Rule 15, G.S.R. 186(E) These rules may be called the Environment Protection) Amendment Rules, 2008: Hg
G.S.R. 186(E) These rules may be called the Environment Protection) Amendment Rules, 2008 - Rule 15
Text of rule 15
Hg
15.Hg . - 0.01 4}
16.In
50
17.Ni
10
18.Cv
10
19.V
0.2
20. Benzene - : Q.1
fiL Benzo (a] - Pyrene
02
Notes.-
{i)-Concentration limits shall be complied with at the outlet, discharging
effluent (excluding discharge from sea water cooling systems) to
receiving environment (surface _water
[ =T 3()]
T 1 T ¢ SRR
15
1 3 - | 4
Bodies, marine systems or public sewers). In case of application of
jreated effiuent directly- for imgation/horficulture: purposes {within of
outside the premises of refinery}. make-up water for cooling systems,
fire fighting, etc., the concentration limits shall alsc be complied with
af the outlet before taking the effivent for such application. However,
cany use in fhe process such as use of sour water in desalter Is
excluded for the purpose of compliance.
fi) In case of circulating seawater cooling, the blow-down from
cooling systems shall be monitored for pH and oil & grease (also
hexavalent & total -chromium, if chromate treatment s given to
cooling water) and shall conform to.the concentration fimits for these
porameters. In case of reuse of ireated effluent as cooling water
make-up, all the parameters {as applicable for treated effluent}-shall
be monitored and conform to the prescribed standards.
(i) in’ case of once through cooling with seawater, the ‘oil & grease
content in the effluent from cooling water shall not exceed 1.0 mg/l.
B. Emissions
(Fumace,
Limiting concentration in mg/Nm?, unless stated
refineries | Boiler
Sulphur Dioxide Gos” 50 50
(5O3) Liquid 1700 850
FuelType | Existing | New Refinery/Furnace/ | g
Boiler and T Oxides of . Gas 350 . 250
captive
Power
Piant)
Nitrogen (NOx) Liquid 450 350
Farticulate Matter | Gas ~ 10 5
(PM) .
Liquid 100 50
Corbon Monoxide | Gas_ 150 » 100.
(cO) Liguid 200 150
Nickel and Liquid 5 i 5
Vanadium [Ni+V)
5
Hydrogen Liquid / 150 150
Sulphide- (HzS) in gas
fuel gas
Sulphurcontent in Liquid/ 1.0 0.5
liquid fuel, weight | gas
%
.
Notes.-
(iv) In case of mixed fue! (gas and liquid) use, the limit shafl be
computed based on heat supplied by gas and liquid fuels.
(i) Al the fumaces/boilers with heat input of 10 million kilo
calories/hour or mofe shall have continuous systems for
monitoring of $O2 and NOx. Manual. monitoring for afl the
emission parameters in such fumnaces or boilers shall be
canied out once in two months.
(iii) Al the emission parameters in furnaces/boilers having heat
Jorysifed Y
16 THE GAZETTE OF INDIA : EXTRAORDINARY [Pasr I—Sec. 3()]
2 3 4
input less than 10 million kilo calories/nour will be monitored
once in three months.
{iv) In case of continuous monitoring, one hourly Qaverage
concentration values shall be complied with 98% of the time
in a Month. Any concentration value obtained through
manual monitoring, if exceeds the limiting concentration
value, shall be considered as non-compliance,
(v) Dota on Nickel and Vanadium content in the liquid fuel (in
ppm] shall be reported. Nickel and Vanadium in the liquid
fuel shall be monitored af least once in six months, if liquid
fuel source & quality are not changed. In case of changes,
measurement is necessary after every change.
{FCC Regen- Limiting concentration in mg/Nm3, unless erators)
stated
Existing refineries New Refinery
hydro Other than | /FCC
processed Hydro Commissioned
FCC feed processed
FCC feed
Sulphur Dioxide 500 1700 500 (for hydro-
(SO2)
processed
| feed)
850 (for other
feed}
Oxides of 400 450 350
Nitrogen (NOJ .
Particulate 100 100 50
Matter (PM)
Carbon 400 400 300 Monoxide {CO) I
Nickel and - 2 5 2
Vanadium
(Ni+V)
Opacity, % 30 - 30 30
Notes:
{i) In case part feed is hydro-processed.. the emission values
shall be calculated proportional to the feed rates of untreated
and treated feeds.
(i) FCC regenerators shall have continuous systems for
monitoring of SOz and NO,. One hourly average concentration values shall be complied with 98% of the fime in a month, in case of continuous monitoring. Manual monitoring for all the
emission parameters shall be carried out once in two months.
[ I—'vs 3() ] MIRA 1 T : STENRY 17
3 i 4 1 2
.| (i) Any - concentration - value obtained through manual
monitoring, if exceeds the fimiting concen"cmon value, shall be
considered as non-compliance.
v/ ~Data on Sulghur (weight in. %), Nickel (PPM) and
Vanadium -{PPM} content in the feed to FCC shall be reported
reguiarly .
(V) Limit of Carbon ‘Meonoxide = emissions shal'lbe complied
with except during annual shut down of CO boiler for
statutory maintenance. N
Plont Existing SRU Newsw«lmy
capaclly Commissioned
day)
Sulphur Above 20 98.7 99.5
{Sulphur recovery, % : .
Recovery HzS, 15 . 10
Units (SRUJ} - | mg/Nm2 .
Suiphur . | 5-20 96 - 98
recovery, % . -
Sulphur 1-5 94 96
recovery, % .
Oxides of All capacity 35 - 250
Nitrogen
(NG,
mg/Nm3
Carbon All capacity 150 100
Monoxide
(CO). i
mg/Nm?3
Notes:
(i) Sulphur recovery units having capacity above 20 tonnes
per day shall have tonfinuous systems for monitoring of SO2.
Manual monitoring for ali the emission parameters shall be
carried out oncein a momh‘
{ii) Data on Sulphur Dioxide’ emissions (mg/Nm?) shall be
reported regularly.
{iii} Sulphur recovery efficiency shall be calculated on
menthly basis, using quantity of sulphur in the feed to SRU and
quantity of sulphur recovered
18 THE GAZETTE OF INDIA': EXTRAORDINARY [Pary I—S&c. 3(i)]
Cc- F'uglfivc Emission
Storage of Volatile Liquids : General Petroleum Products
(1) Storage tanks with capacity between 4 fo 75m? and total vapour Pressure {TVP)
of more than 10 kpa should have Fixed Roof Tank (FRT) with pressure valve vent.
(2} Storage tanks with the capacity between 75 to 500 m? and total vapour Pressure
(TVP) of 10 to 76 kpa should have Internal Floating Roof Tank (IFRT) or External
Floating Roof Tank (EFRT) or Fixed Roof Tank with vapour control or vapour
balancing system.
(3) Storage tanks wnth the capacity of more than 500 m? and fotal vapour Pressure
(TVP) of 10 to 76 kpa should have Internal Fioating Roof Tank or External F|oqnng
Roof Tank or Fixed Roof Tank with vapour control system.
(4) The tanks with the capacity of more than 75 m? and total vapour Pressure(TVP) of
more than 76 kpa should have Fixed Roof Tank with vapour controt system.
{5) Requirement for seals in Fioafirig Roof Tanks:
{i) (o) IFRT and EFRT shall be provided with double seals with minimum
vapour recovery of 96%.
(b) Primary seal shall be liquid or shoe mounted for EFRT and vapour
mounted for IFRT. Maximum seal gap width will be 4 cm and
maximum gap area will be 200 cm?/m of tank diameter.
(c) Secondary seal shall be rim mounted. Maximum seal gap width will
be 1.3 cm and maximum gap area wif be 20 cmZ/m of tank
diometer.
{d) Material of seal and construction shall ensure high performance and
durability.
(i) Fixed Roof Tanks shall have vapour control efficiency of 95% and
vapour balancing efficsepcy of 90%.
{iiiy Inspection and maintenance of storage tanks shall be caried out
under strict control. For the inspection, API RP 575 may be adopted.
_In-service inspection with regard seal gap should be caried out
once in every six months and repair to be implemented in short time.
In future, possibility of on-stream repair of both seals shall be
examined.
Storage of Voldtile liquids : Benzene Storage *
(1) FRT with vapour to incineration with 99.9% of removal efficiency for volatile
crganic compounds (VOC) shall be provided.
(2) IFRT/EFRT with double seals, emission-reducing roof fitting and fitted with fixed
roof with vapour removal efficiency of at least 99% shall be provided.
[am—avE 3] IR T O SR
(y
2
3)
(4}
(5)
Solvents for Lube-Base Of producHon (Furfural, NMP, MEK, Toluene and MIBK)
IFRT with double seals and inert gas blcnk'efir\g with vapour removal efficiency of
at least 97% shall be provided.
{Emission control for Road Tank truck/ Rail tank wagon loading .
Loading of | Gasoline and Naphtha: ’
Volatile {i) vOC reduction. % i) 99.5
“Products
(i) Emission. gm/m?3 i) S
Benzene:
{iy vOC reduction, % i 99.99
| i) Emission, mg/m? (i) - 20
Toluene/Xylene:
i) VOC reduction, % W 9998
(ii) Epmission, mg/m? (i) 150
M Note:
W It shail be applicable for Gasoline, Naphtha, Benzene.
< Toluene and Xylene loading.
{i)) Road tank Truck shalt have Bottom loading and Rail tank
wagon shall have Top submerged loading.
(it} Annual leak testing for vapour cqlleclion shall be done.
standards for Equipment Leaks
Approach: Approach for controlling fugitive emissions from equipment leaks shall
have proper selection, instaliation and maintenance of non-eaking or leak-fight
equipment. Following initial testing after commissioning, the monitoring for leak
detection is to be caried out as a permanent on-going Leak Detection and Repair
(LDAR) programme. finally detected leaks are to be repaired within olkowable time
frame. .
Compoenents to be Covered: Components that shall be covered under LDAR
- programme include {i) ‘Block valves; (i) Control . valves; fii} Pump secls;” {iv]
Compressor _sea\s; (v) Pressure relief ‘valves: [vi) Flonges - Heat Exchangers: (vil)
Flanges - Piping; (viil) Connectars - Piping; (ix} Open ended lines; and (x) Sampling
connections. Equipment ond line 'sizes more than 1.875 cm or % inch are fo be
covered. :
Applicability: LDAR programme would be applicable to components {given at 2
above) for following sproducts/compounds:
(i) hydsocarbon gases; (i) Light liguid with
vapour pressure @ 200C > 1.0 kPa:; and {ii) Heavy liquid with vapour pressure @ 20°C
between 0.3 to 1.0kPa.
While LDAR will not be applicabie for heavy liquids with vapour pressure < 0.3 kPa, it
will be desirable to check for liquid dripping as indication ofteak.
Definition of leak: Aleakis defined s the detection of VOC concentration more than
the. values (in ppm) specified pelow at the emission source using a hydrocarbon
analyzer according to measurement profocol (US EPA - 453/R-95-017, 1995 Protocol
for equipment leak emission estimdtes may be referred to:
THE GAZETTE OF INDIA : EXTRAORDINARY [ParT II—Skc. 3(i)]
Component General Hydrocarbon (ppm) | Benzene (ppm|
Til 31¢ Dec. | w.ef. January | TH 31+ Dec. | welf.
2008 01, 2009 - 2008 ) January
‘ 01, 2009
Pump/Compressor | 10000 5000 3000 2000 Valves/Flanges 10000 3000 2000 1000 Other components | 10000 3000 2000 1000
(6) In addition, any component observed to be leaking by sight, sound or smell, regardless of concentrafion {liquid dripping, visible vapor leak) or presence of bubbiles using soap solution should be considered as leak.
(7). Monitoring Requirements and Repair Schedule: Following frequency of monitoring of leaks and schedule for repair of leaks shiall be followed: .
Component Frequency of monitoring ~ | Repair schedule
Quarterly (semiannual Repair will be started within 5
after two consecutive working days and shall be
periods with < 2% leaks completed within 15 working
and annual - after 5 | days after detection of leak for
perieds with < 2% leaks) general hydrocarbons. In case Pump seals Quartery of benzene, the leak shall be Compressor sedls Quarterly attended immediately for
Pressure relief Quarterly repair.
devices :
Pressure relief Within 24 hours
devices {after
. venting} )
Heat Exchangers Quarterly
Process drains Annually
Components that Annually
are difficult to
monitor
Pump seals with Immediately Immediately visible liquid ’
dripping
Any component Immediately Immediately-
with visible leaks
Any component Within five days -
after
repair/replacement
(8) The percentage leaking components should not be more than 2% for any group of components, monitored excluding pumps/compressors. In case of pumps/compressors, it should be less than 10% of the total number of pumps/compressors or three pumps and compressors, whichever is greater.
(9) Emission Inventory: Refinery shall prepare an inventory of equipment components in the plant. After ‘the instrumental measurement of leaks, emission from the components will be calculated using stratified emission factors {USEPA) or any other superior factors. The total fugitive emission will be established.
{10} Monitoring: Following types of monitoring methods may be Judiciously employed for delection of leaks: (i) Instrumental method of measurement of leaks; (i) Audio, visual and olfactory (AVO) leak detection; and {iii) Soap bubble method.
[wnn—wfi 331 NRE 1 TR 2 SR : 21
(11) Data on time of measurement and concentrafion value for leak detection: time of
repair of leak; and time- of measurement & concentration value after repair of leak
should be documented for all the compenents.
(12) Pressure relief and blow down systems should discharge to a vapour collgbtim and
recovery system or fo flare. . .
(13) Open-ended lines should be closed by’a blind flange or plugged;
(14)" Totally closed-loop should be used in alt routing samples.
(15) Low emission packing shod!d be used forvalves.
(18) High integrity sefi"ng materidls should be used for flanges.
D. Emission Standards for VOC from Wastewaiter Collection and Treatment
(1) Al contaminated and odorous.wastewater streams shall be handied in closed systems
from. the source to the primary freatment stages (oilwater “separator and
equalizafion fanks).
(2) - The collection system shall be covered with tha seals {traps) on sewers and drains
and gas tight covers on junction boxes.
{3) Oil-water separators and equaiization tarks shall’ be provided with floating/fixed
covers. The off-gas generated shall be freated to remove af least 90% of VOC and
eliminate odour. The system design shall ensure safety {prevention-of formation of
explosive mixture, possible detonation” and -reduce the impact) by dilution with
airfinert gas, installing LEL detector including control devices, seal drums, detonation
anestors, etc. The system shall be designed.and operated for safe maintenance of
the collection and primary treatment systems.
(4) » Wastewater from aromatics. plants (benzene and xylene plants) shall be treated to
remove benzene & total aromatics to a level of 10, 20 ppm respectively béfore
discharge to effiuent freatment system without dilution.”’
(b) Serial number 35, velc'ing‘lo *oil refineries, (sulphur oxide) and entries relating
theteto shall'be omitted;
{i) inSchedule VI, inPart C, -
{a) serial number ? relating to “Oil Refinery Industry’ and entries relafing theteto,
the following serlal number and entries shall be substituted, namely :-
“1. Peroleum Oll Refinary :,
Paramedier Standard
' 1 - 2
Quantum limit in Kg/ 1,000 fonne of crude processed R
1. Oil & Grease 20 . -
2. BOD3goy. 2% 60
3. CoD c 50
4. Suspended Solids 80
5. Phenols 0.14
6. Sulphides 0.2
7. CN 0.08
8. Ammonia as N 6.0 i
9. TKN 16
10. P 12
11. Cr [Hexavalent) 004
12. Cr (Total) 08
13.Pb 0.04
THE GAZETTE OF INDIA : EXTRAORDINARY [Part I—Skc. 3()]
Parameter : Standard .-
1 2
Quantum limit in Kg/ 1,000 tonne of crude processed
14. Hg 0.004 )
15.2n . . 20
16. Ni N 04
17.Cu 04
18.V 0.8
19. Benzene 0.04
20. Benzo (a) - Pyrene 0.08
Notes :
(i) Quantum limits sholl be applicable for discharge of total effiuent {process effluent,
cooling water blow down including sea cooling water blow down, washings, etc.) to
receiving environment (gxcluding direct apglication on land for imgation/horticulture
purposes within the premises of refinery).
(i) In order to measure the quantity of effiuent (separately for discharge to receiving
environment, application for imgation/horticulture purposes within the premises of
refinery & blow-down of cooling systems), appropriate fiow measuring devices (e.g.
V-notch, flow meters) shall be provided with.
(i} Quantum of pollutants shall be caiculated on the basis of daily average of
coneentration values (one 24-houry composite sample or average of three grab
samples, as the case may be), average flow of effluent during the day and crude
throughput capacity of the refinery. =+ .
(iv) Limit for quantity of effiuent discharged fexcluding blow-down from seawater
cooling) shall be 400 m3/1000 tonne of crude processed. However, for refineries
" | located in high rain fall area, limit of quantity of effluent only during rainy days shall be
700 m3/1000 tonne of crude processed.”.
[F. No. Q-15017/15/2007-CPW]
R. K. VAISH, Jt. Secy.
Note : - The principal rules were published in the Gazette of India vide number S.0. 844
(E) 19" November, 1986 and subsequently amended vide S.0. 433 (E) dated 18" April,
1987, S.0. 64 (E) dated 18" January, 1988, 5.0. 3 (E) dated 3" January, 1989, S.0. 190
(E) dated 15" March, 1989, G.S.R. 913 (E) dated the 24" October, 1989, S.0. 12 (E)
dated the 8" January, 1990, G.S.R. 742 (E) dated the 30" August, 1990, S.0. 23 (E) dated the 16" January, 1991, G.S.R. 93 (E) dated the 21% February, 1991 G.S.R. 95 (€)
dated the 12" February, 1992, G.S.R. 329 (E) dated the 13® March, 1992, G.5.R. 475 (E)
dated the 5" May, 1992 G.S.R. 797 (E) dated the 1% October, 1992, G.S.R. 386 (E) dated the 28" April, 1993, g.s.r. 422 (e) dated the 19™ May, 1993, G.S.R. 801 (E) dated the 3t* December, 1993, G.S.R. 176 (E) dated the 3" April, 1996, G.S.R. 631 (E) dated the 31 October, 1997, G.S.R. 504 (E) dated the 20" August, 1998, G.S.R. 7 (E) dated the 2" January, 1999, G.S.R. 682 (E) dated the 5" October, 1999, G.S.R. 742 (E) dated the 25" September, 2000, G.S.R. 72 (E) dated the 6™ February, 2001, G.S.R. 54 (E) dated the 22™ January, 2002, G.S.R. 371 (E) dated the 17 May, 2002, G.S.R. 489 (E) dated the 9™ July, 2002, S.0. 1088 (E) dated the 11™ October, 2002 and G.S.R. 849 (E) dated the 30% December, 2002, G.S.R. 520 (E) dated 1% July, 2003, G.S.R. 92 (E) dated 25" January,
2004, G.S.R. 448 (E) dated 12" July, 2004, Corrigenda G.S.R. 520 (E) dated 12* August, 2004, GS.R. 272 (E) dated 5™ May, 2005, G.S.R. 315 (E) dated 16" May, 2005, G.S.R. 546 (E) dated 30" August, 2005, G.S.R. 46 (E) dated 3" February, 2006, G.S.R. 464 (E)
dated 7 August, 2006 , G.S.R. 566 (E) dated 29 August, 2007 and G.S.R, 704 (E) dated
12" November, 2007.
Printed by the Manager, Govt. of India Press, Ring Road, Mayapuri, New Delhi-110064
and Published by the Controller of Publications, Delhi-110054.
Previous and next
Questions people ask
Is rule 15 of G.S.R. 186(E) These rules may be called the Environment Protection) Amendment Rules, 2008 still in force?
No repeal of G.S.R. 186(E) These rules may be called the Environment Protection) Amendment Rules, 2008 is recorded.