Rule 29, The Explosives Rules, 2008: Interior of buildings to be suitably finished
The Explosives Rules, 2008 - Rule 29
Text of rule 29
Interior of buildings to be suitably finished
29. Interior of buildings to be suitably finished.—
A building in which explosives or any ingredient thereof
which either by itself is possessed of explosives' properties,
or which when mixed with any other ingredient or article
also present in such building is capable of forming an
explosive mixture or an explosive compound, kept or resent,
or in the course of manufacture is liable to be, shall be a
danger building; and the interior of every such building,
and the benches, shelves and fittings in such building
(other than the machinery) shall be so constructed or so
lined or covered as to prevent the exposure of any iron or
steel and the formation and detachment of any grit so as to
come into contact with the explosive or ingredient thereof
in such building and such interior benches, shelves and
fittings shall, as far as reasonably practicable, be kept free
from grit and otherwise clean.
Previous and next
Questions people ask
Is rule 29 of the Explosives Rules, 2008 still in force?
No repeal of the Explosives Rules, 2008 is recorded.