Rule 40, Atomic Energy (Factories) Rules, 1996: MINIMUM DIMENSIONS OF MANHOLES

Atomic Energy (Factories) Rules, 1996 - Rule 40

Text of rule 40

MINIMUM DIMENSIONS OF MANHOLES

40. MINIMUM DIMENSIONS OF MANHOLES.- Every chamber, tank, vat, pipe, flue or other confined space, which persons may have to enter and which may contain dangerous fumes to such an extent as to involve risk of the persons being overcome thereby, shall unless there is other effective means of egress, be provided with a manhole which may be rectangular, oval or circular in shape, and shall have the following dimensions as minimum, namely:- Rectangular shape- 50 cm X 30 cm Oval shape - Major & minor axis diameters 50 cm. and 30 cm. respectively. Circular shape - 50 cm diameter

Previous and next

All provisions of Atomic Energy (Factories) Rules, 1996

Questions people ask

Is rule 40 of Atomic Energy (Factories) Rules, 1996 still in force?

No repeal of Atomic Energy (Factories) Rules, 1996 is recorded.