, produced or stored in the factory shall be furnished to the Chief
Inspector and the local Inspector.
(3) The occupier shall also furnish any other information asked for by the Chief
Inspector from time to time for the purpose of the Act and the Rules made there-
under.
63 -F - Information on industrial wastes :-
(1) The information furnished under rules 63-D and 63-E shall include the
quantity of the solid and liquid wastes generated per day their characteristic s
and the methods of treatment such as incineration of solid wastes, chemical and
biological treatment of liquid wastes, and arrangements for their final disposal.
(2) It shall also include information on the quality and quantity of gaseous waste
discharge through the stacks or other openings and arrangements such as
provisions of scrubbers, cyclone separators, electrostatic precipitators of similar
such arrangements made for controlling pollution of the environment.
(3) The occupier shall also furnish the information prescribed in the sub-rule (1),
and
(2) to the State Pollution Control Board.
63 -G. Review of the Information furnished to workers:-
(1) The occupier shall review once in every Calendar year and modify, if
necessary, the information furnished under Rules 63-D and 63-E to the workers
and the Chief Inspector.
(2) In the event of any change in the process or operations or methods of work or
when any new substance is introduced in the process or in the event of a serious
accident taking place the information so furnished shall be reviewed and
modified to the extent necessary.
63 -H - Confidentiality of information :-
The occupier of a factory carrying on a 'hazardous process", shall disclose all
information needed for protecting safety and health of the workers to -
(a) his workers, and
(b) Chief Inspector,
as required under rules 63-D and 63-E if the occupier is of the opinion that the
disclosure of details regarding the process and formulations will adversely affect
his business interests, he may make a representation to the Chief Inspector
stating the reason for with holding such information. The Chief Inspector shall
pass an order on the representation after giving an opportunity to the occupier of
being heard.
(2) An occupier aggrieved by an order of the Chief Inspector may prefer an
appeal to the State Government within a period of 30 days and the State
Government may after giving an opportunity to the occupier of being heard shall
pass order and the order of the State Government shall be final.
Medical Examination :-
(1) Workers employed in a 'hazardous process' shall be medically examined by a
qualified medical practitioner, hereinafter referred to a Factory Medical Officer,
in the following manner -
(a) once before employment, to ascertain physical fitness of the person to do a
particular job ;
(b) once in a period of 6 months, to ascertain the health status of all the worker in
respect of occupational health hazards to which they are exposed, and at a
shorter interval in respect of a worker in whose case the Factory Medical Officer
is of the opinion that it is necessary to do so ;
(c) the details of pre-employment and periodical medical examinations carried
out as aforesaid shall be recorded in the Health register in Form 27.
(2) No person shall be employed for the first time without a certificate of fitness
in Form 26, granted by the Factory Medical Officer, if the Factory Medical Officer
declares a person unfit for employment in a process covered under sub-rule (1)
he shall have the right of appeal to the Inspector who shall refer the matter to the
Certifying Surgeon appointed under sub-section (1) or authorised under sub-
section (2) of section 10 of the Act whose opinion shall be final in this regard. If
the Inspector is also a Certifying Surgeon, he may dispose of the application
himself.
(3) Any finding of the Factory Medical Officer revealing any abnormality or
unsuitability of any person employed in the process shall, inturn, examine the
concerned worker and communicate his findings to the occupier within 30 days.
If the Certifying Surgeon is of the opinion that the worker so examined is
required to be taken away from the process for health protection, he will direct
the occupier accordingly, who shall not employ the said worker in the same
process. However, the worker so taken away shall be provided with alternative
placement unless he is in the opinion of the Certifying Surgeon fully
incapacitated in which case the worker affected shall be suitably rehabilitated.
(4) A Certifying Surgeon on his own motion or on a reference from an Inspector
may conduct medical examination of a worker to ascertain the suitability of his
employment in a hazardous process or for ascertain his health status. The
opinion of the Certifying Surgeon in such a case shall be final. The requisite fee
for this medical examination shall be paid by the occupier.
(5) The worker taken away from employment in any process under sub-rule (2)
may be employed again in the same process only after obtaining the Fitness
Certificate from the Certifying Surgeon and after making entries to that effect in
the Health Register.
(6) The worker required to undergo medical examination under these rules and
for any medical survey conducted by or on behalf of the Central or the State
Government shall not refuse to undergo such medical examination.
63 -J. Occupational Health Centers -
(1) I respect of any factory carrying on 'hazardous process' there shall be provide
and maintained in good order an occupational Health Center with the services
and facilities as per scale laid down hereunder :
(a) for factories employing up to 50 workers -
(i) the services of a Factory Medical Officer on retainer ship basis in his clinic to
be notified by the occupier. he will carry out premployment and periodical
medical examinations as stipulated in rule 63-I and render medical assistance
during an emergency.
(ii) a minimum of 5 persons trained in first aid procedures of whom at least one
shall always be available during the working period.
(iii) a fully equipped first aid box in all the departments.
(b) for factories employing 51 to 200 workers -
(i) an Occupational Health Center having a room with a minimum floor area of
15 square metre with floors and walls made of smooth and impervious surface
and with adequate illumination and ventilation as well as equipment as per the
Schedule annexed to this rule ;
(ii) a part time factory Medical Officer shall be in over all charge of the Center
who shall visit the factory at least twice in a week and whose services shall be
readily available during medical emergencies.
(iii) one qualified and trained dresser-cum-compounder on duty through out the
working period ;
(iv) a fully equipped first aid box in all departments.
(c) for factories employing above 200 workers -
(i) one full-time Factory Medical Officer for factories employing up to 500
workers and one more Medical Officer for every additional 1000 workers or part
thereof ;
(ii) an occupational Health Center having at least two rooms each with a
minimum floor area of 15 square metre with floors and walls made of smooth
and impervious surface and adequate illumination and ventilation as well as
equipment as per the Schedule annexed to this rule ;
(iii) there shall be one nurse, one dresser-cum-compounder and one sweeper-
cum-wardboy throughout the working period ;
(iv) the Occupational Health Center shall be suitably equipped to manage
medical emergencies.
(2) The Factory Medical Officer required to be appointed under sub-rule (1) shall
have qualifications included in Schedule to the Indian Medical Degrees Act, 1916
or in the Schedule to the Indian Medical Council Act, 1956 and possess a
Certificate of Training in Industrial Health of a minimum of three months
duration recognised by the State Government Provided that -
(i) a person possessing a Diploma in Industrial Health or its equivalent shall not
be required to possess the certificate of training as aforesaid ;
(ii) the Chief Inspector may, subject to such conditions as he may specify, grant
exemption from the requirement of this sub-rule, if in his opinion a suitable
person possessing the necessary qualification is not available for appointment ;
(iii) in case of a person who has been working as a Factory Medical Officer for a
period of not less than three years on the date of commencement of this rule, the
Chief Inspector may, subject to the condition that the said person shall obtain the
aforesaid certificate of training within a period of three years, relax the
qualification.
(3) The syllabus of the course leading to the above certificate, and the
organisations conducting the course shall be approved by the Directorate
General of Factory advice Service and Labour Institutes or the State Government
in accordance with the guidelines issued by the Directorate General of Factory
Advice Service and Labour Institutes.
(4) Within one month of the appointment of Factory Medical Officer, the
occupier of the Factory shall furnish to the Chief Inspector the following
particulars :
(a) Name and address of the Factory Medical Officer,
(b) Qualifications,
(c) Experience, if any, and
(d) The sub-rule under which appointed.
SCHEDULE
Equipment for Occupational Health Centre in Factories :
1. A glazed sink with hot and cold water always available.
2. A table with a smooth top of at least 180 cm x 105 cm.
3. Means for sterilizing instruments.
4. A couch.
5. Two buckets or containers with closely fitting lids.
6. A kettle and spirit stove or other suitable means of boiling water.
7. One bottle of spiritus amoniac aromatics (120 ml.)
8. Two medium sizes sponges.
9. Two 'Kidney' trays.
10. Four cakes of toilet soap, preferably antiseptic, soap.
11. Two glass tumblers and two wine glasses.
12. Two clinical thermometers.
13. two tea spoons.
14. two graduated (120 ml.) measuring glasses.
15. One wash bottle (1000 cc) for washing eyes.
16. One bottle (one litre) carbolic lotion in 20.
17. Three chairs.
18. One screen.
19. One electric hand torch.
20. An adequate supply of tetanus toxoid.
21. Coramine liquid (60 ml.)
22. Tablets -antihistaminic, antispasmodic (25 each).
23. Syringes with needles-2 cc and 10 cc.
24. Two needle holders, big and small.
25. Suturing needles and materials.
26. One pair of dressing forceps.
27. One pair of dressing forceps.
28. One scapel.
29. One stethescope.
30. Rubber bandage-pressure bandage.
31. Oxygen cylinder with necessary attachments.
32. One blood pressure apparatus.
33. One pateller Hammer.
34. One Peak-flow meter for lung function measurement.
35. One stomach wash set.
36. Any other equipment recommended by the Factory Medical Officer
according to specific relating to manufacturing process.
37. In addition -
(a) for factories employing 51 to 200 workers :
1. four plain wooden splints of 900 mmx100mmx6mm ;
2. four plain wooden splints of 350 mmx75mmx6mm ;
3. two plain wooden splints of 250 mmx50mmx12mm ;
4. one pair of artery forceps ;
5. injections-morphia, pethidine, atropine, adrenaline, coramine, novacan (2
each): and
6. one pair of surgical scissors;
(b) For factories employing above 200 worker :
1. eight plain wooden splints of 900 mmx100mmx6mm ;
2. eight plain wooden splints of 350 mmx75mmx6mm ;
3. four plain wooden splints of 250mmx50mmx12mm ;
4. two pairs of artery forceps ;
5. Injection-morphia, pethidine, atropine, adrenaline, coramine, novocan (2 each)
; and
6. two pairs of surgical scissors.
63 -K. Ambulance Van. -
(1) In every factory carrying on a 'hazardous process' there shall be provided and
maintained in good condition, a suitably constructed ambulance van equipped
with items as per sub-rule (2) and manned by a full time Driver-cum-Mechanic
and a Helper trained in first aid, for the purposes of sickness. The ambulance van
shall not be used for purposes other than the purpose stipulated herein and will
normally be stationed at or near the occupational Health Centre :
Provided that a factory employing less than 200 workers may make
arrangements for procuring such facility at a short notice from a nearby hospital
or other places to meet emergency.
(2) The ambulance van should have the following equipment :
(a) General :
As wheeled stretcher with folding and adjusting devices ; with the head of the
stretcher capable of being titled upward ;
- fixed suction unit with equipment ;
- fixed oxygen supply with equipment ;
- pillow with case ; sheets ; blankets towels ;
- emesis bag, bed pan ; urinal ; glass ;
(b) Safety equipment :
- flares with life of 30 minutes ; flood lights ;
- flash light ; fire extinguisher-dry powder type ;
- insulated gauntlets.
(c) Emergency Care Equipment :
(i) Resuscitation -
- portion suction unit ; portable oxygen unit ;
- bag - valve-mask, hand operated artificial ;
- ventilation unit ;
- airways ; mouth bags ; tracheetomyadapters ;
- short spine board ; I. V. fluids with Administration unit ;
- B. P. manometer ; Cugg ; stethescope ;
(ii) Immobilization -
- long and short padded boards wire ladder splints ;
- triangular bandage ; long and short spine boards.
(iii) Dressings -
- gauze pads -4"x4" universal dressing 10"x36" ;
- roll of aluminium foils ; soft roller bandages 6"x5" Yards ; adhesive tape in 3"
roll ; safety pins ;
- bandage sheets ; burn sheet ;
(iv) Poisoning -
- syrup of Ipecae ; activated Charcoal prepacketed in doses ; snake bite kit ;
- drinking water ;
(v) Emergency medicines -
- as per requirement (under the advice of Medical Officer only)
63 -L. Decontamination facilities -
In every factory carrying out hazardous process the following provisions shall be
made to meet an emergency ;
(a) fully equipped first aid box ;
(b) readily accessible means of water for washing by workers as well as for
drenching of clothing of workers who have been contaminated with hazardous
and corrosive substance ; and such means shall be as per the scale shown in the
table below :
Number of person employed at any
time
Number of drenching showers
(i) Upto 50 workers 2
(ii) Between 51 and 200 workers. 2+1 for every additional 50 or part thereof
(iii) Between 201 and 500 workers
5+1 for every additional 100 or part
thereof
(iv) 501 workers and above.
8+1 for every additional 200 or part
thereof.
(c) a sufficient number of eye wash bottles filled with distilled water or suitable
liquid, kept in boxes or cupboards conveniently placed and clearly indicated by a
distinctive sign which shall be easily available at all times.
63 -M. Making available health records to workers -
(1) The occupier of every factory carrying out a "hazardous process" shall make
accessible the health records ; including the record of worker's exposure to the
hazardous process or, as the case may be, the medical records of any worker for
his perusal under the following conditions :
(a) once in every six months or immediately after the medical examination
whichever is earlier ;
(b) if the Factory Medical Officer or the Certifying Surgeon, as the case may be, is
of the opinion that the worker has manifest signs and symptoms of any
noticeable disease as specified in the third Schedule to the Act ;
(c) if the worker leaves the employment ;
(d) if any one of the following authorities, so direct -
- the Chief Inspector of Factories ;
- the Health Authority of the central or State Government ;
- Commissioner of workmen's Compensation ;
- the Director General, Employees' State Insurance Corporation ;
- The Director, Employees State Insurance Corporation (Medical Benefits) ; and
- the Director General, Factory Advice Service and labour Institute.
(2) A copy of the upto date health records including the record of workers expo-
sure to hazardous process or, as the case may be, the medical records, shall be
supplied to the worker on receipt of an application from him. X-ray plates and
other medical diagnostic reports may also br made available for reference to his
medical practitioner.
63 -N. Qualification, etc. of Supervisors :-
(1) All persons who are required to supervise the handling of hazardous
substances shall possess the following qualification and experience -
(a) (i) a degree in Chemistry or Diploma in Chemical Engineering or Technology
with five years experience ; or
(ii) a Master's Degree in Chemistry or a degree in Chemical Engineering or
Technology with two Years experience;
The experience stipulated above shall be in process operation and maintenance
in a chemical industry ;
(b) the Chief Inspector may require the supervisor to under go training in Health
and Safety.
(2) The syllabus and duration of the above training and the organisations
conducting the training shall be approved by the Director General, Factory
Advice Service and Labour Institutes or the State Government in accordance
with guidelines issued by the Director general, Factory Advice Service and
Labour Institutes.
63 -O. Issue of guidelines :-
For the purposes of compliance with the requirements of sub-sections (1), (4) and
(7) of section 41-B or of section "41-C the Chief Inspector may , if deemed
necessary, issue guidelines from time to time to the occupiers of factories
carrying on 'hazardous process'. Such guidelines may be based on national
standards, Code of practice or recommendations of international bodies such as
International Labour Organisation and World Health Organisation."
CHAPTER V
Washing facilities (Section 42)
Previous and next
Questions people ask
Is rule 60 of Uttar Pradesh Factory Rules, 1950 still in force?
No repeal of Uttar Pradesh Factory Rules, 1950 is recorded.