Form AT, Bureau of Energy Efficiency (Manner and Intervals of Time for Conduct of Energy Audit )Regulations, 2010: FORMAT
Bureau of Energy Efficiency (Manner and Intervals of Time for Conduct of Energy Audit )Regulations, 2010 - Form AT
Text of form AT
FORMAT
FORMAT
[See regulation 6 (2)1
Guidefir es for
re aratLL21.___ Energy ,\Lidit.fEtep9_rj
Each energy audit report shall include --
(1) Title page
- Report title
- Client name
- Location of the plant/establishment
- Date of report
- Name of the accredited energy auditors
(2) Table of contents
(3) Acknowledgement
(4) Executive summary
- Company's profile
- Goals and objectives of the ene; gy
management programme
- Major challenge and goals for the
upcoming year.
- Major activities to meet challenges and
goal
- Summary and classification of energy
-
Conservation measures — should be in Form 2.
1.0
Introduction about the plantiestabiishment
1.1 General plant/establishment details
and descriptions
1.2 Energy audit team
1.3 Component of production cost (raw materials, E:neigy,
chemicals,
manpower, overhead, others)
1.4 Major energy use areas
1I71III I i.TT7T (1,444 : 3RITYRu1 31
2.0 Production process description
2.1 Brief description of manufacturing process
2.2 Process flow diagram and major unit operations
2.3 Major raw material Inputs, quantity and costs
3.0 Energy and utility system description
3.1 List of utilities
3.2 Brief description of each utility
3.2.1 Electricity
3.2.2 Steam
3.2.3 Water
3.2.4 Compressed air
3.2.5 Chilled water
3.2.6 Cooling water
3.2.7 Others
4.0 Detailed process flow diagram and energy and material balance
4.1 Flow chart showing flow rate, temperature, pressures of all input-
output streams
4.2 Water balance for entire industry
4.3 Energy balance of the designated consumer in the tabular form
5.0 Performance evaluation of major utilities and process equipments/
systems
5.1 List of equipments and process where performance testing was done
5.2 Results of performance testing
6.0 Energy efficiency in utility and process system
6.1 Specific energy consumption
6.2 Boiler efficiency assessment
TI IF, GAZETTE OF INDIA : EXTRAORDINARY I PAH, III Si (
32
6.3 Thermic fluid heater performance assessment
6.4 Furnace efficiency analysis
6.5 Cooling water system performance assessment
6.6 Diesel Generator set performance assessment
6.7 Refrigerator system-performance
6.8 Compressed air system performance
6.g Electric motor load analysis
6.10 Lighting system
6.11 Others.
7.0 Evaluation of energy management system
7.1 Energy management policy
7.2 Energy management monitoring system
7.3 Bench marking
7.4 Development and establishment of procedures include energy efficiency
possibilities
7.5 Training to staff responsible for operational and associated processes
7.6 General audit review
7.7 Conform to Act. rules and regulations framed there under
7.8 Strength and weaknesses of the designated consumer.
8.0 Energy conservation measures and recommendations
8.1 The report shall provide existing energy profile of the designated consumer with
percentage share of major equipment / processes, utilities etc., so that it
becomes a basic documents for future monitoring.
8.2 Details of energy saving measures recommended in Form 2
8.3 Cost benefit analysis of each recommended energy saving measures
as per standard practice.
8.4. The investment proposals shall be backed with technical and economic viability
and prioritization of energy conservation measures based on financial analysis
of various options taking into account the capacity of the designated consumer
to make investment in such measures.
['1177 I II ---"Uu 4 ]
14117 (1,141 . 3TRTNITtr1
8.5. The energy auditor may also consider the substitution of existing energy use by
any other form of techno-commercially viable form of energy.
8.6. Details of energy saving measures implemented, investment made and saving
in energy achieved together with progress made in the implementation of the
remaining energy saving measures in Form 3.
9.0 Certification
This part shall indicate certification by accredited energy auditor stating that-
(i) the data collection has been carried out diligently and truthfully;
(ii) all data monitoring devices are in good working condition and have
been calibrated or certified by approved agencies authorised and no
tempering of such devices has occurred;
(iii) all reasonable professional skill, care and diligence had been taken in
preparing the energy audit report and the contents thereof are a true
representation of the facts;
(iv) adequate training provided to personnel involved in daily operations
after implementation of recommendations; and
(v) the energy audit has been carried out in accordance with the Bureau of
Energy Efficiency (Manner and Intervals of Time .for the Conduct of
Energy Audit) Regulations, 2010.
Signature
Name of the accredited energy auditor
Accreditation details
Seal
AJAY MATH UR, Director-General
[ADVI III/4/185/1 0-Exty]
Printed by the Manager. Government of India Press. Rim! Road. Mayapuri, New Delhi-110064
and Published by the Controller of Publications. Delhi-I 10054
Page 1
Page 2
Page 3
Page 4
Page 5
Page 6
Page 7
Page 8
Page 9
Page 10
Page 11
Page 12
Page 13
Page 14
Page 15
Page 16
Page 17
Page 18
Page 19
Page 20
Page 21
Page 22
Page 23
Page 24
Page 25
Page 26
Page 27
Page 28
Page 29
Page 30
Page 31
Page 32
Page 33
Previous and next
Questions people ask
Is form AT of Bureau of Energy Efficiency (Manner and Intervals of Time for Conduct of Energy Audit )Regulations, 2010 still in force?
No repeal of Bureau of Energy Efficiency (Manner and Intervals of Time for Conduct of Energy Audit )Regulations, 2010 is recorded.