Form VI, Indian Boiler Regulations, 1950.: FORM VI

Indian Boiler Regulations, 1950. - Form VI

Text of form VI

FORM VI

FORM VI BOILER INSPECTION DEPARTMENT CERTIFICATE FOH USE OT A BOILER (Regulation 3S9) Registry Number of Boiler. Type of Boiler. Boiler Rating, Place and yoar of manufacture. Maximum Continuous Evaporation. Name of Owner. Situation of Boiler. Repairs, Remarks. Hydraulically Tested on to lbs. per sq. inch. I hereby oertify that the above described boiler ie permitted by me/tho Chief Innpeotor under tho provisions of Section 7/8 of the Indian Boilers Act-, No. V of 1923, to be worked at a maximum pressure of lbs. to the square inch for the period from to The loading of tho Hafety valve is not to exceed I furthor oertify that the main steam pipe wan tested bydraulically to a pressure of lbs, per square inch last on Fee Ra. paid on Dated at This day of 10 InBpeotor. Countersigned. Chief Inspector. See Reverse for "conditions" CONDITIONS (Reverse ot Form VI) (1) No atruotural alteration, addition or renewal ahall be mado to the boiler otherwise thon in accordance with Section 12 of the Aot. (2) Under the provisions of Seotion 8 of the Aot this certificate sha Tocaae to be in force:— (a) on the expiry of the period for whloh it w is granted j or (6) when any aooident OCOUTH to the bailor , or (c) whon the boiler 1B moved, the boiler not being a vertical boiler the heating surfaoe^of which is less than two hundred square feet, or a portable or vehicular boiler; or (d) when any structural alteration, addition or renewal is made in or to the boiler ; or («) if the Chief Inapeotor in any particular oase so directs when any structural alteration, addition or renewal is made in or to any steam pipe attached to the boiler j or (/) on the communication to the owner of the boiler of an order of tho Chief Inspector or Inspeotor prohibiting its use on the ground that it or any atoam pipe attaohed thereto ia in a dangerous condition. Under Seotion 10 of the Aot a boiler may continue to be worked beyond the period of the certificate issued for it provided the ownoi has applied for a renewal of the certificate before the expiry date trad none of the coses specified in clauses (6), (o), (d), (e) and (/) apply to the boiler, (3) The boiler shall not be used at a pressure greater than the pressure entered in the certi- ficate n« the maximum pressure nor with the safely valve Bet to a pressure txoeeding such maxi- mum pressure. (4) The boiler shall not be used otherwise than in a oondition whioh the owner reasonably believe* to be compatible wjth safe working. N.B —Details regarding this boiler are recorded in Registration Book No. . of which a copy may be obtained on payment on application to the Chief Inspector FORM vn " INSPECTING AUTHORITY'S CERTIFICATE OF INSPECTION UNDER CONSTRUCTION DESIGNATION OF INSPECTING AUTHORI1Y [Reg. 601 (o)] We hereby certify that type, Eoonomiser, consisting of sections, and tubes to each seotion was construc- ted for a working pressure of lbs. by Messrs under our supervision and inspected at various stages of construction by tho Inspecting Offloer and that the construction and workmanship were satisfactory and in accordance with the standard conditions for the design and construction of Economiser laid down in Chapter XI of the Indian Boiler Regulations, 1950. Identification maik on each section, Branch Pipe or other pressure par!. Position of some. The soctions on completion were subjected to a water prossuie of lbs per eq in. for ten minutes in tho presonoe of the Inspecting Offloer on imd satisfactorily withstood the test Samples of the matenal used in tho constructions of tho Eoocommer were tested in the pro. eenoe of (he Inspecting Officer and were found to comply with tho testR prescribed m Chapter XI of tho Indian Boiler Regulations, I960. We have satisfied ourselves that tho constiuotion and dimensions of the Eoonomiser are t aa shown in the Makers' drawing No. signed by us and that the partioulais entered In the Makers' oertifloate of manufacture m Form V1I1 countersigned by us are correot to tho beat of our knowledge and belief. Dated at this day of 19 Signature ot Inspecting Authority. FORM vm Works Address CONSTRUCTOR'S CERIIFICATE OF MANUFACTURE AND TEST [Rpg 601 (d)) 1. Description Typo of Eoonomiser No. of Seotiong Intondod working pressure Year of manufacture Description. No. of tube' lbs Total hoating surface ol tubes 2. Inspecting Authority . Economiser constructed under super- vision of Sections hydraulioally tested for mlnutefl and Inipooted after test by 3. Construction and work- manship. Dotaila aro in Drawing No. All castings euvt well finished, free from external defect?, porous places and blow-holea and true to dimensions without warping. Whoro chapleta aro used, thero is satisfactory fusion with tho metal. Chapleta are properly tinned with metal free from load. All ecrow threads we of British Standard Whitworth form. AH component ports aro manufactured to limit gaugoa to secure intorohangeability throughout. 4. Eoonomiaer and fitting* Parts Material Maker Inapocting Offloar Remarks Particulars of material used Headers Tubes and or Pipes Valvo ohoatf) Bolta THICKNESS OF PARTS AND TENSILE TEST LIMITS 5. Part o Economlsor Hoaders Tuboa Boltu Thioknoaa in 32nds Tensile strength limits to tons Elongation limits t o % Gauge length Brand and No. Certified that the particulars ontored horein are correct and that tho parta and flttinga men. tionad abovo have boon usod in the construction and fittings of tho Eoonomiaer. The particulars shown against tho vttfious ptvrts uaod aro in accordance with tho Maker's certi- ficates m our possession. Tho depign of the oconomisor in section and ond viuw with principal parts fully dimensioned is that shown in drawing No. Tho Economiaer has been dosignod and cons- tructed to comply with the Indian Boilnr Rogulationa for a working of lbs- por aq. in., at our Worka abovemontioned and tho aoctions satisfactorily witliatood a water test of lb^. pur sq. in. for minutes on day of in the presence of our roaponsiblo representative svhow signature ia appended lioroundor. Dosignation of Makor Signature of Engineer who witnessed tho test. Dated at thia day of 19 Signature of the Inspecting Authority. NOTB.—The drawing of tho Economiser and Makor'a certificate of manuftwture showing result* of teats for tensile strength and elongation must acoompany this certificate and if the oconomiaer has boon built undor tho supervision of an Inspecting Authority thoir oortincate in Form VII mu»t aooompany.

Previous and next

All provisions of Indian Boiler Regulations, 1950.

Questions people ask

Is form VI of Indian Boiler Regulations, 1950. still in force?

No repeal of Indian Boiler Regulations, 1950. is recorded.