Form D, Energy Conservation ( Norms and standards for Designated Consumers Form, Time within which, manner of preparation and implementation of scheme, procedure for issue of energy saving certificates and value of per metric ton of oil equivalent of energy consumed ) Rules, 2018: Form-D
Energy Conservation ( Norms and standards for Designated Consumers Form, Time within which, manner of preparation and implementation of scheme, procedure for issue of energy saving certificates and value of per metric ton of oil equivalent of energy consumed ) Rules, 2018 - Form D
Text of form D
Form-D
Form-D
c. Balance Energy Savings
Certificates
L__
b Energy Savings Certificates
submitted for compliance
Energy Savings Certificates
Performance Assessment Submitted/Not
Document (Form 'A') Submitted
Compliance
Date of Submission
Note 1: Form D may be filled in accordance with the following guidelines:-
GUIDELINES
1. Name of designated consumer: As per notification from Government of India
(Gol) under clause (g) of section 14
2. Registration number: As per E-filing
3. Sector:
• Aluminium
• Cement
• Chlor Alkali
• Fertilizer
• Iron and Steel
• Pulp and Paper
• Textile
• Thermal Power Plant
1178G/2012-11
If recommended for
purchase
Nos
Issued/Recommended
for purchase
4. Sub Sector:
[PART II—Sec. 3(i)]
I
THE GAZE I I E OF INDIA : EXTRAORDINARY
Si-119-$.ectQi:!..-i„: 6 poweerweit Fuel B6S6a ' '-'''N'I`T' Gas, Oil
Cement
rfbn.inid eeI CVer on 06ed rr* - -It grate* --
Fertilizer Feedstock Based Natural Gas, Naptha
Pulp ancII'ae!L Wood,A2ro, RCF Raw Material Based
Chlor-Alkali
Technology Based
5. List of Documents submitted:
(a) Performance assessment document: Submitted to Bureau of Energy
Efficiency for issue of energy savings certificates.
6. Compliance
Process Based Dr Wet
Tektile " dsed- '13151iiiiihg -Processing , v
COrfIVP44e, Fiber yarn
Membrane cell, Mercury
Smelt ud
(a) Energy savings certificates: Enter +ve value if energy savings certificates
issued to designated consumer or enter -ye value in case recommended for
purchase of energy savings certificates
(b) Energy savings certificates submitted for compliance: If designated consumer
is recommended for purchase of energy savings certificates, then enter value of
energy savings certificates submitted by designated consumer for compliance of
energy consumption norms and standards- saving target of designated
consumer.
(c) Balance energy savings certificates:- Numbers of energy savings certificates
balance. If balance is ZERO than DC is in accordance for compliance of energy
saving target and if balance is -ve than DC will be recommended for penalty.
Undertaking
I/VVe undertake that the information supplied in compliance with energy consumption
and standard documents in this Form 'D' is accurate to the best of my/our knowledge
and if any of the information supplied is found to be incorrect and such information
result into loss to the Central Government or State Government or any of the authority
under them or ar:: other person affected, I/we undertake to indemnify such loss.
I/we agree to extend necessary assistance in case of any enquiry is made in the matter
Signature
Name
Designation
For and behalf of
Name of the Firm/Company!Organisation
SEAL of the Firm/Company/Organisation
4TR-ff ,(1.14 : 3-mmtvi 83 [ iTrri II—cgu.s 3(i)]
Schedule
[See rules 2, 4 and 7]
1. Determination of baseline specific energy consumption.-
1.1 Specific energy consumption (See rule 2(1))
(a) The specific energy consumption (SEC) gives the indication of efficient utilisation of different
sources of energy in a plant operational boundary to produce one unit of product, which is defined
as the ratio of total energy input to plant boundary and the quantity of products produced and
specific energy consumption of an industry shall be calculated based on Gate-to-Gate concept with
the following formula:-
Specific Energy Consumption =
Net energy input into the designated consumers' boundary
Total quantity of output exported from the designated consumers' boundary
and expressed in terms of the metric ton of oil equivalent (toe)/per unit of product;
Note: value to be rounded to three decimal places.
Table 1: Definition of product to calculate specific energy consumption
. Se cto r* '
Cement
Main product Unit
Cement ton
Fertilizer Urea ton
ton Iron and Steel (Integrated) Crude keel
iron and Steel (Sponge Iron) Sponge Iron ton
Aluminium (Refinery)
Aluminium (Smelter)
Alumina
Molten Aluminium
ton
ton
Aluminium (Integrated) Molten Aluminium ton
Pulp and Paper (Pulping) Pulp
Paper
ton
ton Pulp and Paper (Only Paper
Making)
i-
Pulp and Paper (Pulp and Paper) Paper ton
Textile (Spinning)
Textile (Composite)
Yarn
Yarn/Fabric
..._.....
Kg
kg
Textile (Fibre) Fibre kg
Textile (Processing) Fabric kg
Chlor-Alkali Equivalent Caustic Soda ton
Power- Plant Million k4h Electricity
icity (10.NH)
Furnace oil (Liter)
Natural gas (SCM)
Coo! (KG)
X ( kwh)
•
SFC (kwh/ltr)
Process
Others (KG of Ltr)
►r DG
A (Ltr)
Product (Kg)
•
I4
THE GAZETTE OF INDIA : EXTRAORDINARY [PART 3(i)I
1.2 Gate-to-Gate designated consumer boundary (sector-specific)
(a) As the specific energy consumption (SEC) is calculated on a Gate-to-Gate concept, the plant
boundary shall be selected in such a manner that the total energy input and the above product
defined in Table 1, is be fully captured and the entire designated consumers' plant The colony,
residential complex and transportation system, mining operations in case of Iron and Steel,
Aluminum and Cement sectors are not part of designated consumers 'boundary.
(b) Once the 'designated consumers' boundary has been fixed, the same boundary shall be
considered for entire cycle, and any change in the said boundary such as capacity expansion, merger
of two plants, division of operation etc. shall be duly intimated to the Bureau of Energy Efficiency.
(c) The following designated consumers' boundaries will be considered in the first cycle:-
Case -I: All energy purchased and consumed:-
• Electricity is purchased from the grid
Electricity (kWh)
0.1
Furnace Oil (Liter)
Product (Kg)
Natural Gas (SCM) Process •
Coal (KG)
Others (Kg or Ltr)
C se -II: Electricity partially generated by diesel generating(DG) set ,other energy
purchased and consumed:-
• Electricity is purchased from the grid and generated by DG set
G (KWH)
CPP
Y (KWH) to Grid
1
Aux P (a%)
X (KWH)
A
Product (Kg)
PROCESS
Furnace oil (Liter)
Natural gas (SCM)
Coal (KG)
Others (KG or Ltr)
1
L
Others (KG or Ltr)
DIM II—taus 3(i)] Wf ils71471 : 3MTRuT 85
Case Electricity generated by captive power plant and other energy purchased and
consumed, electricity partially sold to grid:-
• Electricity is generated by coal based captive power plant, partially sold to grid-
Y (KWFI) to
Grid
A (KG)
X ( kwh)
CPP
Natural Gas (SCM)
Furnace Oil (Ltr)
Others (KG or Ltr)
Heat Rate (Kcal/Kwh)
Process
Product (Kg)
Coal (KG)
Case -IV: Electricity generated by captive power plant(CPP), other energy purchased and
consumed, electricity partially sold to grid from captive power plant:-
Electricity is generated by coal based captive power plant, partially sold to grid and
captive power plant is in separate boundary-
Case -V: Energy purchased and consumed, electricity and heat partially generated through
co-generation plant
95 THE GAZETTE OF INDIA : EXTRAORDINARY [PART II—SEc. 3(i)]
Elect (KWH)
Coal (KG)
•
PROCESS
Z Kcal By-Product (X KG)
(c) During the first cycle,designated consumer having less than five years life and less than three
years data has been reported, the available year's data shall be considered provided the capacity
• Electricity and heat are generated by co-generation Plant-
A (KG) 6)
lw
X ( kwh)
Co-
Product (Kg)
Coal (KG)
31
Gen
Y (Kcal)
Plant Eff. (%)
Natural gas (SCM)
Furnace oil (Ltr)
Process
Others (KG or Ltr)
01
CASE -VI: Energy purchased and consumed, heat energy partially met by waste or by-
product of the process-
Product (Kg)
Natural Gas (SCM)
Furnace Oil (Ltr)
Others (KG or Ltr)
1.3 Methodology for calculating baseline specific energy consumption.-
(a) During the first cycle designated consumer having more than five years life, data for the
previous three years, namely, 2007-08, 2008-09, 2009-10 shall be considered provided the capacity
utilization is uniform. Normalisation, in a suitable statistical approach, shall be done in case of
abnormality in capacity utilisation in any of the aforesaid three year (s).
(b) During the first cycle designated consumer having more than five years life and less than
three years data has been reported, the same shall be considered provided the capacity utilisation is
uniform and if the capacity utilisation is abnormally low in any of the aforesaid three year(s), the
same shall not be considered.
Elect (KWH)
t,
[ V171 3(i)]
utilisation is uniform. If the capacity utilisation is abnormally low in any of the year(s), the same shall
not be considered.
(d) During the first cycle, in case of new designated consumer, the data shall be considered for
those years where the capacity utilisation is greater than seventy percent. (70%) and if only one year
data is reported, the same shall be considered irrespective of the capacity utilisation.
(e) In the next cycle, baseline specific energy consumption shall be calculated in accordance
with the provisions of rule 14.
(e) Few additional sector specific information like process technology, process flow, raw material,
product mix etc. shall also be collected.
All forms of energy shall be converted into a single form i.e. metric ton of oil equivalent (toe)
by the use of standard engineering conversion formula and the following general guiding principle
shall be used in this regard:-
(i) The reported gross calorific value (GCV) of fuels by the designated consumer, shall be
considered for estimating the equivalent thermal energy.
(ii) If gross calorific value (GCV)is not reported, then the values mentioned in the Government
of India, Ministry of Power, notification number S.0 394(E), dated the 12th March, 2007 shall
be considered. Any other information as required shall be taken from standard industrial
practice.
(iii) The equivalent thermal energy of the electricity supplied to the grid shall be deducted from
the total energy input to the designated consumers' boundary. The following expression
shall be used:-
Equivalent thermal energy (kCal)=Electricity supplied to grid(kWh) x national average heat
rate in kCa I/kWh in the baseline year.
National average heat rate in year 2009-10 was 2717 kCal/kWh.
(iv) Total energy input to the designated consumers' boundary shall be estimated with the
following expression:-
Energy input (toe) = Fuel consumed quantity (kg) x gross calorific value (kCal/kg)
10 '
(v) Once the total energy input to the designated consumers' boundary is estimated, the
specific energy consumption shall he calculated by dividing the product quantity.
1.4 Procedure for normalisation of specific energy consumption.-
(a) Variable factors as described in rule 4 may affect the energy consumption and
'Normalisation Factors' shall be considered in those cases. Capacity utilisation is one of the most
important parameters to have a normalisation factor. The reported specific energy
consumption(SEC) shall be normalised after incorporating the normalisation factor.
`grtw : g7
THE GAZETTE OF INDIA : EXTRAORDINARY [PART II—SEC. 3(i)]
Normalized specific energy consumption = f (Reported SEC, normalization factors).
(b) The specific energy consumption shall be normalised, during baseline and target periods,
based on statistical procedures.
(c) The normalisation procedure is proposed to he applied if the capacity utilisation or Plant
Load Factor (PLF) has a deviation of more than thirty per cent. It shall be applied only if capacity
utilisation has deviated due to uncontrollable factors described in rule 4, and duly declared by the
designated consumer with authentic proof or self certifications.
(d) The normalisation shall be done by performing a statistical analysis of the specific energy
consumption and production data by-
(i) plotting the production versus energy consumption curves;
(ii) performing statistical analysis to represent the relationship between the production and
energy consumption;
(iii) extrapolating the above relationship to generate capacity utilisation versus energy
consumption and capacity utilisation versus specific energy consumption data for a suitable
range of capacity utilisation values;
(iv) the average capacity utilisation shall be used to identify the corresponding specific energy
consumption value;
(v) the normalised specific energy consumption shall be the value as computed in the previous
step,
(e) The "capacity utilisation" referred to in clauses (c) to (d) shall be replaced by "Plant Load
Factor" in case of designated consumers in the thermal power plant sector;
(f) The above calculation determines the normalised specific energy consumption for the
designated consumers.
2. Thermal power plant sector.-
2.1 The designated consumers for the thermal power plant sector shall be grouped based on the
fuel used and they are as under:-
2.2 The energy consumption norms and standards for power stations shall be specified in terms
of specific percentage of their present deviation of net operating heat rate, based on the average of
previous three years, namely, 2007-8,2008-9,2009-10 for the first cycle ,and for cycles thereafter in
accordance .svith the provision of rule 14frorn the net design heat rate. The power stations shall be
grouped into various bands according to their present deviations, of operating heat rate from design
heat rate and for power stations with higher deviations the energy consumption norms and
standards shall be established at lower level and shall be grouped taking into account percentage
deviation as under:-
1
WTI II --7§11Tg. 3(i) ] 4̀-77 tfq14:i : amit7TZ13l 89
Reduction target for
percentage 'deviation in the
net statioP heat rate.
. Deviation inmpt station heat rate
from design .net heat rate
. I Ten per cent (10%)
Twenty-one per cent. (21%)
ten percent
More than ten per cent. and upto
twenty percent
More than twenty per cent. Twenty-four per cent (24%).
2.5 Correction factor considered for effect on heat rate due to coal quality:
(a) Average "ash", moisture, and gross calorific value for the previous three years in case of
baseline for first cycle and as per rule 14 for consequent cycles and specified year in case of target
4
year, shall be taken into account for the baseline year and correction factor shall be worked out
based on the following boiler efficiency formula:-
Where:
Upto five per cent.
More than five per cent and upto Seventeen per cent. (17%)
A= Ash percentage in coal
M= Moisture percentage in coal
H= Hydrogen percentage in coal
G.C.V= Gross calorific value in kcal/kg
Station heat rate (Kcal/kWh) = Turbine heat rate or Boiler efficiency
(b) The permissible error shall be ±0.05% in terms of toe for the purpose of determining
entitlement of energy savings certificates.
,3. Cement sector.-
3.1 For establishment of energy consumption norms and standards for designated consumers in
the cement sector, the designated consumers shall be grouped based on similar major output or
product with the available data to arrive at a logical and acceptable spread of specific energy
consumption among the designated consumers which shall be grouped as under-
?
Y. Portland Slag
Cement Plant
(PSC)
AL,
Normalization Factors
I / 7
-Ftrtland
Pozzolana
temetl! Plant
(.PP.C)
90 THE GAZEI 1E OF INDIA : EXTRAORDINARY PART II-SEC. 3(i)]
3.2 Equivalent major grade of cement production.-The various product mixes shall be converted in
to equivalent major grade of cement product by the designated consumer by using the following
formuiae:-
Conversion of Ordinary Portland Cement (OPC) production equivalent to major
product
OPC produce(' (Lakh ton)X conversion factor of OPC.
Equivalent major product =
Conversion factor of major product
[Lakh ton]
(ii) Conversion of Portland Pozzolana (PPC) production equivalent to major product
PPC produced (Lakh ton)X Conversion factor of PPC.
Equivalent major product =
Conversion factor of major product
[Lakh ton]
(iii) Conversion of Portland Slag Cement (PSC) or any other variety of cement production
equivalent to major product
Equivalent major product
PSC or any othervar cement produced (Lakh ton)X Conversion factor of
PSC.' or any other var ietv cement
Conversion factor of major product
[Lakh ton]
(iv) Conversion of total exported clinker to major product
Total exp orted el in ker (Lakh ton)
Equivalent major product =--- [Lakh ton]
Cotmersion ‘ factor of major product
Where: Total exported clinker= [Clinker exported to other plants + clinker exported
to clinker stock over and above the opening stock,]
(v) Conversion of total imported clinker to major product
Total imported clin ker (Lakh ton)
Equivalent major product = [Lakh tont
Conversion factor of major product
Where: Total Imported clinker= [Clinker Imported from other plants + clinker
Imported from clinker stock, equivalent to the
quantity by which the clinker opening stock gets
reduced]
(vi) Total equivalent major product of cement
[ITT II— 1EFT 3(i)] 1-11 Td (1,144 : 347iRTMIT 91
Note: S.no. a(v) is already accounted in major product
3.3 Calculation for Gate to Gate specific energy consumption (SEC)
(I) Total thermal energy consumption
Total thermal energy consumption is to he calculated as:-
Total thermal energy consumption= [Fuel consumed (Lakh ton) X Gross calorific
value of respected fuel (kcal/kg) X 100)
It can be arrived at by summing up all the different grades of cements equivalent to
major product calculated above:
Total Equivalent major product of Cement = a(i) +a( ii) +a(iii) + a( iv) [Lakh
ton)
(Million kcal]
(ii) Total electrical energy consumption
Total electrical energy consumption is to be calculated as:-
Total electrical energy consumption= [{(Total electricity purchased from grid (Lakh
kWh) X 860(kcal/kWh)-electricity exported
to grid (Lakh kWh) X 2717 (kcal/kWh))/10]
[Million kcal]
(iii) Notional/ Normalisation energy for imported electricity from grid
Notional energy for imported electricity= [Imported electricity (lakh kWh) x (3208-
860) (kcal/kWh)] /10
[Million kcal]
Where: - 3208 kcal/kWh is weighted average heat rate of all designated consumers in
cement sector.
(iv) Notional/ Normalisation energy Required for grinding of exported clinker
It is calculated by using.follOwing formula:
Notional energy required = {Total exported clinker to major product (Lakh ton) x
Electi-ical SEC of cement grinding (kWh/ton of cement)
x Weighted average heat rate (kcal/kWh))/10
[Million kcal)
Where: -Weighted average heat rate (kcal/kWh) = [(Imported electricity (Lakh kWh) X
3208 (kcal/kWh)} + {diesel generation (lakh kWh) x diesel generator heat rate
(kcal/kWh)) +
{Captive power plant generation (lakh kWh) x Captive power plant heat rate
(kcal/kWh))) /[Imported electricity (Lakh kWh) +diesel generation (Lakh kWh)
+Captive power plant generation (Lakh kWh)]
(v) Notional/ Normalisation energy required for clinkerisation of imported clinker
It is calculated by using following formula:
1178GIr2012-13
Where: - 2717 kcal/kWh is national average heat rate.
92 THE GAZETTE OF INDIA : EXTRAORDINARY [PART II—SEc. 3(i)]
Notional energy required [Total clinker imported (Lakh ton) x {Thermal SEC of
clinkerization kcal/kg el!nker) x ].000+electrical SEC of
clinkerization (kWh/ton or
average heat rate (kcal/kWh))/10)
!Million kcal)
(vi) Gate to Gate (GtG) energy con:urripiun
GtG energy consumption =b(i) +b(ii) +b(ii) +b(iv) +b(v)
(vii) Gate to Gate (GtG) specific energy consumption
[Million kcal]
GtG SEC =
GIG energy consumption (Million kali)
Total equivalent major product of cement (Lakh ton) X 100
[kcal/kg of equivalent cement]
3.4 The permissible error shall be ±1) 05% in terms of toe for the purpose of determining
entitlement of energy savings certificates.
4 Aluminum sector.-
4.1 For establishment of energy consumption norms and standards for designated consumers in the
Aluminum sector, the designated consumers shall be grouped based on similar major output or
product with the available data to arrive at a logical and acceptable spread of specific energy
consumption among the designated consumers which shall he grouped as under:-
4.2 The permissible error shall be ±0.05% in terms of toe for the purpose of determining
entitlement of energy savings certificates_
5 Iron and Steel sector.-
5.1 For Establishment of Energy consumption norrns and standards in the Iron and Steel sector,
the Designated consumers are grouped based on similar characteristics with the available data to
arrive at a logical and acceptable spread of specific Energy consumption among the designated
consumers which may be grouped as under:-
5.2 The entire sector can be sub divided in the following 8 sub-sector as detailed below:
5.3 Integrated Steel Plant
il*Rd TF3fra : 93
A) Integrated Steel Plant:- The energy indices of the major integrated steel plants captured
from tne annual :eports and reported during the baseline audits have been taken for the below
calculations. The Gi:te to Gate Specific Energy Consumption may be calculated as follows-
Gate to Gate Specific
Energy index of the plant Submitted to Ministry of Steel
Energy Consumption (SEC) (kca!/tone of crude steel).
As regards the total energy consumed in plant for these major integrated steel plants, the
following formula can be given-
Total Energy Consumed in Plant
Iota( Energy Consumption (Mkcal) [Total Thermal Energy (Mkcal) +{Purchased Electricity
from Grid (MkWh) *860 kcal/kWh) — {Exported Electricity to grid (MkWh) * Captive Power Plant
Heat Rate kcal/kWh}).
Where, Total Thermal Energy (Mkcal) =[ Fuel Quantity used (tonne) *Gross Calorific Value of
Fuel (kcal/kg))/1000
5.4 Sponge Iron
B) Sponge Iron:- for this sub sector only those plants are considered which are standalone
sponge Iron plants with no downstream products. The gate to gate SEC may be given as follows:
Gate to Gate Specific (Mkcal/ tonne) = Total Energy Consumption (Mkcal) / Production of Sponge
Energy Consumption Iron (tonne)
5.5 Sponge Iron with Steel Melting Shop
C) Sponge Iron with Steel Melting Shop:- for this sub sector those plants are considered which
are sponge Iron plants with SMS (Steel Melting Shop). The gate to gate SEC may be given as follows:
In this Group first we convert sponge iron to Steel melting shop and again equivalent Steel Melting
Shop to sponge iron as follows-
Specific Energy Consumption of Coal for sponge Iron =Tonne of Coal Consumption/Tonne of
sponge iron Electrical Specific Energy Consumption for sponge Iron
=kWH/Tonne of Sponge Iron.
Thermal Specific Energy Consumption
for Sponge Iron .{(Tonne/Tonne* Gross Calorific
kcal/kWh)}
Value of Coal)+(kWH/Tonnt..,)* CPP Heat Rate
Electrical Specific Energy Consumption for Steel Melting Shop = kWH/Tonne of Steel Melting
Shop.
94 THE GAZE Fib OF INDIA : EXTRAORDINARY [PART II—SEc. 3(i)]
Steel Melting Shop Equivalent to
Sponge Iron Production =[{(kWH/Tonne)*CPPHeat Rate}*production of Steel melting shop] / (Total
Specific Energy Consumption of Sponge Iron)
Total Equivalent Sponge Iron
Production (Tonne) = Production of Sponge Iron (Tonne) + Steel Melting Shop production
equivalent to sponge iron (Tonne)
(Gate to Gate SEC) Gate to Gate Specific Energy
Consumption (Mkcal/Tonne) = Total Energy consumed (Mkcal)/ Tote Equivalent Sponge Iron
Production (Tonne)
5.6 Sponge Iron with Steel Melting shops and other
D) Sponge Iron with Steel Melting Shop and others:- for this sub actor those plants are
considered which are sponge Iron plants with SMS (Steel Melting Si).* will other products like
Ferro Manganese, Silicon Magnanese, Pig Iron etc.. The gate to gate SEC ri.ay De given as follows:
In this subsector first we convert equivalent Steel melting shop to Sponge Iron and thereafter
equivalent Ferro Alloy is converted to sponge Iron by given formulae.
Equivalent Ferro Alloy Manganese
to Sponge Iron =[{Electrical SEC of Ferro Manganese(kWH/Tonne)*Heat Rate}*Production of Ferro
Alloy Ferro Manganese}/(Total Specific Energy Consumption of Sponge Iron)
Equivalent Ferro Alloy
Sponge Iron Manganese to Sponge Iron =[{Electrical SEC of Sponge iron
Manganese(kWH/Tonne)*Heat Rate}*production of Ferro Alloy Sponge iron Manganese}/(Total
Specific Energy Consumption of Sponge Iron)
(Pig Iron to Sponge Iron) Equivalent Pig Iron to
Sponge Iron =[{Electrical SEC of Pig Iron (kWH/Tonne)*CPP Heat Rate}*production of Ferro Alloy
Pig Iron}/(Total Specific Energy Consumption of Sponge Iron)
(Total Sponge Iron) Total Equivalent Sponge
Iron Production = Total energy Sponge Iron +Ferro Manganese to Sponge Iron + Sponge Iron
Manganese to Sponge Iron + Pig Iron to Sponge Iron
G to G SEC, Gate to Gate Specific Energy
Consumption = Total Energy consumed/ Total Equivalent Sponge Iron Production
DIM II—taus 3(i)] 1̀47ff -U,Itto( : 3MTWITT 95
* to Ferro Alloy Sponge iron Manganese = (Electrical SEC of Sponge iron Manganese
Production of Sponge iron Manganese)/ Electrical SEC of Sponge iron Manganese)
5.8 Ferro Chrome
F) Ferro Chrome:-The Gate to Gate SEC for this subsector is given as follows-
t..ott,
,, . ..,,,....,,,,
5.7 Ferro Alloy
E) Ferro Alloy:-
In this Group we have converted all products as regards equivalent to Ferro alloy (Sponge iron
Manganese ) by given formula-
Equivalent Ferro Alloy Manganese to Ferro Alloy Sponge iron
Manganese = (Electrical SEC of Ferro Manganese * Production of Ferro Manganese)/ Electrical
SEC of Sponge iron Manganese)
Equivalent Ferro alloy Sponge iron Manganese
Equivalent Ferro Chrome to Ferro Alloy Sponge iron
Manganese = (Electrical SEC of Ferro Chrome * Production of Ferro Chr=ome)/ Electrical SEC of
Sponge iron Manganese)
Equivalent Pig Iron to Ferro Alloy Sponge iron
Manganese = (Electrical SEC of Pig Iron * Production of Pig Iron)/ Electrical SEC of Sponge iron
Manganese)
Total Equivalent Ferro Alloy
Sponge iron Manganese Production =(Ferro Manganese to Ferro sponge iron Manganese) +(Fe
Sponge iron Manganese equivalent to Ferro Sponge iron Manganese) +(Ferro Chrome equivalent to
Ferro Sponge iron Manganese) + (Pig Iron to Ferro Sponge iron Manganese)
Gate to Gate Specific Energy Consumption =Total Energy consumption (Mkcal))/ Total
Equivalent Ferro Alloy Sponge iron Manganese Production
Gate to Gate Specific Energy Consumption
of Ferro Chrome =Total Energy Consumption (Mkcal)/Total Ferro Chrome Production (Tonne
Mini Blast Furnace
Mini Blast Furnace:-The G to G SEC for this subsector is given as follows-
Gate to Gate Specific Energy Consumption
of Mini Blast Furnace =Total Energy Consumption (Mkcal)/Total Production (Tonne).
5.9
G)
THE GAZETTE OF INDIA : EXTRAORDINARY [PART II—SEc. 3(0]
5.10 Steel Processing Unit
H) Steel Processing Units:- This subsector contributes towards the many such steel processing
plants like rerolling, wiredrawing, cold rolling, hot roiling etc.
The Gate to Gate SEC for this subsector is given as follows-
Gate to Gate Specific Energy Consumption
of Steel Processing Unit = Total Energy Consumption (Mkcal)/ Total Production of Steel Processing
Unit (Tonne).
5.11 The permissible error shall be ±0.05% in terms of toe for the purpose of determining
entitlement of energy savings certificates
6 Chlor-Alkali sector.-
6.1 For establishment of energy consumption norms and standards in the Chlor-Alkali sector,
the designated consumers shall be grouped based on similar characteristics with the available data
to arrive at a logical and acceptable spread of specific energy consumption among the designated
consumers which may be grouped as under:-
6.3 Correction factors developed for variability:
(a) Product mix
(b) Membrane and Electrode Life
60 kWh/tonne per year is added into specific energy consumption in the baseline year for
each plant. For example:
Addition of 60 kWh per year: 60 kWh x 860 kCal (In case of Non CPP plants) x 3 years /
10000000 MTOE/tonne
Caustic Soda
liquefied Chlorine (T)
Compressed Hydrogen (Lac NM3)
Solid Flakes (T)
1.0 of Equivalent Caustic Soda
0.0615 of Equivalent Caustic Soda
13.889 of Equivalent Caustic Soda
0.219 of Equivalent Caustic Soda
ecycled fibre (RCF)
Speciality
. I I I I 3 ( ) wrra U•Tfl-N : q7
Addition of 60 kWh per year: 60 kWh x 2717kCal (In case of CPP plants) x 3 years / 10000000
MTOE/tonne
6.4 The permissible error shall be ±0.05% in terms of toe for the purpose of determining
entitlement of energy savings certificates
Pulp and Paper secto:- ...
7.1 For establishment of energy consumption norms and standards in the Pulp and Paper sector,
the designated consumers shall be grouped based on similar characteristics with I.he available data
to arrive at a logical and acceptable spread of specific energy consumption among the designated
consumers and the following guidelines shall be applied to group the designated consumers based
on similarity in input raw material and product output on the basis of availability of consif.- ,9nt data:-
(I) The input raw materials are Wood, Agro and Recycled Fibre (RCF);
(ii) The process outputs are of Chemical Pulping, Chemi-mechanical Pulping and 100%
market pulping
(iii) The product output of specialty paper, non-specialty paper and newsprint.
7.2 The groups made for Pulp and Paper sector under are: -
7.3 The permissible error shall be ±0.05% in terms of toe for the purpose of determining
entitlement of energy savings certificates.
8 Textile sector.-
8.1 For establishment of energy consumption norms and standards in the Textile sector, the
designated consumers shall be based on similar characteristics with the available data to arrive at a
logical and acceptable spread of specific energy consumption among the designated and the group
made are as under:-
98 THE GAZETTE OF INDIA : EXTRAORDINARY [PART 11—SEc. 3(i)]
8.2 The designated consumers whose production is measured in meters of cloth, the average
grams per square meter (GSM) as 125 and average width as 44 inches shall be assumed for weight
calculations.
8.3 The permissible error shall be ±0.05% in terms of toe for the purpose of determining
entitlement of energy savings certificates.
9 Fertilizer sector.-
9.1 In Fertilizer Sector, for manufacturing of Urea fertilizer, out of total energy consumed at
designated consumer plant boundary, stoichiometric energy of 2.53 Million Gcal/MT Urea is
contained in urea product and goes out as such. Thus, the net energy utilized in urea manufacture is
total energy input at designated consumers' boundary reduced by 2.53 Million Gcal/MT Urea. The
figure is worked out by considering heat energy of ammonia as 4.46 Million Gcal/MT Ammonia and
specific consumption 0.567 MT of Ammonia / MT Urea.
9.2 The permissible error shall be ±0.05% in terms of toe for the purpose of determining
entitlement of energy saving certificates.
[F. No. 10/6/2008-EC]
JYOTI ARORA, Jt. Secy.
Printed by the Manager, Government of India Press, Ring Road, Mayapuri, New Delhi-110064
and Published by the Controller of Publications, Delhi-I 10054
Page 1
Page 2
Page 3
Page 4
Page 5
Page 6
Page 7
Page 8
Page 9
Page 10
Page 11
Page 12
Page 13
Page 14
Page 15
Page 16
Page 17
Page 18
Page 19
Page 20
Page 21
Page 22
Page 23
Page 24
Page 25
Page 26
Page 27
Page 28
Page 29
Page 30
Page 31
Page 32
Page 33
Page 34
Page 35
Page 36
Page 37
Page 38
Page 39
Page 40
Page 41
Page 42
Page 43
Page 44
Page 45
Page 46
Page 47
Page 48
Page 49
Page 50
Page 51
Page 52
Page 53
Page 54
Page 55
Page 56
Page 57
Page 58
Page 59
Page 60
Page 61
Page 62
Page 63
Page 64
Page 65
Page 66
Page 67
Page 68
Page 69
Page 70
Page 71
Page 72
Page 73
Page 74
Page 75
Page 76
Page 77
Page 78
Page 79
Page 80
Page 81
Page 82
Page 83
Page 84
Page 85
Page 86
Page 87
Page 88
Page 89
Page 90
Page 91
Page 92
Page 93
Page 94
Page 95
Page 96
Page 97
Page 98
Previous and next
Questions people ask
Is form D of Energy Conservation ( Norms and standards for Designated Consumers Form, Time within which, manner of preparation and implementation of scheme, procedure for issue of energy saving certificates and value of per metric ton of oil equivalent of energy consumed ) Rules, 2018 still in force?
No repeal of Energy Conservation ( Norms and standards for Designated Consumers Form, Time within which, manner of preparation and implementation of scheme, procedure for issue of energy saving certificates and value of per metric ton of oil equivalent of energy consumed ) Rules, 2018 is recorded.