Regulation 5, Bureau of Energy Efficiency ( Particulars and Manner of their Display on labels of Tubular Fluorescent lamps ) Regulations, 2009: Manner of display of label
Bureau of Energy Efficiency ( Particulars and Manner of their Display on labels of Tubular Fluorescent lamps ) Regulations, 2009 - Regulation 5
Text of regulation 5
Manner of display of label
5. Manner of display of label.- (1)On every tubular fluorescent lamp, the label shall be
stamped as follows, namely:-
(i) the label with colour programme after photographic reduction to 16 millimetre
height shall be printed on the sleeve;
(ii) all the manufacturers and importers would mark the colour temperature on
the sleeve;
(iii) the star marking as per the rating is required to be stamped on the tubular
fluorescent lamp where the size of the stamp for the star marking shall be
14.5 millimetre height by 8.5 millimetre width and the same shall be stamped
in a separate column.
All dimensions
in millimetres
1■:t
*74
POWER SAVINGS GUIDE
Under test conditions when
tested in accordance to IS t
2418. Actual efficiency will
vary as per site conditions. SINSIIIVE I
X 49 4
Schedule
[See regulation 3(2)]
Details of particulars to be displayed on label of Tubular Fluorescent Lamp
(a) Label design, size, colour scheme and content of the label shall include -
(i) the following dimensional design of label ,namely:-
8ESlE—'rtinFUi PLAN
STAR RATING . , * i
Lumens per Wall at 0100 hrs of use <61 >=61 & <67 >=67 E. <86 >=96 & <92 >=92
Lumens per Waft at 2000 hrs of use <52 >=52 & <57 >=57 & <77 >=17 & <8-1 ,-.83
Lumens per Watt at 3500 hrs of use <49 >af49 & <54 >=54 & <73 >=73 & :78 >=78
11-
36 p. .4--.019 4
97 I 0.
13 4_1-11F13 'I-- 13 —10'13 41--
.158 5mM
BEE STAR RATING PLAN
STAR RATING * ** *- ,:-
Lumens per Watt at 0100 hrs of use <61 >=61 & <67 >=67 & <86 >=86 & <92 >=92
Lumens per Watt at 2000 hrs of use <52 >=52 & <57 ),-.57 & <77 >=77 & <83 ›.83
Lumens per Watt at 3500 hrs of use <49 >=49 & <54 >=54 & <73 >=73 & <78 ).78
58.5 22.2 mm . 29.2 mm 29.2 mm 29.2 mm 29.2 mm • mm •---- ---1
* * *
MORE STARS
MORE LIGHT
POWER SAVINGS GUIDE
(ii) the following colour scheme for the label, namely
NAVY BLUE - Hue — 240° Saturation 100% Brightness 40% (Red — 0, Green — 0, Blue — 102)
GREEN - Hue —150° Saturation 100% Brightness 65% (Red — 0, Green — 165, Blue — 83)
Note: Bottom of BEE logo and star filler in GREEN colour only. All fonts and fop of BEE logo in NAVY BLUE
(iii) the following colour scheme for Bureau's logo, namely:-
BLUE -
Hue(1-1)-239° Saturation(S):64% Brightness(B):59%
Luminance or lightness(L) :28, chromatic components -a:24 b:54
Red(R):54 Green(G):55 Blue(B):151
Cyan(C):97% Magenta(M):95% Yellow(Y):6°/0 Black(K):1%
Web colour code - #363797
GREEN -
Hue(H)-150° Saturation(S):10% Brightness(B):67%
Luminance or lightness(L) :61, chromatic components -a:-53 b:32
Red(R):0 Green(G):170 Blue(B):87
Cyan(C):81% Magenta(M):10% Yellow(Y):90% Black(K):1%
Web colour code - #00M56;
(iv) the following complete specimen of a printed label for room tubular fluorescent lamp on the casing when not on display,
namely:-
BEE STAR RATING PLAN
STAR RATING 2 , ., 2 n 7 - - , • 2 ; + r L
Lumens per Walt at 0100 hrs of use <61 >=61 & <67 >=67 & <86 >=86& <92 >=92
i
Lumens per Watt at 2000 hrs of use <52 >=52 & <57 >=57 & <77 >=77 & <83 >r-.83
Lumens per Watt at 3500 hrs of use <43 >=49 & <54 >=54 & <73 >=73 & <78 >=78
Under test conditions wheniE ERGYISLIFE
tested in accordance to IS ; e
2418. Actual efficiency will ?..c
vary as per site conditions. '4 MUM IT
THE GAZETTE OF INDIA : EXTRAORDINARY [PART 111—SEc. 4]
(b) The following complete specimen of star marking label for tubular fluorescent
lamp stamped on the sleeve, namely:-
AJAY MATHUR, Director General
[ADVT-III/4/185/09/Exty]
10
Previous and next
Questions people ask
Is regulation 5 of Bureau of Energy Efficiency ( Particulars and Manner of their Display on labels of Tubular Fluorescent lamps ) Regulations, 2009 still in force?
No repeal of Bureau of Energy Efficiency ( Particulars and Manner of their Display on labels of Tubular Fluorescent lamps ) Regulations, 2009 is recorded.