LawGrids logoLAWGRIDS.ORG

Form D, Energy Conservation ( Norms and standards for Designated Consumers Form, Time within which, manner of preparation and implementation of scheme, procedure for issue of energy saving certificates and value of per metric ton of oil equivalent of energy consumed ) Rules, 2018: Form-D

Energy Conservation ( Norms and standards for Designated Consumers Form, Time within which, manner of preparation and implementation of scheme, procedure for issue of energy saving certificates and value of per metric ton of oil equivalent of energy consumed ) Rules, 2018 - Form D

Text of form D

Form-D

Form-D c. Balance Energy Savings Certificates L__ b Energy Savings Certificates submitted for compliance Energy Savings Certificates Performance Assessment Submitted/Not Document (Form 'A') Submitted Compliance Date of Submission Note 1: Form D may be filled in accordance with the following guidelines:- GUIDELINES 1. Name of designated consumer: As per notification from Government of India (Gol) under clause (g) of section 14 2. Registration number: As per E-filing 3. Sector: • Aluminium • Cement • Chlor Alkali • Fertilizer • Iron and Steel • Pulp and Paper • Textile • Thermal Power Plant 1178G/2012-11 If recommended for purchase Nos Issued/Recommended for purchase 4. Sub Sector: [PART II—Sec. 3(i)] I THE GAZE I I E OF INDIA : EXTRAORDINARY Si-119-$.ectQi:!..-i„: 6 poweerweit Fuel B6S6a ' '-'''N'I`T' Gas, Oil Cement rfbn.inid eeI CVer on 06ed rr* - -It grate* -- Fertilizer Feedstock Based Natural Gas, Naptha Pulp ancII'ae!L Wood,A2ro, RCF Raw Material Based Chlor-Alkali Technology Based 5. List of Documents submitted: (a) Performance assessment document: Submitted to Bureau of Energy Efficiency for issue of energy savings certificates. 6. Compliance Process Based Dr Wet Tektile " dsed- '13151iiiiihg -Processing , v COrfIVP44e, Fiber yarn Membrane cell, Mercury Smelt ud (a) Energy savings certificates: Enter +ve value if energy savings certificates issued to designated consumer or enter -ye value in case recommended for purchase of energy savings certificates (b) Energy savings certificates submitted for compliance: If designated consumer is recommended for purchase of energy savings certificates, then enter value of energy savings certificates submitted by designated consumer for compliance of energy consumption norms and standards- saving target of designated consumer. (c) Balance energy savings certificates:- Numbers of energy savings certificates balance. If balance is ZERO than DC is in accordance for compliance of energy saving target and if balance is -ve than DC will be recommended for penalty. Undertaking I/VVe undertake that the information supplied in compliance with energy consumption and standard documents in this Form 'D' is accurate to the best of my/our knowledge and if any of the information supplied is found to be incorrect and such information result into loss to the Central Government or State Government or any of the authority under them or ar:: other person affected, I/we undertake to indemnify such loss. I/we agree to extend necessary assistance in case of any enquiry is made in the matter Signature Name Designation For and behalf of Name of the Firm/Company!Organisation SEAL of the Firm/Company/Organisation 4TR-ff ,(1.14 : 3-mmtvi 83 [ iTrri II—cgu.s 3(i)] Schedule [See rules 2, 4 and 7] 1. Determination of baseline specific energy consumption.- 1.1 Specific energy consumption (See rule 2(1)) (a) The specific energy consumption (SEC) gives the indication of efficient utilisation of different sources of energy in a plant operational boundary to produce one unit of product, which is defined as the ratio of total energy input to plant boundary and the quantity of products produced and specific energy consumption of an industry shall be calculated based on Gate-to-Gate concept with the following formula:- Specific Energy Consumption = Net energy input into the designated consumers' boundary Total quantity of output exported from the designated consumers' boundary and expressed in terms of the metric ton of oil equivalent (toe)/per unit of product; Note: value to be rounded to three decimal places. Table 1: Definition of product to calculate specific energy consumption . Se cto r* ' Cement Main product Unit Cement ton Fertilizer Urea ton ton Iron and Steel (Integrated) Crude keel iron and Steel (Sponge Iron) Sponge Iron ton Aluminium (Refinery) Aluminium (Smelter) Alumina Molten Aluminium ton ton Aluminium (Integrated) Molten Aluminium ton Pulp and Paper (Pulping) Pulp Paper ton ton Pulp and Paper (Only Paper Making) i- Pulp and Paper (Pulp and Paper) Paper ton Textile (Spinning) Textile (Composite) Yarn Yarn/Fabric ..._..... Kg kg Textile (Fibre) Fibre kg Textile (Processing) Fabric kg Chlor-Alkali Equivalent Caustic Soda ton Power- Plant Million k4h Electricity icity (10.NH) Furnace oil (Liter) Natural gas (SCM) Coo! (KG) X ( kwh) • SFC (kwh/ltr) Process Others (KG of Ltr) ►r DG A (Ltr) Product (Kg) • I4 THE GAZETTE OF INDIA : EXTRAORDINARY [PART 3(i)I 1.2 Gate-to-Gate designated consumer boundary (sector-specific) (a) As the specific energy consumption (SEC) is calculated on a Gate-to-Gate concept, the plant boundary shall be selected in such a manner that the total energy input and the above product defined in Table 1, is be fully captured and the entire designated consumers' plant The colony, residential complex and transportation system, mining operations in case of Iron and Steel, Aluminum and Cement sectors are not part of designated consumers 'boundary. (b) Once the 'designated consumers' boundary has been fixed, the same boundary shall be considered for entire cycle, and any change in the said boundary such as capacity expansion, merger of two plants, division of operation etc. shall be duly intimated to the Bureau of Energy Efficiency. (c) The following designated consumers' boundaries will be considered in the first cycle:- Case -I: All energy purchased and consumed:- • Electricity is purchased from the grid Electricity (kWh) 0.1 Furnace Oil (Liter) Product (Kg) Natural Gas (SCM) Process • Coal (KG) Others (Kg or Ltr) C se -II: Electricity partially generated by diesel generating(DG) set ,other energy purchased and consumed:- • Electricity is purchased from the grid and generated by DG set G (KWH) CPP Y (KWH) to Grid 1 Aux P (a%) X (KWH) A Product (Kg) PROCESS Furnace oil (Liter) Natural gas (SCM) Coal (KG) Others (KG or Ltr) 1 L Others (KG or Ltr) DIM II—taus 3(i)] Wf ils71471 : 3MTRuT 85 Case Electricity generated by captive power plant and other energy purchased and consumed, electricity partially sold to grid:- • Electricity is generated by coal based captive power plant, partially sold to grid- Y (KWFI) to Grid A (KG) X ( kwh) CPP Natural Gas (SCM) Furnace Oil (Ltr) Others (KG or Ltr) Heat Rate (Kcal/Kwh) Process Product (Kg) Coal (KG) Case -IV: Electricity generated by captive power plant(CPP), other energy purchased and consumed, electricity partially sold to grid from captive power plant:- Electricity is generated by coal based captive power plant, partially sold to grid and captive power plant is in separate boundary- Case -V: Energy purchased and consumed, electricity and heat partially generated through co-generation plant 95 THE GAZETTE OF INDIA : EXTRAORDINARY [PART II—SEc. 3(i)] Elect (KWH) Coal (KG) • PROCESS Z Kcal By-Product (X KG) (c) During the first cycle,designated consumer having less than five years life and less than three years data has been reported, the available year's data shall be considered provided the capacity • Electricity and heat are generated by co-generation Plant- A (KG) 6) lw X ( kwh) Co- Product (Kg) Coal (KG) 31 Gen Y (Kcal) Plant Eff. (%) Natural gas (SCM) Furnace oil (Ltr) Process Others (KG or Ltr) 01 CASE -VI: Energy purchased and consumed, heat energy partially met by waste or by- product of the process- Product (Kg) Natural Gas (SCM) Furnace Oil (Ltr) Others (KG or Ltr) 1.3 Methodology for calculating baseline specific energy consumption.- (a) During the first cycle designated consumer having more than five years life, data for the previous three years, namely, 2007-08, 2008-09, 2009-10 shall be considered provided the capacity utilization is uniform. Normalisation, in a suitable statistical approach, shall be done in case of abnormality in capacity utilisation in any of the aforesaid three year (s). (b) During the first cycle designated consumer having more than five years life and less than three years data has been reported, the same shall be considered provided the capacity utilisation is uniform and if the capacity utilisation is abnormally low in any of the aforesaid three year(s), the same shall not be considered. Elect (KWH) t, [ V171 3(i)] utilisation is uniform. If the capacity utilisation is abnormally low in any of the year(s), the same shall not be considered. (d) During the first cycle, in case of new designated consumer, the data shall be considered for those years where the capacity utilisation is greater than seventy percent. (70%) and if only one year data is reported, the same shall be considered irrespective of the capacity utilisation. (e) In the next cycle, baseline specific energy consumption shall be calculated in accordance with the provisions of rule 14. (e) Few additional sector specific information like process technology, process flow, raw material, product mix etc. shall also be collected. All forms of energy shall be converted into a single form i.e. metric ton of oil equivalent (toe) by the use of standard engineering conversion formula and the following general guiding principle shall be used in this regard:- (i) The reported gross calorific value (GCV) of fuels by the designated consumer, shall be considered for estimating the equivalent thermal energy. (ii) If gross calorific value (GCV)is not reported, then the values mentioned in the Government of India, Ministry of Power, notification number S.0 394(E), dated the 12th March, 2007 shall be considered. Any other information as required shall be taken from standard industrial practice. (iii) The equivalent thermal energy of the electricity supplied to the grid shall be deducted from the total energy input to the designated consumers' boundary. The following expression shall be used:- Equivalent thermal energy (kCal)=Electricity supplied to grid(kWh) x national average heat rate in kCa I/kWh in the baseline year. National average heat rate in year 2009-10 was 2717 kCal/kWh. (iv) Total energy input to the designated consumers' boundary shall be estimated with the following expression:- Energy input (toe) = Fuel consumed quantity (kg) x gross calorific value (kCal/kg) 10 ' (v) Once the total energy input to the designated consumers' boundary is estimated, the specific energy consumption shall he calculated by dividing the product quantity. 1.4 Procedure for normalisation of specific energy consumption.- (a) Variable factors as described in rule 4 may affect the energy consumption and 'Normalisation Factors' shall be considered in those cases. Capacity utilisation is one of the most important parameters to have a normalisation factor. The reported specific energy consumption(SEC) shall be normalised after incorporating the normalisation factor. `grtw : g7 THE GAZETTE OF INDIA : EXTRAORDINARY [PART II—SEC. 3(i)] Normalized specific energy consumption = f (Reported SEC, normalization factors). (b) The specific energy consumption shall be normalised, during baseline and target periods, based on statistical procedures. (c) The normalisation procedure is proposed to he applied if the capacity utilisation or Plant Load Factor (PLF) has a deviation of more than thirty per cent. It shall be applied only if capacity utilisation has deviated due to uncontrollable factors described in rule 4, and duly declared by the designated consumer with authentic proof or self certifications. (d) The normalisation shall be done by performing a statistical analysis of the specific energy consumption and production data by- (i) plotting the production versus energy consumption curves; (ii) performing statistical analysis to represent the relationship between the production and energy consumption; (iii) extrapolating the above relationship to generate capacity utilisation versus energy consumption and capacity utilisation versus specific energy consumption data for a suitable range of capacity utilisation values; (iv) the average capacity utilisation shall be used to identify the corresponding specific energy consumption value; (v) the normalised specific energy consumption shall be the value as computed in the previous step, (e) The "capacity utilisation" referred to in clauses (c) to (d) shall be replaced by "Plant Load Factor" in case of designated consumers in the thermal power plant sector; (f) The above calculation determines the normalised specific energy consumption for the designated consumers. 2. Thermal power plant sector.- 2.1 The designated consumers for the thermal power plant sector shall be grouped based on the fuel used and they are as under:- 2.2 The energy consumption norms and standards for power stations shall be specified in terms of specific percentage of their present deviation of net operating heat rate, based on the average of previous three years, namely, 2007-8,2008-9,2009-10 for the first cycle ,and for cycles thereafter in accordance .svith the provision of rule 14frorn the net design heat rate. The power stations shall be grouped into various bands according to their present deviations, of operating heat rate from design heat rate and for power stations with higher deviations the energy consumption norms and standards shall be established at lower level and shall be grouped taking into account percentage deviation as under:- 1 WTI II --7§11Tg. 3(i) ] 4̀-77 tfq14:i : amit7TZ13l 89 Reduction target for percentage 'deviation in the net statioP heat rate. . Deviation inmpt station heat rate from design .net heat rate . I Ten per cent (10%) Twenty-one per cent. (21%) ten percent More than ten per cent. and upto twenty percent More than twenty per cent. Twenty-four per cent (24%). 2.5 Correction factor considered for effect on heat rate due to coal quality: (a) Average "ash", moisture, and gross calorific value for the previous three years in case of baseline for first cycle and as per rule 14 for consequent cycles and specified year in case of target 4 year, shall be taken into account for the baseline year and correction factor shall be worked out based on the following boiler efficiency formula:- Where: Upto five per cent. More than five per cent and upto Seventeen per cent. (17%) A= Ash percentage in coal M= Moisture percentage in coal H= Hydrogen percentage in coal G.C.V= Gross calorific value in kcal/kg Station heat rate (Kcal/kWh) = Turbine heat rate or Boiler efficiency (b) The permissible error shall be ±0.05% in terms of toe for the purpose of determining entitlement of energy savings certificates. ,3. Cement sector.- 3.1 For establishment of energy consumption norms and standards for designated consumers in the cement sector, the designated consumers shall be grouped based on similar major output or product with the available data to arrive at a logical and acceptable spread of specific energy consumption among the designated consumers which shall be grouped as under- ? Y. Portland Slag Cement Plant (PSC) AL, Normalization Factors I / 7 -Ftrtland Pozzolana temetl! Plant (.PP.C) 90 THE GAZEI 1E OF INDIA : EXTRAORDINARY PART II-SEC. 3(i)] 3.2 Equivalent major grade of cement production.-The various product mixes shall be converted in to equivalent major grade of cement product by the designated consumer by using the following formuiae:- Conversion of Ordinary Portland Cement (OPC) production equivalent to major product OPC produce(' (Lakh ton)X conversion factor of OPC. Equivalent major product = Conversion factor of major product [Lakh ton] (ii) Conversion of Portland Pozzolana (PPC) production equivalent to major product PPC produced (Lakh ton)X Conversion factor of PPC. Equivalent major product = Conversion factor of major product [Lakh ton] (iii) Conversion of Portland Slag Cement (PSC) or any other variety of cement production equivalent to major product Equivalent major product PSC or any othervar cement produced (Lakh ton)X Conversion factor of PSC.' or any other var ietv cement Conversion factor of major product [Lakh ton] (iv) Conversion of total exported clinker to major product Total exp orted el in ker (Lakh ton) Equivalent major product =--- [Lakh ton] Cotmersion ‘ factor of major product Where: Total exported clinker= [Clinker exported to other plants + clinker exported to clinker stock over and above the opening stock,] (v) Conversion of total imported clinker to major product Total imported clin ker (Lakh ton) Equivalent major product = [Lakh tont Conversion factor of major product Where: Total Imported clinker= [Clinker Imported from other plants + clinker Imported from clinker stock, equivalent to the quantity by which the clinker opening stock gets reduced] (vi) Total equivalent major product of cement [ITT II— 1EFT 3(i)] 1-11 Td (1,144 : 347iRTMIT 91 Note: S.no. a(v) is already accounted in major product 3.3 Calculation for Gate to Gate specific energy consumption (SEC) (I) Total thermal energy consumption Total thermal energy consumption is to he calculated as:- Total thermal energy consumption= [Fuel consumed (Lakh ton) X Gross calorific value of respected fuel (kcal/kg) X 100) It can be arrived at by summing up all the different grades of cements equivalent to major product calculated above: Total Equivalent major product of Cement = a(i) +a( ii) +a(iii) + a( iv) [Lakh ton) (Million kcal] (ii) Total electrical energy consumption Total electrical energy consumption is to be calculated as:- Total electrical energy consumption= [{(Total electricity purchased from grid (Lakh kWh) X 860(kcal/kWh)-electricity exported to grid (Lakh kWh) X 2717 (kcal/kWh))/10] [Million kcal] (iii) Notional/ Normalisation energy for imported electricity from grid Notional energy for imported electricity= [Imported electricity (lakh kWh) x (3208- 860) (kcal/kWh)] /10 [Million kcal] Where: - 3208 kcal/kWh is weighted average heat rate of all designated consumers in cement sector. (iv) Notional/ Normalisation energy Required for grinding of exported clinker It is calculated by using.follOwing formula: Notional energy required = {Total exported clinker to major product (Lakh ton) x Electi-ical SEC of cement grinding (kWh/ton of cement) x Weighted average heat rate (kcal/kWh))/10 [Million kcal) Where: -Weighted average heat rate (kcal/kWh) = [(Imported electricity (Lakh kWh) X 3208 (kcal/kWh)} + {diesel generation (lakh kWh) x diesel generator heat rate (kcal/kWh)) + {Captive power plant generation (lakh kWh) x Captive power plant heat rate (kcal/kWh))) /[Imported electricity (Lakh kWh) +diesel generation (Lakh kWh) +Captive power plant generation (Lakh kWh)] (v) Notional/ Normalisation energy required for clinkerisation of imported clinker It is calculated by using following formula: 1178GIr2012-13 Where: - 2717 kcal/kWh is national average heat rate. 92 THE GAZETTE OF INDIA : EXTRAORDINARY [PART II—SEc. 3(i)] Notional energy required [Total clinker imported (Lakh ton) x {Thermal SEC of clinkerization kcal/kg el!nker) x ].000+electrical SEC of clinkerization (kWh/ton or average heat rate (kcal/kWh))/10) !Million kcal) (vi) Gate to Gate (GtG) energy con:urripiun GtG energy consumption =b(i) +b(ii) +b(ii) +b(iv) +b(v) (vii) Gate to Gate (GtG) specific energy consumption [Million kcal] GtG SEC = GIG energy consumption (Million kali) Total equivalent major product of cement (Lakh ton) X 100 [kcal/kg of equivalent cement] 3.4 The permissible error shall be ±1) 05% in terms of toe for the purpose of determining entitlement of energy savings certificates. 4 Aluminum sector.- 4.1 For establishment of energy consumption norms and standards for designated consumers in the Aluminum sector, the designated consumers shall be grouped based on similar major output or product with the available data to arrive at a logical and acceptable spread of specific energy consumption among the designated consumers which shall he grouped as under:- 4.2 The permissible error shall be ±0.05% in terms of toe for the purpose of determining entitlement of energy savings certificates_ 5 Iron and Steel sector.- 5.1 For Establishment of Energy consumption norrns and standards in the Iron and Steel sector, the Designated consumers are grouped based on similar characteristics with the available data to arrive at a logical and acceptable spread of specific Energy consumption among the designated consumers which may be grouped as under:- 5.2 The entire sector can be sub divided in the following 8 sub-sector as detailed below: 5.3 Integrated Steel Plant il*Rd TF3fra : 93 A) Integrated Steel Plant:- The energy indices of the major integrated steel plants captured from tne annual :eports and reported during the baseline audits have been taken for the below calculations. The Gi:te to Gate Specific Energy Consumption may be calculated as follows- Gate to Gate Specific Energy index of the plant Submitted to Ministry of Steel Energy Consumption (SEC) (kca!/tone of crude steel). As regards the total energy consumed in plant for these major integrated steel plants, the following formula can be given- Total Energy Consumed in Plant Iota( Energy Consumption (Mkcal) [Total Thermal Energy (Mkcal) +{Purchased Electricity from Grid (MkWh) *860 kcal/kWh) — {Exported Electricity to grid (MkWh) * Captive Power Plant Heat Rate kcal/kWh}). Where, Total Thermal Energy (Mkcal) =[ Fuel Quantity used (tonne) *Gross Calorific Value of Fuel (kcal/kg))/1000 5.4 Sponge Iron B) Sponge Iron:- for this sub sector only those plants are considered which are standalone sponge Iron plants with no downstream products. The gate to gate SEC may be given as follows: Gate to Gate Specific (Mkcal/ tonne) = Total Energy Consumption (Mkcal) / Production of Sponge Energy Consumption Iron (tonne) 5.5 Sponge Iron with Steel Melting Shop C) Sponge Iron with Steel Melting Shop:- for this sub sector those plants are considered which are sponge Iron plants with SMS (Steel Melting Shop). The gate to gate SEC may be given as follows: In this Group first we convert sponge iron to Steel melting shop and again equivalent Steel Melting Shop to sponge iron as follows- Specific Energy Consumption of Coal for sponge Iron =Tonne of Coal Consumption/Tonne of sponge iron Electrical Specific Energy Consumption for sponge Iron =kWH/Tonne of Sponge Iron. Thermal Specific Energy Consumption for Sponge Iron .{(Tonne/Tonne* Gross Calorific kcal/kWh)} Value of Coal)+(kWH/Tonnt..,)* CPP Heat Rate Electrical Specific Energy Consumption for Steel Melting Shop = kWH/Tonne of Steel Melting Shop. 94 THE GAZE Fib OF INDIA : EXTRAORDINARY [PART II—SEc. 3(i)] Steel Melting Shop Equivalent to Sponge Iron Production =[{(kWH/Tonne)*CPPHeat Rate}*production of Steel melting shop] / (Total Specific Energy Consumption of Sponge Iron) Total Equivalent Sponge Iron Production (Tonne) = Production of Sponge Iron (Tonne) + Steel Melting Shop production equivalent to sponge iron (Tonne) (Gate to Gate SEC) Gate to Gate Specific Energy Consumption (Mkcal/Tonne) = Total Energy consumed (Mkcal)/ Tote Equivalent Sponge Iron Production (Tonne) 5.6 Sponge Iron with Steel Melting shops and other D) Sponge Iron with Steel Melting Shop and others:- for this sub actor those plants are considered which are sponge Iron plants with SMS (Steel Melting Si).* will other products like Ferro Manganese, Silicon Magnanese, Pig Iron etc.. The gate to gate SEC ri.ay De given as follows: In this subsector first we convert equivalent Steel melting shop to Sponge Iron and thereafter equivalent Ferro Alloy is converted to sponge Iron by given formulae. Equivalent Ferro Alloy Manganese to Sponge Iron =[{Electrical SEC of Ferro Manganese(kWH/Tonne)*Heat Rate}*Production of Ferro Alloy Ferro Manganese}/(Total Specific Energy Consumption of Sponge Iron) Equivalent Ferro Alloy Sponge Iron Manganese to Sponge Iron =[{Electrical SEC of Sponge iron Manganese(kWH/Tonne)*Heat Rate}*production of Ferro Alloy Sponge iron Manganese}/(Total Specific Energy Consumption of Sponge Iron) (Pig Iron to Sponge Iron) Equivalent Pig Iron to Sponge Iron =[{Electrical SEC of Pig Iron (kWH/Tonne)*CPP Heat Rate}*production of Ferro Alloy Pig Iron}/(Total Specific Energy Consumption of Sponge Iron) (Total Sponge Iron) Total Equivalent Sponge Iron Production = Total energy Sponge Iron +Ferro Manganese to Sponge Iron + Sponge Iron Manganese to Sponge Iron + Pig Iron to Sponge Iron G to G SEC, Gate to Gate Specific Energy Consumption = Total Energy consumed/ Total Equivalent Sponge Iron Production DIM II—taus 3(i)] 1̀47ff -U,Itto( : 3MTWITT 95 * to Ferro Alloy Sponge iron Manganese = (Electrical SEC of Sponge iron Manganese Production of Sponge iron Manganese)/ Electrical SEC of Sponge iron Manganese) 5.8 Ferro Chrome F) Ferro Chrome:-The Gate to Gate SEC for this subsector is given as follows- t..ott, ,, . ..,,,....,,,, 5.7 Ferro Alloy E) Ferro Alloy:- In this Group we have converted all products as regards equivalent to Ferro alloy (Sponge iron Manganese ) by given formula- Equivalent Ferro Alloy Manganese to Ferro Alloy Sponge iron Manganese = (Electrical SEC of Ferro Manganese * Production of Ferro Manganese)/ Electrical SEC of Sponge iron Manganese) Equivalent Ferro alloy Sponge iron Manganese Equivalent Ferro Chrome to Ferro Alloy Sponge iron Manganese = (Electrical SEC of Ferro Chrome * Production of Ferro Chr=ome)/ Electrical SEC of Sponge iron Manganese) Equivalent Pig Iron to Ferro Alloy Sponge iron Manganese = (Electrical SEC of Pig Iron * Production of Pig Iron)/ Electrical SEC of Sponge iron Manganese) Total Equivalent Ferro Alloy Sponge iron Manganese Production =(Ferro Manganese to Ferro sponge iron Manganese) +(Fe Sponge iron Manganese equivalent to Ferro Sponge iron Manganese) +(Ferro Chrome equivalent to Ferro Sponge iron Manganese) + (Pig Iron to Ferro Sponge iron Manganese) Gate to Gate Specific Energy Consumption =Total Energy consumption (Mkcal))/ Total Equivalent Ferro Alloy Sponge iron Manganese Production Gate to Gate Specific Energy Consumption of Ferro Chrome =Total Energy Consumption (Mkcal)/Total Ferro Chrome Production (Tonne Mini Blast Furnace Mini Blast Furnace:-The G to G SEC for this subsector is given as follows- Gate to Gate Specific Energy Consumption of Mini Blast Furnace =Total Energy Consumption (Mkcal)/Total Production (Tonne). 5.9 G) THE GAZETTE OF INDIA : EXTRAORDINARY [PART II—SEc. 3(0] 5.10 Steel Processing Unit H) Steel Processing Units:- This subsector contributes towards the many such steel processing plants like rerolling, wiredrawing, cold rolling, hot roiling etc. The Gate to Gate SEC for this subsector is given as follows- Gate to Gate Specific Energy Consumption of Steel Processing Unit = Total Energy Consumption (Mkcal)/ Total Production of Steel Processing Unit (Tonne). 5.11 The permissible error shall be ±0.05% in terms of toe for the purpose of determining entitlement of energy savings certificates 6 Chlor-Alkali sector.- 6.1 For establishment of energy consumption norms and standards in the Chlor-Alkali sector, the designated consumers shall be grouped based on similar characteristics with the available data to arrive at a logical and acceptable spread of specific energy consumption among the designated consumers which may be grouped as under:- 6.3 Correction factors developed for variability: (a) Product mix (b) Membrane and Electrode Life 60 kWh/tonne per year is added into specific energy consumption in the baseline year for each plant. For example: Addition of 60 kWh per year: 60 kWh x 860 kCal (In case of Non CPP plants) x 3 years / 10000000 MTOE/tonne Caustic Soda liquefied Chlorine (T) Compressed Hydrogen (Lac NM3) Solid Flakes (T) 1.0 of Equivalent Caustic Soda 0.0615 of Equivalent Caustic Soda 13.889 of Equivalent Caustic Soda 0.219 of Equivalent Caustic Soda ecycled fibre (RCF) Speciality . I I I I 3 ( ) wrra U•Tfl-N : q7 Addition of 60 kWh per year: 60 kWh x 2717kCal (In case of CPP plants) x 3 years / 10000000 MTOE/tonne 6.4 The permissible error shall be ±0.05% in terms of toe for the purpose of determining entitlement of energy savings certificates Pulp and Paper secto:- ... 7.1 For establishment of energy consumption norms and standards in the Pulp and Paper sector, the designated consumers shall be grouped based on similar characteristics with I.he available data to arrive at a logical and acceptable spread of specific energy consumption among the designated consumers and the following guidelines shall be applied to group the designated consumers based on similarity in input raw material and product output on the basis of availability of consif.- ,9nt data:- (I) The input raw materials are Wood, Agro and Recycled Fibre (RCF); (ii) The process outputs are of Chemical Pulping, Chemi-mechanical Pulping and 100% market pulping (iii) The product output of specialty paper, non-specialty paper and newsprint. 7.2 The groups made for Pulp and Paper sector under are: - 7.3 The permissible error shall be ±0.05% in terms of toe for the purpose of determining entitlement of energy savings certificates. 8 Textile sector.- 8.1 For establishment of energy consumption norms and standards in the Textile sector, the designated consumers shall be based on similar characteristics with the available data to arrive at a logical and acceptable spread of specific energy consumption among the designated and the group made are as under:- 98 THE GAZETTE OF INDIA : EXTRAORDINARY [PART 11—SEc. 3(i)] 8.2 The designated consumers whose production is measured in meters of cloth, the average grams per square meter (GSM) as 125 and average width as 44 inches shall be assumed for weight calculations. 8.3 The permissible error shall be ±0.05% in terms of toe for the purpose of determining entitlement of energy savings certificates. 9 Fertilizer sector.- 9.1 In Fertilizer Sector, for manufacturing of Urea fertilizer, out of total energy consumed at designated consumer plant boundary, stoichiometric energy of 2.53 Million Gcal/MT Urea is contained in urea product and goes out as such. Thus, the net energy utilized in urea manufacture is total energy input at designated consumers' boundary reduced by 2.53 Million Gcal/MT Urea. The figure is worked out by considering heat energy of ammonia as 4.46 Million Gcal/MT Ammonia and specific consumption 0.567 MT of Ammonia / MT Urea. 9.2 The permissible error shall be ±0.05% in terms of toe for the purpose of determining entitlement of energy saving certificates. [F. No. 10/6/2008-EC] JYOTI ARORA, Jt. Secy. Printed by the Manager, Government of India Press, Ring Road, Mayapuri, New Delhi-110064 and Published by the Controller of Publications, Delhi-I 10054 Page 1 Page 2 Page 3 Page 4 Page 5 Page 6 Page 7 Page 8 Page 9 Page 10 Page 11 Page 12 Page 13 Page 14 Page 15 Page 16 Page 17 Page 18 Page 19 Page 20 Page 21 Page 22 Page 23 Page 24 Page 25 Page 26 Page 27 Page 28 Page 29 Page 30 Page 31 Page 32 Page 33 Page 34 Page 35 Page 36 Page 37 Page 38 Page 39 Page 40 Page 41 Page 42 Page 43 Page 44 Page 45 Page 46 Page 47 Page 48 Page 49 Page 50 Page 51 Page 52 Page 53 Page 54 Page 55 Page 56 Page 57 Page 58 Page 59 Page 60 Page 61 Page 62 Page 63 Page 64 Page 65 Page 66 Page 67 Page 68 Page 69 Page 70 Page 71 Page 72 Page 73 Page 74 Page 75 Page 76 Page 77 Page 78 Page 79 Page 80 Page 81 Page 82 Page 83 Page 84 Page 85 Page 86 Page 87 Page 88 Page 89 Page 90 Page 91 Page 92 Page 93 Page 94 Page 95 Page 96 Page 97 Page 98

Previous and next

All provisions of Energy Conservation ( Norms and standards for Designated Consumers Form, Time within which, manner of preparation and implementation of scheme, procedure for issue of energy saving certificates and value of per metric ton of oil equivalent of energy consumed ) Rules, 2018

Questions people ask

Is form D of Energy Conservation ( Norms and standards for Designated Consumers Form, Time within which, manner of preparation and implementation of scheme, procedure for issue of energy saving certificates and value of per metric ton of oil equivalent of energy consumed ) Rules, 2018 still in force?

No repeal of Energy Conservation ( Norms and standards for Designated Consumers Form, Time within which, manner of preparation and implementation of scheme, procedure for issue of energy saving certificates and value of per metric ton of oil equivalent of energy consumed ) Rules, 2018 is recorded.