Rule 83, The Explosives Rules, 2008: Explosives permitted for possession and sale from shop
The Explosives Rules, 2008 - Rule 83
Text of rule 83
Explosives permitted for possession and sale from shop
83. Explosives permitted for possession and sale
from shop.—(1) No explosives, other than fireworks, gun
powder, small arm nitro compound and safety fuse,
permitted in licence shall be stored in a shop for possession
and sale.
(2) Construction of shop.—The shop shall be
constructed of a brick, stone or concrete and the shop
shall be closed and secured so as to prevent unauthorised
person from having access thereto.
(3) The premises shall have storage area not less
than nine square meters and not more than twenty five
square meters.
(4) The shop shall —
(a) be located on the ground floor of a building
completely separated from other parts of the
building by substantial walls having
independent entrance and emergency exit from
open air and having doors opening outwards,
if applicable;
(b) not be situated in the sub-level or basement or
mezzanine floor;
(c) not be situated under the upper floor used for
the purpose of dwelling;
(d) not be situated under or nearby any staircase
or lift;
(e) be accessible for fire fighting; and
(f) have no electrical apparatus or battery or oil
lamp or similar equipments capable of
producing spark or ignition and all electrical
wiring in the shop be fixed and effectively
sealed or conduited or mechanically protected;
the main switch or circuit breaker be provided
at the immediate accessible position outside
the premises.