Regulation 39, Indian Boiler Regulations, 1950.: Flattening Test

Indian Boiler Regulations, 1950. - Regulation 39

Text of regulation 39

Flattening Test

39. Flattening Test.—A ring not leas than 2 inohe* in length out from one end of each selected tube shall be flattened between two parallel flat surfaces, the width ofwhioh shall be not less than 1£ times tho diameter of the tube. When the pres- sure is released, the interior surfaces of tho lent piece (at the middle) shall remain at the following distances apart and the tent piece shall then show no sign of oraok or flaw. Tuboa over 10 3.W.G. in thieknrww TuboB up to and including 10 S.W.C1. in thickness. N't it THoro than twice the thicknem of the tube. Until the interior surfaces meet, at th» middle