LawGrids logoLAWGRIDS.ORG

Form 7, Atomic Energy (Factories) Rules, 1996: Form - 7

Atomic Energy (Factories) Rules, 1996 - Form 7

Text of form 7

Form - 7

Form - 7 ITEM FIELD PERFORMANCE REPORT ( See rule 60) 1. Name of the Factory : 2. Item : .1 Identification : .2 Manufacturer : .3 Number of items of the type : .4 Date of manufacture : .5 Date of modification/reconditioning : .6 Date first placed in use : .7 Cumulative operating time since above : .8 Date & place where used after 2.5 : .9 Date/ cumulative operating time since above : .10 Cumulative time-Non use (Storage/Maintenance) : 4. Operating environment : .1 Temperature Range : .2 Relative humidity range : .3 Nature of atmosphere A.C./Clean/Dusty/Corrosive/.... : .4 Vibration level : 5. Mode of operation Continuous/Intermittent/Standby/........... : Atomic Energy Factory Rules, 1996 ( 2 ) 6. Item failure information : .1 Symptoms of failure : .2 Failure detected during Operation / Periodic check / Preventive maintenance : .3 Functions affected by failure : .4 Failure cause : Inherent/Misuse/ Maintenance induced/ : External to item/ Secondary/Unknown : 7. Item failure analysis and correction : .1 List of failed parts : .2 List of replaced parts : .3 Adjustments made : 8. Total active downtime : 9. Total downtime : 10. Any other information : Signature: Date: Name : Designation: Atomic Energy Factory Rules, 1996 Atomic Energy Factory Rules, 1996

Previous and next

All provisions of Atomic Energy (Factories) Rules, 1996

Questions people ask

Is form 7 of Atomic Energy (Factories) Rules, 1996 still in force?

No repeal of Atomic Energy (Factories) Rules, 1996 is recorded.