Rule 42, Atomic Energy (Factories) Rules, 1996: FIRE PROTECTION,PREVENTION & FIGHTING

Atomic Energy (Factories) Rules, 1996 - Rule 42

Text of rule 42

FIRE PROTECTION,PREVENTION & FIGHTING

42. FIRE PROTECTION,PREVENTION & FIGHTING.- (1) Processes & equipment, plant, etc. involving serious explosion and serious fire hazards.- (a) All processes, storages, equipments, plants etc. involving serious explosion and flash fire hazard shall be located in segregated buildings where the equipment shall be so arranged that only a minimum number of employees are exposed to such hazards at any one time. (b) All industrial processes involving serious fire hazard should be located in building or work places separated from one another by walls of fire-resistant construction. (c) Equipment and plant involving serious fire or flash fire hazard shall, wherever possible, be so constructed and installed that in case of fire, they can be easily isolated. (d) Ventilation ducts, pneumatic conveyors and similar equipment involving a serious fire risk should be provided with flame-arresting or automatic fire extinguishing appliances or fire resisting dampers electrically interlocked with heat sensitive / smoke detectors and the air-conditioning plant system. (e) In all workplaces having serious fire or flash fire hazards, passages between machines, installations or piles of material should be at least 90 cm wide. For storage piles, the clearance between the ceiling and the top of piles shall not be less than 2 m. (2) Access for fire fighting. - (a) Buildings and plants shall be so laid out and roads, passageways etc. so maintained as Atomic Energy Factory Rules, 1996 51 Rule 42 to permit unobstructed access for fire fighting. The main exit ways shall have width not less than 4.5m. and vertical clearance not less than 5m. (b) Doors and/or window openings shall be located in suitable position on all external walls of the building to provide easy access to the entire area within the building for fire fighting. (3) Protection against lightning.- Protection from lightning shall be provided for- (a) buildings in which explosive or highly flammable substances are manufactured, used, handled or stored; (b) storage tanks containing oils, paints, or other flammable liquids; (c) grain elevators; (d) buildings, tall chimneys or stacks where flammable gases, fumes, dust or lint are likely to be present; and (e) sub-station buildings and outdoor transformers / switchyards. (4) Explosives.-All explosives shall be handled, transported, stored and used in accordance with the provisions in the Indian Explosives Act, 1884 (4 of 1884). (5) Precautions against ignition.-Wherever there is danger of fire or explosion from accumulation of flammable or explosive substances in air- (a) all electrical apparatus shall either be excluded from the area of risk or they shall be of such construction and so installed and maintained as to prevent the danger of their being a source of ignition; (b) effective measures shall be adopted for prevention of accumulation of static charges to a dangerous extent; (c) workers shall wear shoes without iron or steel nails or any other exposed ferrous materials which is likely to cause sparks by friction; (d) smoking, lighting or carrying of matches, lighters or smoking materials shall be prohibited; (e) transmission belts with iron fasteners shall not be used; and Atomic Energy Factory Rules, 1996 52 Rule 42 (f) all other precautions, as are reasonably practicable, shall be taken to prevent initiation of ignition from all other possible sources such as open flames, frictional sparks, overheated surfaces of machinery or plant, chemical or physical- chemical reaction and radiant heat. (6) Spontaneous ignition.- Where materials are likely to induce spontaneous ignition, care shall be taken to avoid formation of air pocket and to ensure adequate ventilation. The materials susceptible to spontaneous ignition shall be stored in dry condition and shall be in heaps of adequate capacity and separated by adequate passage. The materials susceptible to ignition and stored in the open shall be at a distance not less than 10 m. away from process/storage buildings. (7) Cylinders containing compressed gas.- Cylinders containing compressed gas may only be stored in open if they are protected against excessive variation of temperature, direct rays of sun, or continuous dampness. Such cylinders shall never be stored near highly flammable substances, furnaces or hot processes. The room where such cylinders are stored shall have adequate ventilation. (8) Storage of flammable liquids.- (a) The quantity of flammable liquids in any work room shall be the minimum required for the process or processes carried on in such room. Flammable liquids shall be stored in suitable containers with close fitting covers: Provided that not more than 30 litres of flammable liquids having a flash point of 23 degree C or less shall be kept or stored in any work room without licence as specified in Sec.8 of the Petroleum Act of 1934. (b) Flammable liquids shall be stored in closed containers as specified in the Petroleum rules and in limited quantities in well ventilated rooms of fire resisting construction which are isolated from the remaining of the building by fire walls and self closing fire doors. (c) Large quantities of such liquids shall be stored in containers constructed of iron or steel as per relevant I.S. Codes. These containers shall be stored in isolated and adequately ventilated building of fire resisting construction or in storage tanks, preferably underground and at a distance from any building as required in the Petroleum Rules, 1976. (d) Effective steps shall be taken to prevent leakage of such liquids into basements, sumps or drains and to confine any escaping liquid within safe limits. Atomic Energy Factory Rules, 1996 53 Rule 42 (9) Accumulation of flammable dust, gas, fume or vapour in air or flammable waste material on the floors.- (a) Effective steps shall be taken for removal or prevention of the accumulation in the air of flammable dust, gas, fume or vapour to an extent which is likely to be dangerous. (b) No waste material of a flammable nature shall be permitted to accumulate on the floors and shall be removed at least once in a day or shift, and more often, when possible. Such materials shall be placed in suitable metal containers with covers wherever possible. (10) Fire exits.- (a) In this rule- (i) "horizontal exit" means an arrangement which allows alternative egress from a floor area to another floor at or near the same level in an adjoining building or an adjoining part of the same building with adequate separation; and (ii) "travel distance" means the distance an occupant has to travel to reach an exit. (b) An exit may be a doorway, corridor, passageway to an external stairway or to a verandah or to an internal stairway segregated from the rest of the building by fire resisting walls which shall provide continuous and protected means of egress to exterior of a building or to an exterior open space. An exit may also include a horizontal exit leading to an adjoining building at the same level. (c) Lifts, escalators and revolving doors shall not be considered as exits for the purpose of this sub-rule. (d) In every room of a factory exits sufficient to permit safe escape of the occupants in case of fire or other emergency shall be provided which shall be free of any obstruction. (e) The exits shall be clearly visible and suitably illuminated with suitable arrangement, whatever artificial lighting is to be adopted for this purpose, to maintain the required illumination in case of failure of the normal source of electric supply. (f) The exits shall be marked in a language understood by the majority of the workers. (g) Iron rung ladders or spiral staircases shall not be used as exit staircases. (h) Fire resisting doors or roller shutters shall be provided at appropriate places along the escape routes to prevent Atomic Energy Factory Rules, 1996 54 Rule 42 spread of fire and smoke, particularly at the entrance of lifts or stairs where funnel or flue effect may be created inducing an upward spread of fire. (i) All exits shall provide continuous means of egress to the exterior of a building or to an exterior open space leading to a street. (j) Exits shall be so located that the travel distance on the floor shall not exceed 30m. (k) In case of those factories where high hazard materials are stored or used, the travel distance to the exit shall not exceed 22.5 m and there shall be at least two ways of escape from every room, however small, except toilet rooms, so located that the points of access there to are out of or suitably shielded from areas of high hazard. (l) Wherever more than one exit is required for any room space or floor, exits shall be placed as remote from each other as possible and shall be arranged to provide direct access in separate directions from any point in the area served. (m) The unit of exit width used to measure capacity of any exit shall be 50 cm. A clear width of 25 cm. shall be counted as an additional half unit. Clear width of less than 25 cm. shall not be counted for exit width. (n) Occupants per unit width shall be 50 for stairs and 75 for doors. (o) For determining the exits required, the occupant load shall be reckoned on the basis of actual number of occupants within any floor area or 10 sq.m per person, whichever is more. (p) There shall not be less than two exits serving every floor area above and below the ground floor, and at least one of them shall be an internal enclosed stairway. (q) For every building or structure used for storage only, and every section thereof considered separately, shall have access to at least one exit so arranged and located as to provide a suitable means of escape for any person employed therein, and in any such room wherein more than 10 persons may be normally present, at least two separate means of exit shall be available, as remote from each other as practicable. (r) Every storage area shall have access to at least one means of exit which can be readily opened. Atomic Energy Factory Rules, 1996 55 Rule 42 (s) Every exit doorway shall open into an enclosed stairway, a horizontal exit on a corridor or passageway providing continuous and protected means of egress. (t) No exit doorway shall be less than 100 cm in width. Doorways shall be not less than 200 cm. in height. (u) Exit doorways shall open outwards, that is, away from the room but shall not obstruct the travel along any exit. No door when opened, shall reduce the required width of stairway or landing to less than 90 cm. Over head or sliding doors shall not be installed for this purpose. (v) An exit door shall not open immediately upon a flight of stairs. A landing of at least 1.5m X 1.5m in size shall be provided in the stairway at each doorway. The level of landing shall be the same as that of the floor which it serves. (w) The exit doorways shall be openable from the side which they serve without the use of a key. (x) Exit corridors and passageways shall be of a width not less than the aggregate required width of exit doorways leading from there in the direction of travel to the exterior. (y) Where stairways discharge through corridors and passageways, the height of the corridors and passageways shall not be less than 2.4 m. (z) In the case of enclosed staircases, all windows therein falling within 3m of any other opening in the building shall normally be protected by wired glass in steel framework. In the case of open sided staircases, windows and door openings of the building falling within 3m of the staircase shall normally be protected by wired glass in steel framework and single fireproof door respectively. (aa) A staircase shall not be arranged round a lift shaft unless the latter is totally enclosed by a material having a fire-resistance rating not lower than that of the type of construction of the former. (bb) Hollow combustible construction shall not be permitted. (cc) The minimum width of an internal staircase shall be 100 cm. (dd) The minimum width of treads without nosing shall be 25 cm. for an internal staircase. The treads shall be constructed and maintained in a manner to prevent slipping. Atomic Energy Factory Rules, 1996 56 Rule 42 (ee) The maximum height of a riser shall be 19 cm. and the number of risers shall be limited to 12 per flight. (ff) Hand rails shall be provided with a minimum height of 100 cm. and shall be firmly supported. (gg) The use of spiral stair case shall be limited to low occupant load and to a building of height of 9 m , unless they are connected to platforms such as balconies and terraces to allow escapees to pause. A spiral staircase shall be not less than 300 cm. in diameter and have adequate head room. (hh) The width of a horizontal exit shall be same as for the exit doorways. (ii) The horizontal exit shall be equipped with at least one fire door of self closing type. (jj) The floor area on the opposite or refuge side of a horizontal exit shall be sufficient to accommodate occupants of the floor areas served, allowing not less than 0.3 m2The refuge area shall be provided with exits adequate to meet the requirements of this sub-rule. At lest one of the exits shall lead directly to the exterior or street. (kk) Where there is difference in level between connected areas for horizontal exit, ramps not more than 1 in 8 slope shall be provided. For this purpose steps shall not be used. (ll) Doors in horizontal exits shall be openable at all times. (mm) Ramps with a slope of not more than 1 in 12 may be substituted for the requirements of staircase. For all slopes exceeding 1 in 12 and wherever the use is such as to involve danger of slipping, the ramp shall be surfaced with non-slipping material. (nn) In any building not provided with automatic fire alarm a manual fire alarm system shall be provided if the total capacity of the building is over 500 persons, or if more than 25 persons are employed above or below the ground floor, except that no manual fire alarm shall be required in one-storey buildings where the entire area is undivided and all parts thereof are clearly visible to all occupants. (11) First-aid fire fighting arrangements.- (a) In every factory there shall be provided and maintained adequate and suitable fire fighting equipment for fighting fires in the early stages, those being referred to as first-aid fire Atomic Energy Factory Rules, 1996 57 Rule 42 fighting equipment in this rule. b) The types of first-aid fire fighting equipment to be provided shall be determined by considering the different types of fire risks which are classified as follows:- (i) "Class A fire" - Fire due to combustible materials such as wood, textiles, paper, rubbish and the like. (1) "Light hazard" - Occupancies like offices, assembly halls , canteens, rest- rooms, ambulance rooms and the like; (2) "Ordinary hazard" - Occupancies like saw mills, carpentry shop, small timber yards, book binding shops, engineering workshop and the like; (3) "Extra hazard"-Occupancies like large timber yards, godowns storing fibrous materials, flour mills, cotton mills, jute mills, large wood working factories and the like; (ii) "Class B fire" - Fire in flammable liquids like oil, petroleum products, solvents, grease, paint, etc. (iii) "Class C fire" - Fire arising out of gaseous substances. (iv) "Class D fire" - Fire from reactive chemicals, active metals and the like. (v) “Class E fire" - Fire involving electrical equipment and delicate machinery and the like. (c) The number and types of first-aid fire fighting equipment to be provided shall be as given in Schedule I to this rule. For "ordinary hazard or extra hazard occupancies equipments as given in sub-rule (12) shall be provided in addition to that given in Schedule I. (d) The first-aid fire fighting equipment shall conform to the relevant Indian Standards. (e) As far as possible the first-aid fire fighting equipment shall all be similar in shape and appearance and shall have the same method of operation. (f) All first-aid fire fighting equipment shall be placed in a conspicuous position and shall be readily and easily accessible for immediate use. Generally, these equipment shall be placed as near as possible to the exits or staircase landing or normal routes of escape. Atomic Energy Factory Rules, 1996 58 Rule 42 (g) All water buckets and bucket pump type extinguishers shall be filled with clean water. All sand buckets shall be filled with clean, dry and fine sand. (h) All other extinguishers shall be charged appropriately in accordance with the instructions of the manufacturer. (i) Each first-aid fire fighting equipment shall be allotted a serial number by which it shall be referred to in the records. The following details shall be painted with white paint on the body of each equipment. (1) Serial number: (2) Date of last refilling; and (3) Date of last inspection. (j) First-aid fire fighting equipment shall be placed on platforms or in cabinets or hanged from brackets in such a way that their bottom is 750 mm above the floor level. Fire buckets shall be placed on hooks attached to a suitable stand or wall in such a way that their bottom is 750 mm above the floor level. Such equipment if placed outside the building, shall be under shades or covers. (k) All extinguishers shall be thoroughly cleaned and recharged immediately after discharge. Sufficient refill material shall be kept readily available for this purpose at all times. (l) All first-aid fire fighting equipment shall be subjected to routine maintenance, inspection, and testing to be carried out by properly trained persons. Periodicity of the routine maintenance, inspection and test shall conform to the relevant Indian Standards. (12) Other fire fighting arrangements.- (a) In every factory, adequate provision of water supply for fire fighting shall be made and where the amount of water required in litres per minute, as calculated from the formula A + B + C + D divided by 20 is 550 or more, power driven trailer pumps of adequate capacity to meet the requirement of water as calculated above shall be provided and maintained. In the above formula - A = the total area in sq.m of all floors including galleries in all buildings of the factory; B = the total area in sq.m of all floors and galleries including open spaces in which combustible Atomic Energy Factory Rules, 1996 59 Rule 42 material are handled or stored; C = the total area in sq.m of all floors over 15 m above ground level; and D = the total area in sq.m of all floors of all buildings other than those of fire resisting construction: Provided that in areas where the fire risk involved does not require use of water, such areas under B,C or D may, for the purpose of calculation, be halved: Provided further that where the areas under B, C or D are protected by permanent automatic fire fighting installations approved by any fire association or fire insurance company such areas may, for the purpose of calculation, be halved: Provided also that where the factory is situated at not more than 3 km from an established city or town fire service, the pumping capacity based on the amount of water arrived at by the formula above may be reduced by 25%; but no account shall be taken of this reduction in calculating water supply required under clause(a). (b) Each trailer pump shall be provided with equipment as per Schedule II to this rule. Such equipment shall conform to the relevant Indian Standards. (c) Trailer pumps shall be housed in a separate shed or sheds which shall be sited close to a principal source of water supply in the vicinity of the main risks of the factory. (d) In factories where the area is such as cannot be reached by man-hauling of trailer pumps within reasonable time vehicles with towing attachment shall be provided at the scale of one for every four trailer pumps with a minimum of one such vehicle kept available at all times. (e) Water supply shall be provided to give flow of water as required under clause (a) for at least 100 minutes. At least 50% of this water supply or 450,000 litres whichever is less, shall be in the form of static tanks of adequate capacities (not less than, 45,000 litres each) distributed round the factory with due regard to the potential fire risks in the factory, where piped supply is provided the size of the main shall not be less than 15 cm. diameter and it shall be capable of supplying a minimum of 4500 litres per minute at a pressure of not less than 700 kPa (7kg/sq.cm.) (f) All trailer pumps including the equipment provided with them and the vehicles for towing them shall be maintained in good condition and subjected to periodical inspection and testing as Atomic Energy Factory Rules, 1996 60 Rule 42 required. (13) Personnel in charge of equipment and for fire fighting, fire drills, etc.- (a) The first-aid and other fire fighting equipment to be provided as required in sub- rules(11) and (12) shall be in charge of a trained responsible person. (b) Sufficient number of persons shall be trained in the proper handling of fire fighting equipment as referred to in clause (a) and their use against the types of fire for which they are intended to ensure that adequate number of persons are available for fire fighting both by means of first-aid fire fighting equipment and others. Wherever vehicles with towing attachment are to be provided as required in clause (d) of sub- rule (12) sufficient number of persons shall be trained in driving these vehicles to ensure that trained persons are available for driving them whenever the need arises. (c) Fire fighting drills shall be held as often as necessary & at least once in every period of two months. (14) Adequate number of automatic sprinklers and fire hydrants shall be provided, in addition, and not in substitution of the requirements in sub-rules (11) and (12). (15) If the Competent Authority is satisfied in respect of any factory or any part of the factory that owing to the exceptional circumstances such as inadequacy of water supply or infrequency of the manufacturing process or for any other reason, to be recorded in writing, all or any of the requirements of the rules are impracticable or not necessary for the protection of workers, it may by order in writing (which it may at its discretion revoke)exempt such factory or part of the factory from all or any of the provisions of the rules subject to conditions as it may by such order prescribe. Atomic Energy Factory Rules, 1996 61 Rule 42(Sch.I) SCHEDULE I First Aid Fire Fighting Equipments 1. The different type of fires and first aid fire fighting equipments suitable for use on them are as under: Class of Fire Suitable type of Appliances A. Fires in ordinary combustibles (wood, vegetable fibres, paper & the like) Chemical Extinguishers of Soda-acid, Gas/expelled Water and anti-freeze types and water buckets. B. Fires in flammable liquids, paints, grease, solvents and the like Chemical Extinguishers of foam, Carbon dioxide and dry powder types and sand buckets C. Fires in gaseous substances under pressure Chemical Extinguishers of carbon dioxide and dry powder types D. Fires in Reactive Chemicals, active metals and the like Special type of dry powder extinguishers and sand buckets E. Fires in electrical equipments Chemical extinguishers of carbon dioxide and dry Powder type & sand buckets 2. One 9 litres water bucket shall be provided for every 100 sq.m. of the floor area or part thereof and one 9 litres water type extinguisher shall be provided to six buckets or part thereof with a minimum of one extinguisher and two buckets per compartment of the building. Buckets may be dispensed with, provided supply of extinguishers is double that indicated above. 3. Acceptable replacements for Water buckets and water type extinguishers in occupancies where Class B fires are anticipated, are as under: Atomic Energy Factory Rules, 1996 62 Rule 42 (Sch.I) Buckets of water Water type Extinguishers Acceptable Replacements For one bucket For three buckets For each 9 ltrs.(or 2 gallons) Extinguishers 1 2-a 2-b 3 Dry sand 1 bucket 3 buckets - Carbondioxide Extinguishers 3 kg. (or 7 lbs) 9 kg. (or 20 lbs) (In not less than 2 extinguishers) 9 kg.(or 20 lbs) Dry powder 2 kg. (or 5 lbs) 5 kg. (or 11 lbs) (In one or more extinguishers) 5 kg. (or 11 lbs) Foam extinguishers 9 litres(or 2 gallons) 9 litres (or 2 gallons) 9 litres (or 2 gallons) 4. The following provisions shall be complied with where Class E fires are anticipated: (a) For rooms containing electrical transformers, switchgears, motors and/or other electrical apparatus only, not less than two kg. Dry Powder or Carbon Dioxide type extinguishers shall be provided within 15 m. of the apparatus. (b) Where motors and/or other electrical equipment are installed in rooms other than these containing such equipment only, one 5 kg. Dry Powder or Carbon Dioxide Extinguisher shall be installed within 15 m. of such equipment in addition to the requirements mentioned at (3) and (4) above. For this purpose the same extinguisher may be deemed to afford protection to all apparatus within 15 m. thereof. (c) Where electrical meters are installed on platforms, one 2 kg. Dry Powder or Carbon Dioxide type extinguisher shall be provided on or below each platform. In case of a long platform with a number of motors, one extinguisher shall be acceptable as adequate for every 3 motors on the common platform. The above requirements will be in addition to the requirements mentioned at item (3) & (4) above. Atomic Energy Factory Rules, 1996 63 Rule 42 (Sch.I-II) 5. The first aid fire fighting equipments shall be so distributed over the entire floor area that a person has to travel not more than 15 m. to reach the nearest equipment. 6. Selection of sites for the installation of first aid fire fighting equipments - (a) While selecting sites for first aid fire fighting equipments, due consideration shall be given to the nature of the risk to be covered. The equipments shall be placed in conspicuous positions and shall be readily accessible for immediate use in all parts of the occupancy. It should always be borne in mind while selecting sites that first aid fire fighting equipments are intended only for use on incipient fires and their values may be negligible if the fire is not extinguished or brought under control in the early stages. (b) Buckets and extinguishers shall be placed at convenient and easily accessible locations either on hangers or on stands in such a way that their bottom is 750 mm. above the floor level. 7. The operating instructions of the extinguishers shall not be defaced or obliterated. In case the operating instructions are obliterated or have become illegible due to passage of time, fresh transfers of the same shall be obtained from the manufacturers of the equipments and affixed to the extinguishers. SCHEDULE II EQUIPMENT TO BE PROVIDED WITH TRAILER PUMP For light trailer pump of capacity of 680 ltrs./min. Type of equipment Nos. Armoured suction hose of 9 meters length, with wrenches. 1 Metal suction strainer. 1 Basket strainer. 1 Two-way suction collecting-head. 1 Suction adaptor. 1 Unlined or rubber lined 70 mm delivery hose of 25 meters length complete with quick-release couplings. 10 Atomic Energy Factory Rules, 1996 64 Rule 42 (Sch.II) Dividing breaching-piece. 1 Branch-piece with 15 mm nozzles. 2 Diffuser nozzle. 1 Standpipe with blank cap. 1 Hydrant key. 1 Collapsible canvas buckets. 4 Fire hook preventor with cutting edge. 1 25 mm manila rope of 30 meters length. 1 Extension ladder of 3 m (where necessary) 1 Heavy axe. 1 Spade. 1 Pick axe. 1 Crowbar. 1 Saw. 1 Hurricane lamp. 1 Electric torch. 1 Pair of rubber gloves. 1 For large trailer pump of a capacity of 1800 litres/minute Type of equipment Nos. Armoured suction hose of 9 meters length, with wrenches. 1 Metal strainer. 1 Basket strainer. 1 Three-way suction collecting-head. 1 Suction adaptor. 1 Unlined or rubber lined 70 mm delivery hose of Atomic Energy Factory Rules, 1996 65 Rules 42(Sch.II)-43 25 meters length complete with quick-release couplings. 14 Dividing breaching-piece. 1 Collecting breaching-piece. 1 Branch pipes with one 25 mm, two 20 mm and one diffuser nozzles. 4 Stand pipe with blank caps. 2 Hydrant keys. 2 Collapsible canvas buckets 6 Coiling hook (preventor) with cutting edge. 1 50 mm manila rope of 30 meters length. 1 Extension ladder of 9 meters length (where necessary). 1 Heavy axe. 1 Spade. 1 Pick axe. 1 Crowbar. 1 Saw. 1 Hurricane lamp. 1 Electric torch. 1 Pair of rubber gloves. 1 Note:- If it appears to the Competent Authority that in any factory the provision of breathing apparatus is necessary it may by order in writing require the occupier to provide suitable breathing apparatus in addition to the equipment for light trailer pump or large trailer pump as the case may be.

Previous and next

All provisions of Atomic Energy (Factories) Rules, 1996

Questions people ask

Is rule 42 of Atomic Energy (Factories) Rules, 1996 still in force?

No repeal of Atomic Energy (Factories) Rules, 1996 is recorded.