Rule 94, The Explosives Rules, 2008: Precautions to be observed while firing
The Explosives Rules, 2008 - Rule 94
Text of rule 94
Precautions to be observed while firing
94. Precautions to be observed while firing.—(1)
The end of the safety fuse should be freshly cut before
being lighted.
(2) The exploders shall be regularly tested and
maintained in a fit condition for use in firing. An exploder
shall not be used for firing a circuit above its rated capacity.
(3) The electric circuit shall be tested for continuity
before firing. All persons other than the shot firer and his
assistants, if any, shall be withdrawn from the site before
testing the continuity.
(4) For the purpose of joining, the ends of all wires
and cables should have the insulation removed for a
maximum length of 5 centimeters and should then be made
clean and bright for a minimum length of 2.5 centimeters
and the ends to be joined should be twisted together so as
to have a positive metal contact.