Development Regulations for CMA
Regulations made under An Ordinance to make Special Provisions for Chennai Metropolitan Planning Area for a period of one year and for matters connected therewith or incidental thereto.
This text is shown as one document.
Full text
SECOND MASTER PLAN
FOR
CHENNAI METROPOLITAN AREA, 2026
Volume II
Development Regulations
(Originally approved by the Government of Tamil Nadu in G.O.Ms. No. 190
H&UD Dept., dated 2.9.2008, and notified in the Tamil Nadu Government
Gazettee Extraordinary No.266, Part II-Section 2 dated September 2, 2008 )
Amendments incorporated upto May, 2013
Chennai Metropolitan Development Authority
Thalamuthu - Natarajan Building,
No.1 Gandhi - Irwin Road, Egmore, Chennai - 600 008.
Contents
DR No. Title Page No.
1 Short title 1
2 Definition 1
3 Written Permission for development 4
4 Manner of obtaining permission 5
4(4) Scrutiny fees 6
4(5) Completion Certificate 6
5 Development to be in conformity with these regulations 7
6 Designation of use in Master Plan or Detailed
Development Plan
8
7 Requirement for site approval 9
8 Proposed width of roads 10
9 Transferable Development Rights 10
9A Special Transferable Development Rights 11
10 Proximity to quarries and crushers 11
11 Structures in set back spaces 11
12 Boundaries of land use zones 12
13 Repeal and Savings 13
14 Primary Residential use zone 13
15 Mixed Residential use zone 14
16 Commercial use zone 15
17 Industrial use zone 16
18 Special and Hazardous Industrial use zone 16
19 Institutional use zone 17
20 Open Space and Recreational use zone 18
21 Urbanisable use zone 18
22 Non-Urban use zone 18
DR No. Title Page No.
23 Agricultural use zone 19
24 (2) Ecologically sensitive areas 20
24 (2)(a) CRZ area 20
24 (2)(b) Aquifer recharge area 20
24 (2)(c) Catchment area 20
24 (3) Development prohibited areas 20
24 (3)(a) Area around Indian Air Force station 20
24 (3)(b) Pallikkaranai Swamp area 20
24 (4) Areas of special character 20
24 (4)(a) MRTS influence area 20
24 (4)(b) I.T Corridor 21
24 (4)(c) Area around Airport/Aerodrome 21
24 (5) Natural hazard prone areas 21
24 (6) Green Belt along Poonamallee Bye pass and Redhills
Bye pass roads
21
25 Planning Parameters 22
25-Table (1) Ordinary Residential Buildings and other small
developments
22
25-Table (2) Ordinary Commercial Buildings and other small
developments
23
25-Table (3) Cottage industries, Green industries and Orange
industries upto 30 H.P
25
25-Table (4) Green industries, and Orange industries upto 200 HP
[permissible in industrial use zone]
26
25-Table (5) Industries exceeding 200 H.P 27
25-Table (6) Special and Hazardous Industries 28
25-Table (7) Institutional buildings 29
25-Table (8) Religious buildings with floor area less than 300 sq.m.
and height not exceeding G+1 floors
30
25-Table (9) Transport Terminals such as Bus Terminals, Bus
stands, Railway stations, Truck terminals, container
terminals
31
DR No. Title Page No.
26 Regulation for Special Buildings 32
27 Regulation for Group developments 39
28 Special rules for multi-storeyed Buildings 43
29 Layout and sub-division regulations 49
30 Architectural Control 52
31 Conservation of buildings of historical or architectural
interest
52
32 Tree preservation 52
33 These Regulations to prevail 52
34 Identification of boundaries 53
35 Discretionary Powers 53
36 Premium FSI 53
37 Delegation of Powers 54
38 Penalties 54
39 Transitary provisions 54
Annexures
1 Annexure I
FORM-A: Application for Planning Permission
for laying out the land for building purposes
55
2 Annexure II
FORM-B: Application for Planning Permission
for development of land and buildings other
than those covered under FORM A
58
3 Annexure III
FORM C: Form of Undertaking to be executed
individually by the Land Owner or Power of
Attorney Holder or Builder or promoter.
61
4 Annexure IV
Proposed Rights of Way and set back lines for
major network of roads
63
5 Annexure V
List of cottage industries
70
6 Annexure VI
Industries classified as “Green”
73
7 Annexure VII
Industries classified as “Orange”
75
8 Annexure VIII
List of industries permissible in Special and
Hazardous Industrial Zone
77
9 Annexure IX
Areas set apart for Multi- Storeyed buildings
80
10 Annexure X
Notification on Coastal Regulation Zone
81
11 Annexure XI
Regulation for developments in the Aquifer
Recharge Area
94
12 Annexure XII
Regulations for Redhills Catchment area
98
13 Annexure XIII
Rules for Information Technology Park
100
14 Annexure XIV
MRTS Influence area
102
15 Annexure XV
Civil Aviation requirements for construction in
the vicinity of an aerodrome
103
16 Annexure XVI Parking requirements
107
17 Annexure XVII
Corridor width
115
18 Annexure XVIII
Spaces excluded from FSI and Coverage
computation
116
19 Annexure XIX
Rain Water Conservation
117
20 Annexure XX
Reservation of land for recreational purposes in
cases of special buildings/ group
developments/ multistoreyed building
developments
123
21 Annexure XXI Regulation for the grant of TDR
125
22 Annexure XXII
Provisions for persons with disabilities
128
23 Annexure XXIII Solar Energy Capture
129
24 Annexure XXIV
Electrical Rooms
130
25 Annexure XXV Special Rules for conservation of Heritage
Buildings
132
26 Annexure XXV-A Special Regulations for parking at upper floors
above a stilt parking floor in Special
Buildings/Group Developments / Multi Storied
Buildings.
136
27 Annexure XXVI
List of Chennai Corporation Divisions and
Villages in Chennai Metropolitan Area
138
Villages included in Chennai Corporation
154
28 Annexure XXVII Regulation for the grant of Special TDR for
slum dwellers
157
29 Maps Chennai City – Street Alignment 161
CMA – Street Alignment 163
Chennai City – Continuous Building Areas 165
CMA – Coastal Regulation Zone Area 167
CMA – Aquifer Recharge Area 169
CMA – Redhills Catchment Area 171
CMA – Prohibited Area around IAF Station 173
CMA – Pallikaranai Swamp Area 175
CMA – I.T. Corridor 177
Chennai City – MRTS Influence Areas 179
CMA – Transitional Areas & Trough around
Runways
181
30 Others Guidelines for the Premium FSI 183
Guidelines for Transfer of Development Rights 184
Guidelines for Special Transfer of Development
Rights
191
1
Development Regulations for Chennai Metropolitan Area
1. Short title:
(1) These regulations may be called Development Regulations for Chennai Metropolitan
Area.
(2) It extends to the whole of Chennai Metropolitan Area.
2. Definition
(1) Access means way to a plot or a building.
(2) Accessory Use means any use of the premises subordinate to the principal use and
customarily incidental to the principal use.
(3) Act means the Tamil Nadu Town and Country Planning Act 1971 (Tamil Nadu Act
35 of 1972) as amended from time to time.
(4) Alteration means a change from one occupancy to another, or a structural change,
such as an addition to the area or height, or the removal of part of a building, or any
change to the structure, such as the construction of, cutting into or removal of any
wall, partition, column, beam, joist, floor or other support, or a change to or closing
of any required means of ingress or egress or a change to the fixtures or equipment.
(5) Assembly Building means any building or part of a building, where 50 persons or
more congregate or gather for amusement, recreation, social, religious, patriotic,
civil, travel and similar purposes. These shall include theatres, motion picture
houses, assembly halls, auditoria, exhibition halls, museums, skating rinks, large
gymnasiums, places of worship, dance halls, club rooms, passenger stations and
terminals of air, surface and marine, public transportation services, stadia, etc.,
(6) Authority means the Chennai Metropolitan Development Authority constituted
under the Act.
(7) Balcony – A cantilever projection, with a handrail or balustrade or a parapet, to
serve as sitting out place.
(8) Basement or Cellar – The lower storey or storeys of a building below or partly below
ground level with majority of its headroom below ground level.
(9) Building includes
- a house, out-house, stable, latrine, godown, shed, hut, wall (other than a
boundary wall) and any other structure whether of masonry, bricks, mud, wood,
metal or any other material whatsoever;
- a structure on wheels or simply resting on the ground without foundation;
- a ship, vessel, boat, tent, van and any other structure used for human
habitation or used for keeping or storing any article or goods; and
- the garden, grounds, carriages and stables, if any, appurtenant to any building.
(10) Building Line means a line behind the street-alignment and to which the main wall
of a building abutting on a street may lawfully extend
(11) Security cabin means a non-residential enclosure constructed of non-load bearing
partition.
(12) Canopy/ portico/porch-means cantilever projection at lintel level or ground floor
roof level over an entrance of a building.
(13) Chimney - An upright shaft containing one or more flues provided for the
conveyance to the outer air of any product of combustion resulting from the
2
operation of heat production appliance or equipment employing solid, liquid or
gaseous fuel.
(14) Competent Authority means the Chennai Metropolitan Development Authority or a
local authority concerned to whom the Chennai Metropolitan Development
Authority has delegated the powers for issue of Planning Permission.
(15) Corridor means a common passage or circulation space within a building.
(16) Continuous building means buildings constructed without any side set back. Row
type housing also falls in to this category.
(17) Covered Area – Ground area covered by the building above the plinth level and
includes parts of the building projecting out in other storey (including basement
floor levels).
(18) Development means the carrying out of all or any of the works contemplated in a
regional plan, master plan, detailed development plan or a new town development
prepared under Town and Country Planning Act 1971, [as defined in clause 13 of
section 2 of the Tamilnadu Town and Country Planning Act 1971 including
subdivision, layout, reconstitution or amalgamation of land] and shall include the
carrying out of building, engineering, mining or other operations in, or over or under
land, or the making of any material change in the use of any building or land:
Provided that for the purpose of the Town and Country Planning Act 1971, the
following operations or uses of land shall not be deemed to involve development of
the land that is to say,
i. the carrying out of any temporary works for the maintenance, improvement or
other alteration of any building, being works which do not materially affect the
external appearance of the building;
ii. the carrying out by a local authority of any temporary works required for the
maintenance or improvement of a road, or works carried out on land within the
boundaries of the road;
iii. the carrying out by a local authority or statutory undertaker of any temporary
works for the purpose of inspecting, repairing or renewing any sewers, mains,
pipes, cables or other apparatus, including the breaking open of any street or
other land for that purpose;
iv. the use of any building or other land within the cartilage of a dwelling house for
any purpose incidental to the enjoyment of the dwelling house as such; and
v. the use of any land for the purpose of agriculture, gardening or forestry
(including afforestation) and the use for any purpose specified in this clause of
this provision of any building occupied together with the land so used.
(19) Drain – A conduit or channel for the carriage of storm water, sewage, wastewater or
other water borne wastes.
[20] Dwelling Unit – An independent housing unit with separates facilities for living,
cooking and sanitary requirements, and may be a part of a building.
(21) Floor Space Index (FSI) means the quotient obtained by dividing the total covered
area (plinth) on all floors excepting the areas specifically exempted under these
regulations (given in Annexure XVIII) by the plot area which includes part of the site
used as exclusive passage.
FSI = Total covered area on all floors
Plot area
(22) Farm House - means a building constructed as an incidental use to an agriculture
or horticulture farm. Any building constructed not associated with farm activities
shall not be construed as a “farm house” for the purposes of these Regulations.
3
(23) Group Development means accommodation for residential or Commercial or
combination of such activities housed in two or more blocks of buildings in a
particular site irrespective of whether these structures are interconnected or not.
Any inter link between the structures in terms of connecting corridors shall not be
construed as making any two structures into one block. However, if these blocks
are connected solidly atleast for one-third the width of any one block on the
connecting side, then such blocks shall be construed as a single block.
(24) Height of the Building means the height measured generally from the formed
ground level abutting the road / passage [excluding ramp if any within the plot]
provided that stair-case head rooms, lift rooms, elevated tanks and also WC (with
floor area not exceeding 10sq.m.) above topmost floor, and also architectural
features, and parapet walls of height up to 1 meter shall not be included in
calculating the height of building. In cases where earth filling is made/proposed
within the site above the average level of the abutting street/road, then the height of
building shall be reckoned from the filled up ground level around the building
provided such filling does not exceed 1 meter above the average level of the abutting
street/road. If the height measured from the top of such filling is 15.25 metres,
such building shall not be construed as a Multi-storeyed building.
(25) Layout means division of land into plots exceeding eight in number.
(26) Local Authority or Local Body means a Municipal Corporation of Chennai,
Municipality, Town Panchayat, Panchayat Union or Village Panchayat within the
Chennai Metropolitan Area.
(27) Mezzanine floor is an intermediate floor between two floors above ground level
subject to the following:-
a) the area of mezzanine is restricted to 1/3rd area of that floor;
b) the height of the mezzanine floor shall be minimum 2.2 metres for non-habitable
purposes and 2.5 metres for habitable purposes; and
c) the head room height of the remaining part of the said floor shall be the total of
the height of the mezzanine floor and the space below the mezzanine floor.’
(28) Multi-storeyed Buildings means buildings exceeding 4 floors and or 15.25 meters
in height. [However in cases of hospitals, buildings not exceeding 4 floors and or
17metres in height will be construed as non multi-storeyed buildings.]
(29) Ordinary building means a residential or commercial building, which does not fall
within the definition of special building, group development or multi-storeyed
building;
(30) Parking space means an area covered or open, sufficient in size to park vehicles
together with a driveway connecting the parking lot with road or street and
permitting ingress or egress of the vehicles.
(31) Passage means circulation space on land leading from a street/road to the plot/site.
(32) Plinth Area - The built up covered area measured at the floor level of the basement
or of any storey
(33) Plot/site Area - means the area of contiguous parcel of land enclosed by definite
boundaries over which the applicant has legal right for development. If the extent of
plot differs as per site conditions, PLR extract/patta and registered ownership
document, then for application of FSI and plot coverage regulations, lowest of the
same (excluding any encroachment) will be counted. For application of setback
regulation the inner boundary arrived excluding any encroachment or the part of
the land for which the applicant/developer do not have the right over it will be the
basis.
(34) Plot coverage- means the extent to which the plot is covered with a building or
structure (12-noon shadow) and this is expressed as percentage of the ratio of the
4
built up area to the plot area (including part of the site used as exclusive passage).
Floor area exempted from the computation of plot coverage is given in Annexure
XVIII.
(35) Road/Street width- means whole extent of space within the boundaries of the
road/street measured at right angles to the course of direction of such road/street.
(36) Row Housing / Row type Building (Continuous Building) – means a row of houses
/ buildings with only front, rear and interior open spaces where applicable.
(37) Set back- means open space across front or sides or rear of a plot between the
building and street alignment or boundary of the plot as the case may be.
(38) Site / plot- means contiguous parcel of land enclosed by definite boundaries.
(39) Section means a section of the Act.
(40) Special Building means
a) a residential or commercial buildings with more than 2 floors; or
b) a residential building with more than six dwelling units; or
c) a commercial building exceeding a floor area of 300 square metres:
Provided that any construction in the second floor as an addition to an individual
existing ground and first floor building which is three years old shall not be
construed as a “Special Building”
(41) Stilt floor means a part or whole of floor at ground level or the height above the
ground level described in these regulations where the building is on stilts.
If the stilt-parking floor is to the standards exemptable for FSI it will not be counted
as a floor for the purpose of defining special building or multistoreyed building
(42) Street Alignment means a line dividing the lands comprised in and will be forming
part of the street from the adjoining land.
(43) Sub-division means division of land into plots not exceeding eight in number
(44) Verandah - A covered area with at least one side open to the outside with the
exception of 1 m high parapet to be provided on the open side.
(45) Other terms used in these rules unless the context otherwise requires shall have
the meaning as defined in section 2 of the Act.
3. Written Permission for development
(1) No person shall carry out any development as defined in Clause (13) of Section-2 of
the Tamil Nadu Town and Country Planning Act – 1971 (Tamil Nadu Act – 35 of
1972) including subdivision / layout or reconstitution or amalgamation of land
without the written permission of the Authority or such other Executive Authority of
Local Body or Agency or Person to whom this power has been delegated by the
Authority.
(2) Any site approval or Planning Permission for any development under these
regulations shall not absolve the applicant of his responsibilities to get clearance or
permission under other Acts and Rules.
(3) For the uses specified in Items (a) to (e) of Clause (13) of Section-2 of the Act, the
Planning Permission does not arise, as they do not constitute “Development” as
defined in the Act.
5
4. Manner of obtaining permission
(1) For the purpose of obtaining Permission, the applicant who should be the owner of
the land or leaseholder or power of attorney holder who has right over the land to
develop shall submit an application in the prescribed form to the Member-Secretary
of the Authority or to such other authority or person as designated by the Authority,
(a) Form-A
An application in Form-‘A’ accompanied by evidence of ownership, plans,
specifications, etc., mentioned therein in case of subdivision / layout or
reconstitution or amalgamation of land for building purposes.
(b) Form -B
An application in Form-‘B’ accompanied by evidence of ownership, detailed
plans, specifications, site plan, and topo plan showing existing developments to
a radius of 100 metres drawn to a scale of 1:500 and such other details as may
be prescribed from time to time, in the case of development of land and
buildings, change of land and building use and in the case of site approval.
To know whether the particular type of development contemplated is permissible
or not, it would be sufficient for him to provide the minimum required
information as indicated in the form and resubmit the application to the
Authority directly. A fee as may be prescribed by the Authority shall be remitted
to the Authority along with such application. The information furnished in reply
to such enquiry will not constitute a Planning Permit.
(c) Form-C
An undertaking in Form ‘C’ in the case of developments such as Special
Buildings, Group Developments, Multi-storeyed Buildings and other
developments as may be decided by the Authority, obtained from the Owner,
Builder, Promoter and Power of Attorney holder that they are jointly and
severally responsible to carry out Developments in accordance with permission
granted and for payment of Development charges, Security deposit amount and
all other charges as applicable and levied by Chennai Metropolitan Development
Authority and also liable for penal actions for developments made in
contravention of these regulations and the conditions prescribed in the Planning
Permit.
(d) The designs and plans of building shall be prepared and signed by
Architect/Engineer/Licensed Surveyor and other professionals as prescribed by
the local body concerned in their Act/Building Rules.
(2) If the Plan and information furnished by the applicant under sub-regulation-1 above
do not provide all the particulars necessary to process the application satisfactorily,
the Authority or the person to whom the power has been delegated by the Authority
may within 30 days from the date of receipt of Plans/Applications require the
production of such further particulars and details as it deems necessary.
If the plan and the information furnished by the Applicant are found to satisfy the
requirements of these regulations, and the matters stated in Section 49(2) of the
Act,
(a) The written permission shall be issued by the Authority or person designated for
the purpose by the Authority.
(b) While granting permission the Chennai Metropolitan Development Authority or
other authority or person to whom the Authority had delegated the powers may
impose such restrictions and conditions, which may be necessary under these
regulations.
6
(3) When the permission is refused, the reasons for refusal shall be recorded and
furnished to the applicant as provided in Section 49(3) of the Act.
(4) Scrutiny fees
(a) Scrutiny Fee means a fee for scrutinizing the applications, collected from the
applicant along with the plan or revised plan or modified plan submitted by the
applicant.
(b) While accepting Planning Permission applications for developments exceeding
300sq.m in floor area and also requests for Reclassifications, the Chennai
Metropolitan Development Authority or other authority or person to whom the
Authority had delegated its power shall collect a Scrutiny Fee at the rates given
below:
(i) (a) Plans submitted along with PP applications per sq.m. of
floor area of the building
Rs.1.50
(b) Ist revised plan per sq.m. of floor area of the building Rs.0.75
(c) 2nd revised plan per sq.m. of floor area of the building Rs.0.40
(d) 3rd revised plan per sq.m. of floor area of the building Rs.0.20
(e) Subsequent revised plans Nil
(ii) Layouts/subdivisions, reconstitutions per sq.m. of land area Rs. 0.075
(iii) Re-classifications (lump sum) Rs.1500
However, Charitable Institutions/Organisations serving the poor, orphanages,
Institutions for mentally retarded children which are run for the welfare of the
Society, while submitting the revised plan are exempted from the levy of
Scrutiny Fee, wherever constructions proposed by them are for charitable
activities and not for commercial exploitations (Scrutiny Fees are leviable for the
Plans submitted by these institutions for the first time along with PP
applications).
(c) Other amount payable by the applicant in cases of PP applications for sub-
divisions/layouts and request for reclassifications are,
(i) Sub-divisions/layouts preparation charges per sq.m.
Rs.0.25
(ii) Cost of publication of reclassification in Newspapers
and Govt. gazette. (if the actual cost exceeds the said
amount, the excess amount is also payable by the
applicant)
Rs.7500
(5) Completion Certificate
(a) The Applicant/Owner/Builder/Promoter/Power of Attorney Holder and any
other Person who is acquiring interest shall not put the building to use without
obtaining Completion Certificate from CMDA for ‘Special buildings’, ‘Group
Developments’, ‘Multi-storeyed Buildings’ and Institutional buildings (exceeding
300M2 in floor area) and such other developments as may be notified by the
Chennai Metropolitan Development Authority from time to time.
(b) The Applicant/Owner/Builder/Promoter/Power of Attorney holder and any
other person who is acquiring interest shall submit application in complete
7
shape for issue of Completion Certificate before probable date of completion, and
CMDA/Local Body concerned, which had issued PP, shall dispose off such
application.
5. Development to be in conformity with these regulations
(1) No developments shall be in contravention of these Regulations.
(2) No land, premises or building shall be developed, constructed, altered,
reconstructed, subdivided, amalgamated, reconstituted, laid-out, changed or put to
use which is not in conformity with the provisions of these regulations.
(3) In the case of an area comprised in a Detailed Development Plan approved under
the Act, the Developments therein shall be in conformity with that Detailed
Development Plan.
Provided that where for a road, street alignment is not prescribed in Detailed
Development Plan, but it is prescribed in the Master Plan, then street alignment in
Master Plan shall apply.
Provided further that in cases where an area is declared as Continuous Building
Area either in Master Plan or in Detailed Development Plan, the area shall be taken
as Continuous Building Area and developments therein shall be regulated
accordingly; however, Continuous Building Area parameters shall not apply to plots
in approved layout areas unless specifically earmarked for continuous building
developments.
(4) All detailed Town Planning Schemes sanctioned under the Town Planning Act 1920
(Tamil Nadu Act-7 of 1920) shall stand superceded by the Master Plan/Detailed
Development Plan approved for that area. All developments therein shall be
regulated with reference to the Land Use classification indicated in the Master
Plan/Detailed Development Plan for that area and development regulations.
(5) Developments in respect of Detailed Development Plans approved/consented to by
the Government shall be regulated with reference to the equivalent land use
classification indicated below and development regulations.
Sl.No Use Classification in Detailed
Development Plan
Use classification in these
Regulations
1 Primary Residential Primary Residential
2 Mixed Residential Mixed Residential
3 Commercial Commercial
4 Light Industrial Industrial
5 General industrial Industrial
6 Special and Hazardous Industrial Special and Hazardous Industrial
7 Institutional Institutional
8 Open Space & Recreational Open Space & Recreational
9 Non-Urban Non-Urban
10 Agricultural Agricultural
11 -Nil- Urbanisable
8
6. Designation of use in Master Plan or Detailed Development Plan
(1) Where use of a site or premises is specifically designated (not broad land use zoning)
in the Detailed Development Plan/Master Plan, it shall be used only for the specific
purpose so designated, unless the land use of the site is varied as provided in the
Act.
(2) Where the use of the site or premises is not specifically designated in the Detailed
Development Plan/Master Plan, it shall be used for the uses/activities permissible
in the land use zone in which the site or premises falls as per the Detailed
Development Plan / Master Plan.
Provided that and subject to the provisions of the Madras city Municipal
Corporation Act 1919, (Tamil Nadu Act IV of 1919), Tamil Nadu District
Municipalities Act 1920 (Tamil Nadu Act V of 1920), and Tamil Nadu Panchayat Act
1994, any lawful use of the premises existing prior to 05.08.1975 (i.e. date of
coming into force of first Master Plan for Chennai Metropolitan Area) may continue.
Provided further that a non-conforming use (i.e. an use which under these
regulations becomes not permissible at the site) shall not be extended or enlarged.
Explanation:
Improvements to building or machinery intended to make the operations more
economical, cleaner, less noisier and to provide amenities to workers which do not
add to the manufacturing capacity as may be specially approved by the Authority
shall not be deemed to be extension or enlargement.
Provided also that it will be open to the Authority to order at any time the
discontinuance or continuance subject to such restrictions and conditions as may
be imposed by on an existing use, which is non-conforming.
(3) Where for an area both Master Plan and Detailed Development Plan were / are
sanctioned, the designated use shall be as shown in the latest development Plan.
(4) Where for an area, a Detailed Development Plan has been prepared and the consent
of the Government has been given under Section-26 of the Act, the provisions of
that Detailed Development Plan shall apply.
(5) Where for an area, a detailed lay-out plan for land development has been prepared
and approved by the Authority or such other Executive Authority of Local Body or
Agency or person to whom/which the power has been delegated by the Authority,
the land use shown on such Lay-out Plan shall be applicable and the developments
in the area shall be regulated according to these regulations.
Provided that if the layout plan was approved prior 5.8.1975 the higher order land
use zoning of Master Plan/Detailed Development Plan shall be applicable for the
plot.
Provided further that if land use is varied under section 32 sub-section (4 )of the
Act, subsequent to layout approval then the reclassified land use is applicable for
the plot in the approved layout.
In all other cases of development, the provisions of these regulations shall apply.
(6) Areas classified as 'Settlements' (village Nathams) by Revenue Department are
deemed to have been zoned as Mixed Residential use zone.
Provided any land in that natham area has been zoned for a higher order zone in the
Master Plan/DDP, then the zoning shown in the Master Plan/DDP shall be
applicable.
The ascending order of Zoning is Primary Residential, Mixed Residential,
Commercial and Industrial for the purpose of this regulation.
9
(7) In areas designated for Primary Residential Use in Master Plan/Detailed
Development Plan, (to be read with the sub regulation (5) above), sites abutting and
gaining access from roads of width 12 m. and above, but less than 18 m. are
deemed to have been zoned for mixed residential use zone.
(8) In areas designated for Primary Residential and / or Mixed Residential Use zone in
the Master Plan/Detailed Development Plan. (to be read with the sub regulation 5
above), sites abutting and gaining access from roads of width 18 m. and above are
deemed to have been zoned for Commercial use zone.
(9) All areas set apart for Housing of Economically Weaker Section in the sanctioned
Schemes by Tamil Nadu Housing Board and areas declared as Slums by Tamil Nadu
Slum Clearance Board, slums improved by Tamil Nadu Slum Clearance Board
under Slum Improvement Scheme projects and also the EWS plots in the approved
layouts are deemed to have been declared as ‘EWS’ areas.
(10) When a site falls in different land use zones, then developments in that site shall be
made with reference to its conformity in each of the land use zones the site
comprises.
(11) Where more than one activity is existing or proposed in a building / a site, the space
regulations that govern the development shall be based on the dominant activity in
that building / site decided on the basis of the percentage of floor area used;
Provided that for buildings of public assembly the set back shall not be less than
6.0m in that part of the building.
(12) Where more than one type of development (such as Multi Storeyed Building, Group
Development etc.) is existing or proposed in a site,
(a) the set back shall be regulated with reference to the individual type of
development,
(b) the site extent, height of building, abutting road width shall be regulated with
reference to the highest order of development existing or proposed, and
(c) the Floor Space Index, coverage etc. shall be regulated with reference to the
dominant type of development (on the basis of floor area) within the site.
7. Requirement for site approval
(1) No development shall be made in a site unless the Authority approves the site for
the development.
(2) No piece of land shall be used as a site for the construction of a building for any
development if the Authority considers that:
(a) If the site is near a water body or a water course and the proposed development
is likely to contaminate the said water body or water course (or)
(b) If the site is likely to be inundated and satisfactory arrangement for proper
drainage is not possible
(c) If the site is a filled up tank or low lying or of made up of soil by depositing
rubbish or offensive matters and the proposal is likely to be affected by
dampness owing to the sub-soil water, unless ameliorative measures to the
satisfaction of the Authority are provided (or)
(d) If the site does not abut any existing public or private street forming part of a
Lay-out sanctioned under the provisions of the relevant Local Body Act,
conforming to the minimum width prescribed for various uses in these
regulations.
(e) No site in Municipal and Panchayat areas which is within a distance of 30
metres from a place declared and used as a burning or burial place/ground
shall be used for layout or sub division for human habitation (residential) shall
10
be built including addition / alteration / reconstructions with in 30 metres of
such declared burning or burial place/ground unless such burial/burning
place/ground was closed and remained closed for a period not less than 5 years
certified by the local body concerned.
(3) Minimum extent plot frontage and site dimensions under these regulations shall not
apply to the sites put to use and existed as such prior to 5.8.1975 evidenced by
Registered Documents provided that the then existing activity continue in cases of
other than residential activities. Further the said parameters shall not apply to the
vacant plot/site for residential use subdivided and registered prior to the said cut off
date.
(4) Reconstitution Deed:
If a development is proposed in more than one plot / site proposing amalgamation
or reconstitution of the individual sites to one site, then
(a) Reconstitution Deed in the format and manner prescribed by the Authority
shall be furnished by the applicant, and
(b) The proposed building shall fall on the dividing line of the plot / site, such that
the individual plot / site is not recognizable as a separate entity after execution
of the proposed development there on.
Provided that the sub-regulation (b) above shall not apply to amalgamation of a
plot / site to serve as access / passage;
Provided further that the above sub-regulations (a) and (b) shall not apply to
sub-division and layout applications where building proposals are not involved.
8. Proposed width of roads
Proposed right of way for all major roads together with set-back lines for them shall
be in accordance with details specified in Annexure IV (refer Map No.
MP-II/CMDA.6/2008 and Map No. MP-II/CMDA.7/2008).
(1) Notwithstanding anything contained in the Master Plan / Detailed Development
Plan or in these Regulations, with the prior approval of the Authority, the Executive
Authorities of the local bodies (viz. the Corporation or Municipalities concerned) may
under their Act provisions, prescribe street alignments with proposed road width
higher than those given in the Master Plan / Detailed Development Plan or in these
regulations.
9. Transferable Development Rights:
[1] In certain circumstances, the development potential of the whole or a part of the
plot/site may be separated from the land itself and may be made available to the
land owner in the form of Transferable Development Rights (TDR) excepting in the
case of existing or retention users, or any compulsory reservation of space for public
purpose or recreational use or EWS/social housing etc. in the cases of
subdivisions/ layouts/ special buildings/ group developments/ multi-storeyed
buildings or such other developments prescribed in these Development Regulations.
[2] Transferable Development Rights (TDR) shall apply to cases, where a private land is
required for-
(i) any road widening/new road formation as proposed in the Master Plan or DDP,
(ii) any traffic and transport infrastructure development such as bus stops/stands,
metro rail, MRTS etc.
(iii) any urban infrastructure development such as water supply, sewerage,
drainage, electricity, education, health, notified by the State Government
Department or Government Agency or local body.
11
[3] These rights may be made available and be subject to the regulations given in
Annexure XXI.
∗ [4] The Chennai Metropolitan Development Authority may formulate necessary
guidelines and decide on the principles including parameters to be followed for the
purpose of implementing the transfer of Development Rights (TDR) subject to the
regulations given in Annexure XXI.
Provided that in cases of slum (including pavement dwellers) rehabilitation schemes
on private lands executed by a private developer/society/NGO, the award of TDR for
FSI may be considered subject to such guidelines and conditions as may be decided
by the Government.
‡ 9-A. Special Transferable Development Rights :-
I. In cases of slums on waterways, road margins or any other land belonging to the
Government departments or agencies, as the slum dwellers do not own these lands,
the regulation for Transferable Development Rights is not applicable. Considering
the safety and enhancement, the slum dwellers who live in such areas need to be
resettled and rehabilitated. Further, in certain cases, some of the slum dwellers in
other non-objectionable areas also need to be resettled and rehabilitated, as the
lands are required for carrying out infrastructure projects or for any other public
purpose. In these cases, Special Transfer of Development Rights (Special TDR) for 30
square metres of floor area per slum dwelling resettled can be awarded to those
private developers who provide alternate accommodations to them, subject to the
Regulations given in the Annexure-XXVII.
II. The Chennai Metropolitan Development Authority may formulate necessary
guidelines, prescribe necessary forms and decide on the principles including
parameters to be followed for the purpose of implementing the said Special Transfer
of Development Rights subject to the Regulations given in the Annexure XXVII. ‡
10. Proximity to quarries and crushers
(a) No subdivision or layout shall be laid out or building for Residential,
Commercial, Industrial or Institutional or any structure for occupation shall be
constructed within 500m from an existing live quarry. (If a quarry is claimed as
abandoned, then a certificate from the local body or the licensing authority
concerned to that effect shall be produced when necessary).
(b) No subdivision or layout shall be laid out or residential or commercial or
institutional building shall be constructed within the radius of 500m from an
existing crusher.
(c) No crusher is permissible within a distance of 500m. from an existing residential
area.
11. Structures in set backspaces
(1) Unless or otherwise specifically provided for elsewhere in these regulations, no
structure shall be constructed within the minimum prescribed set back spaces
except the following:
(a) In cases of non-multistoreyed buildings (including ordinary buildings)-
A. Unsupported sunshade, wardrobes, balconies, and other projections from
the main walls, stated below so long as such structures do not fall within
minimum prescribed set-back spaces more than what is prescribed below:
(i) Sun-shades 0.60m
(ii) Non continuous wardrobes or built- in cub boards above
ground floor
0.60m
∗ Approved in G.O. Ms. No.141, H&UD dept, dated 06.08.2009 and published in TNGG on 26.08.2009
‡ Approved in G.O. Ms. No.161, H&UD dept, dated 15.07.2010 and published in TNGG on 18.08.2010
12
(iii) open non-continuous balconies (above ground floor) 1.20m
(iv) open service verandah to kitchen (above ground floor) 1.20m
(v) Architectural projections above ground floor 1.00m
(vi) Staircase open landing projections (not affecting
driveway)
1.00m
(vii) Cantilevered portico so long as it does not fall within 1.5m from the
street alignment or boundary of the site which ever is closer.
The items (iii) to (vi) above shall be permitted in the setback spaces provided a
minimum clearance of 0.5m for an ordinary building and 1.50m for a special
building / group development and for any other non- MSB from the property
boundary or street alignment whichever closer is made available;
Provided further that if non- continuous projecting structures stated above in
the set backs exceed 50% of the side/length of the building, then they shall be
taken as forming part of the main building, and shall not be allowed in the
minimum prescribed setback spaces.
B. Motor room of area not exceeding 2 sq.m. each and height not exceeding
1.8m, without affecting parking and driveway requirements.
(b) In case of ordinary buildings,
Open single flight or spiral staircase or open double flight staircase so long as
such structure do not fall within 0.50 m from the side boundary or 1 m. from
the rear or front boundary of the site or street alignment.
In case of Residential buildings in the Rear set back, structures like lavatory,
lumber room, garbage etc. not intended for human habitation and servant
quarters are permissible provided it doesn't occupy more than one third of the
plot width, 6m from rear boundary and 4 metres in height from ground level.
(c) A compound wall of height not exceeding 2.0m
(d) Watchman booth not exceeding 2.5m.x2.5m. in size at each gate and height not
exceeding 3 m.
(e) Gate pillars without or with arches with a min. headroom clearance of 5.50m
atleast to a width of 3.5m.
(f) Meter Rooms for meter boxes / electrical panels along the boundary wall or
external walls of the building with the projections not exceeding 0.60 meter from
the abutting walls and the open Transformer without affecting parking and drive
way, subject to the safety measures stipulated by TNEB.
Explanation:
(1) Any wardrobe or staircase projection stated above is countable for coverage and FSI
computation.
(2) In order to minimise traffic conflicts on to the abutting roads, the number of
vehicular entry /exits to site shall be kept minimum and it shall not exceed 2
numbers (i.e. one entry / one exit); Provided that an additional gate for every 50
metres frontage may be allowed in large sites if the frontage exceeds 50 metres.
12. Boundaries of land use zones:
(1) The different land use zones are located and bounded as shown in the land use
plans.
13
(2) Variations: For updated information on variations of Land Use made under section
32(4) of the Act and published subsequent to approval of the Master Plan/Detailed
Development Plan, the Counseling Counter in the Office of CMDA may be contacted.
13. Repeal and Savings
Anything done or any action taken including action against unauthorized/deviated
constructions, with reference to the D.C.R. under First Master Plan shall be deemed
to have been done or taken with reference to the corresponding provisions of these
Development Regulations under this Second Master Plan and continue in force
accordingly, unless and until superseded by any thing done or any action taken
with reference to this Second Master Plan Development Regulations.
Provided further that the action against unauthorized/deviated developments with
reference to first Master Plan D.C.R, taken by the Authority or person to whom the
Authority had delegated powers, immediately before commencement of these
regulations under Second Master Plan, may be continued irrespective of whether the
unauthorized/deviated development is in conformity with the Second Master Plan
DR. or not, as if this Second Master Plan Development Regulations have not come
into force, till the unapproved/deviated development is demolished or got
regularised on its merits with reference to these Development Regulations.
14. Primary Residential use zone
(1) In this zone buildings or premises shall be permitted only for the following purposes
and accessory uses. Permissible non-residential activity shall be limited to one in a
sub-division.
A. Normally Permissible Category.
i) Any residence including dwelling, detached, semi-detached, tenements or flats
and service apartments.
ii) Professional consulting offices and incidental uses thereto occupying a floor area
not exceeding 40 sq.m.
iii) Schools of Commerce including Tutorial Institutions not exceeding 100 sq.m. in
floor area.
iv) Petty shops dealing with daily essentials like retail sale of provisions, soft drinks,
cigarettes, news papers, etc., tea stalls, bakery, confectionary, retail shops,
mutton stalls, milk kiosk, cycle repair shops, tailoring shops, internet/computer
centers and ATMs etc. occupying a floor area not exceeding 40 sq.m.
v) Nursery schools, Primary Schools, Libraries and reading rooms.
vi) Parks, play grounds, farms, gardens, nurseries, including incidental buildings
thereon.
vii) Cottage industries listed in G.O.Ps.Nos.565 and 566 dated 12.3.1962 as
amended and indicated in Annexure V, with number of workers not exceeding 8
and electric machineries not exceeding 5 H.P.
viii) Garment industries, craft centers and assembly of electronic parts for
manufacture of radios, transistors, television sets, computer chips and such
other electronic industries with installations not exceeding 5 HP and the number
of employees not exceeding 25 numbers.
ix) Installation of Motor for pumping water, Air conditioning, Lifts, Solar Heaters,
Dish Antennas, etc.
x) Storage of domestic cooking gas cylinders subject to the conditions prescribed in
G.O.M.sNo.329 dated 24.2.1977 viz. the applicant should obtain necessary
clearance from the Director of Fire and Rescue Services and from the Dept. of
Explosives of the Govt. of India.
14
B. Permissible with the special sanction of the CMDA:
i) Hostels, and dormitories not exceeding 300 sq.m. in floor area.
ii) Working women hostels, old age homes
iii) Religious buildings, Welfare Institutions and Assembly Halls occupying floor
area not exceeding 300 sq.m.
iv) Govt./Semi Govt. Offices, Banks, Pay Offices, Post Office, Offices of Electricity
Board, Chennai City Corporation, Tamil Nadu Cooperative Milk Producers
Federation Limited, etc. occupying a floor area not exceeding 300 sq.m.
v) Public Utility Buildings like sewage pumping stations, water works, Fire
stations, Telephone exchanges.
vi) Swimming Pool attached to residential activity in a plot.
vii) Daily or weekly markets serving local needs.
viii) Transport depots, Bus Terminus and Railway Stations.
ix) Burning, Burial grounds, crematoria and cemeteries.
x) High schools and Higher Secondary Schools
xi) Restaurants not exceeding 300 sq.m. in floor area provided the width of the
abutting road is minimum 10 metres
xii) Clinics, Nursing Homes, Dispensaries and other Health facilities not exceeding
300 sq.m. in floor area provided the width of the abutting road is minimum 10
metres
xiii) Departmental stores with a floor area not exceeding 100 Sq.m provided the
width of the abutting road is minimum 10 metres
xiv) Fuel filling stations and service stations with installations not exceeding 5 HP
provided the width of the abutting road is minimum 10 metres
xv) Air-conditioned Cinema Theatres abutting min. 12 m wide road.
(2) All uses/activities not specifically mentioned under sub-regulations (1) above shall
be prohibited in this zone.
15. Mixed Residential use zone
(1) In this zone buildings or premises shall be permitted only for the following
purposes and accessory uses:
A. Normally permissible uses:
i) All activities permissible in Primary Residential use zone.
ii) Banks and Safe Deposit Vaults, Business Office and other Commercial or
Financial Institutions occupying floor area not exceeding 500 sq.m
iii) Hotels, Restaurants occupying a floor area not exceeding 500 sq.m.
iv) Hostels, Dormitories, Boarding and Lodging houses and Welfare Institutions
occupying a floor area not exceeding 500 sq.m.
v) Clinics, Hospitals, Dispensaries, Nursing Homes and other Health facilities
occupying a floor area not exceeding 500 sq.m.
15
vi) Establishments and shops retailing in vegetables, fruits, flowers, fish, meat and
such other daily necessities of the residents, including departmental stores
occupying floor area not exceeding 500 sq.m. or organized markets.
vii) Bakeries, Confectionaries, Laundries, tailoring, Goldsmith shops, hairdressing
saloons occupying floor area not exceeding 500 sq.m.
viii) Fuel filling stations, and automobile service stations with installation not
exceeding 30 HP.
ix) Industries listed by the Tamil Nadu Pollution Control Board as ‘Green’
Industries listed in Annexure-VI and subject to maximum installation of 30 HP.
x) Taxi stands and car parking including multilevel parking
xi) Automobile workshop with floor area not exceeding 300 sq.m and electrical
installations not exceeding 15 H.P.
B Permissible with special sanction of the CMDA:
i) All uses permissible under sub rule A (i) to (vii) above without restriction of floor
area.
ii) Religious buildings and welfare institutions occupying a floor area not exceeding
500 sq.m.
iii) Preview theatres and dubbing theatres.
iv) Colleges, higher educational, technical and research institutions.
v) Foreign Missions, Embassies and Consulates.
vi) Assembly Halls, Kalyana Mandapams and Cinema theatres, Multiplex complexes
along roads of width min. 12m.
(2) All uses/activities not specifically mentioned under sub-regulations (1) shall be
prohibited.
16. Commercial use zone
(1) In this zone, buildings or premises shall be permitted only for the following
purposes and accessory uses:
A Normally permissible uses:
i) All activities that is permissible in Primary Residential and Mixed Residential
Zones without restriction of floor area (except industries)
ii) All commercial and business uses including all shops, stores, markets, shopping
centers and uses connected with the display and retail sale of merchandise but
excluding explosives, obnoxious products and other materials likely to cause
health hazards and danger to lives.
iii) Fuel filling stations, automobile service stations and workshops with installation
not exceeding 50 HP.
iv) Industries listed out by the Tamil Nadu Pollution Control Board as “Green”
Industries listed in Annexure VI and as “Orange Industries” listed in Annexure
VII subject to a maximum installation of 50 HP.
v) Research, Experimental and Testing laboratories not involving danger of fire,
explosives or health hazards.
vi) Warehouses and other uses connected with storage of wholesale trade in
commodities not notified under the Specified Commodity Act, but excluding
storage of explosives or products which are either obnoxious or likely to cause
health hazards.
16
vii) Buildings for development of software and its associated computer technology
applications, IT Parks.
viii) Bio-informatics centres
B Permissible with special sanction of the CMDA:
i) Broadcasting, telecasting and telecommunication stations.
ii) Private helipads subject to clearance by Civil Aviation department, Directorate of
Fire and Rescue Services and police department.
iii) Manufacture of computer hardware
(2) All uses/activities not specifically mentioned under sub-regulations (1) shall be
prohibited.
17. Industrial use zone
(1) In this zone, buildings or premises shall be permitted only for the following
purposes and accessory uses:
A Normally permissible uses:
i) In approved layouts residential, commercial, institutional and other activities as
designated therein.
ii) All industries with machinery using electrical power not exceeding 200 H.P or
with employees not exceeding 100 in number but excluding industries of
obnoxious and hazardous nature by reasons of odour, effluent, dust, smoke,
gas, vibration or other wise likely to cause danger or nuisance to public health
or amenity.
iii) Residential buildings for security and other essential staff required to be
maintained in the premises.
B Permissible with the special sanction of the CMDA:
i) All use permissible in Residential, Mixed residential, commercial use zones
ii) Storage of petroleum timber and explosives and inflammable and dangerous
materials
iii) All industries (without restrictions of H.P or floor area or number of workers) not
producing noxious and dangerous effluents or where sufficient precautions to
the satisfaction of the Pollution Control Board have been taken to eliminate
noxious or dangerous effluents.
iv) Container terminals (at sites abutting or gaining access from minimum 18 metre
wide public road)
(2) All uses not specifically mentioned under sub-regulations (1) shall be prohibited in
this zone.
18. Special and Hazardous Industrial use zone
(1) In this zone buildings or premises shall be permitted only for the following uses and
accessory uses:
A Normally permissible uses:
i) All Industrial activities permissible in Industrial zone
ii) All special and hazardous industries (classified as 'Red' by the Tamil Nadu
Pollution Control Board) without restriction of Horse Power that are likely to be
dangerous to human life or health or amenity, but sufficient precaution to the
17
satisfaction of the TNPC Board have been taken to eliminate noxious or
dangerous effluents and to alleviate danger to human life or health or amenity
(Annexure-VIII).
iii) Uses involving storage, handling and other uses, incidental to such industries.
iv) Residential, commercial, Institutional and recreational uses incidental to the
uses listed above.
B Permissible with special sanction of the CMDA:
Uses permissible in Industrial use zone as may be decided by the Authority.
(2) All uses not specifically mentioned under sub-regulations (1) above shall be
prohibited.
19. Institutional use zone
(1) In this zone buildings or premises shall be permitted only for the following purposes
and accessory uses:
A. Normally permissible uses:
i) Educational institutions including colleges and institutions of higher education,
research, technical and training in nature.
ii) Govt. and quasi Govt. offices and institutions
iii) Professional and business offices
iv) Art galleries, Archives, Museums, Public Libraries, Social and Cultural
Institutions and Religious buildings.
v) Hospitals, Sanatoria, and other medical and public health institutions.
vi) Parks, Play fields, Swimming pools and other public and Semi public open
spaces.
vii) Broadcasting, telecasting, installations and Weather stations.
viii) Public utilities, municipal and community facilities.
ix) Nursery, Primary and Secondary Schools.
x) Social and Cultural Institutions including Sabhas.
xi) Residential and commercial spaces incidental to the activities permissible in this
use zone.
B. Permissible with special sanction of the CMDA:
i) Transport terminals, bus and railway stations, Airport, Harbour, and parking
lots including multilevel parking lots
ii) Cinema theatres and others entertainment centres and Kalyana mandapams.
iii) Clubs, community halls, Assembly halls, Auditoriums and Theatres
iv) Sports stadium, Recreation Complexes, Exhibition, Fares.
v) Burial Ground, Burning Ground, Cemeteries, crematoria
vi) Buildings for development of software and its associated computer technology
applications I.T.Parks
vii) Manufacture of computer hardware
viii) Bio- informatics centres.
ix) Container terminals at sites abutting and gaining access from public roads of
width minimum 18 metres
x) Foreign mission, Embassies, Consulates
(2) All uses not specifically mentioned under sub regulations (1) shall be prohibited.
18
20. Open Space and Recreational use zone
(1) In this zone buildings or premises shall be permitted for the following purposes and
accessory uses:
A Normally Permissible uses:
i) All public and semi public recreational uses and open spaces, parks and play
grounds, zoological and botanical gardens, nurseries, waterfront developments,
museums and memorials.
ii) Installations that may be necessary for the uses mentioned above.
B Permissible with special sanction of the CMDA:
i) Theme parks and amusement parks
ii) Open Air Theatre, Exhibitions, Circuses, Fairs and Festival grounds, public
utilities.
iii) Burial and burning grounds or crematoria.
iv) Incidental residential uses for essential staff required to be maintained in the
premises.
v) Incidental commercial uses
vi) Hotels and restaurants not exceeding 300 sq.m.
vii) Beach cottages each not exceeding 100 sq.m. in floor area and 7.5 m in height.
viii) Sports stadia and recreational complexes.
(2) All uses not specifically mentioned in sub regulations (1) shall be prohibited.
21. Urbanisable use zone
(1) In this use zone, buildings or premises shall be permitted for the following purposes
and accessory uses.
A Normally permissible uses:
All uses permissible in primary and mixed residential use zones
B Permissible with the special sanction of the CMDA:
(i) All uses permissible in commercial and institutional use zones
(ii) All industries with installations not exceeding 200 H.P and permissible in
industrial use zone
(2) All uses not specifically mentioned in sub regulations (1) shall be prohibited.
22. Non-Urban use zone
(1) In the Non-Urban use zone, buildings or premises shall be permitted for the
following purposes and accessory uses:
A Normally permissible uses:
i) All Agriculture uses
ii) Burning, Burial grounds, crematoria and cemeteries
iii) Salt pans and salt manufacturing.
iv) Brick, earthen tile or pottery manufacturing.
v) Stone crushing and quarrying.
vi) Sand, clay and gravel quarrying.
vii) Installation of electrical motors not exceeding 50 HP that may be required for the
uses mentioned above.
19
B Permissible with special sanction of the CMDA:
i) Incidental residential uses
(2) All uses not specifically mentioned in sub regulations (1) shall be prohibited.
23. Agricultural use zone:
(1) In the Agricultural use zone buildings or premises shall be normally permitted for
the following purpose and accessory uses:
A Normally permissible uses:
i) All Agricultural uses.
ii) Farm houses and buildings for agricultural activities.
iii) All the uses permissible in the residential use zone within the natham
boundaries (settlements)
iv) Dairy and cattle farms
v) Piggeries and poultry farms
vi) Forestry
vii) Storing and drying of fertilizers
viii) Installation of electric machinery of not exceeding 15 horse power may be
allowed for the uses mentioned above.
B Permissible with special sanction of the CMDA:
i) All uses normally permissible in the Primary Residential use zone with the
exception of residences.
ii) Sewage farms and garbage dumping sites.
iii) Mills for grinding, hulling, etc. of cereals, pulses, food grains and oil seeds
provided the site has proper access and installations do not exceed 50 H.P.
iv) Burning and Burial grounds, Crematoria and Cemeteries.
v) Brick kilns and clay tile manufacturing.
(2) All uses not specifically mentioned in sub regulations (1) shall be prohibited.
24. (1) Areas for buildings of special character:
(a) Multi- storeyed building (MSB) area:
i) Multi-storeyed buildings defined in this regulation no.2 are permissible only in
the areas specifically declared as MSB areas. Details of the areas declared as
Multi-storeyed building areas are given as Annexure IX
ii) In all other areas maximum height of the building shall not exceed 15.25 metres
provided water tanks, chimneys, Architectural features such as flag masts,
gopurams, minarets, steeples and other ornamental structures which are not
intended for human habitation may be permitted subject to a ceiling of 30.5
metres from ground level with special sanction of the Authority.
(b) Continuous building areas (CBA):
Buildings without side set back are permissible in a plot / site in continuous
building areas set apart in the Master Plan / DDP. However in an approved layout
area only in the plots classified for Continuous type of buildings it is permissible.
20
(c) Economically weaker section areas: (EWS)
Areas declared as slum by TNSCB are categorised as EWS areas for the purpose of
these regulations. In addition it includes the areas developed as EWS plot in the
TNHB neighbourhood schemes, S&S schemes, slum improvement schemes and
approved layouts.
(2) Ecologically sensitive areas:
(a) CRZ area:
The coastal stretches of seas, bays which are influenced by tidal action in the land
ward side up to 500 metres from the high tide line (HTL) and estuaries, creeks,
rivers and back waters which are influenced by tidal action in the land ward side up
to 100 metres from the high tide line (HTL) and the land between the low tide line
(LTL) and the high tide line (HTL) have been declared as coastal regulation zone
(CRZ). The catagorisation of CRZ within the Chennai Metropolitan Area (on the date
of preparation of this Master Plan) is given in Map No. MP-II/CMDA.9/2008.
Developments in this area shall be regulated with reference to the CRZ
classifications and regulations notified by the Government of India from time to time
under section 3 of the Environment (protection) Act, 1986. Details of the
Regulations (on the date of preparation of Master Plan) are given in Annexure X.
(b) Aquifer recharge area:
The areas, which have good aquifers and recharge potential have been declared as
aquifer recharge area. Description of the aquifer recharge area and the regulation
for developments therein are given in Annexure XI (refer Map No. MP-
II/CMDA.10/2008).
(c) Catchment area:
Redhills and Puzhal lakes are the main sources of water supply to the Chennai city.
In order to protect this water source from the negative impacts of the urban
developments contiguous areas in the catchments of these lakes has been declared
as 'Redhills catchments area'. The description of the catchments area and
regulations for development therein is given in the Annexure XII (refer Map No. MP-
II/CMDA.11/2008).
(3) Development prohibited area:
(a) Area around Indian Air Force station:
Lands to a depth of 100m around the boundary of the Indian Air Force station near
Tambaram has been zoned as areas prohibited for development as per the
Government of India Notification. Description of the said area is given in Map No.
MP-II/CMDA.12/2008.
(b) Pallikaranai Swamp area:
Considering its importance and drainage system in the area, the contiguous swamp
area in Pallikaranai has been declared for conservation as swamp area, prohibiting
development therein. Description of the Pallikaranai Swamp area prohibiting the
development is given in Map No. MP-II/CMDA.13/2008.
(4) Areas of special character:
(a) MRTS influence area:
In order to encourage Transit sensitive activities and to allow densifications in areas
around MRTS from Thirumayilai to Velachery have been declared as MRTS
21
influence area. Description of the area is given in Annexure XIV (refer Map No.MP-
II/CMDA.15/2008). FSI allowable in this area is maximum 2.00 for non-
multistoreyed residential developments with dwelling units each not exceeding 75
sq.metres in floor area.
(b) I.T Corridor:
Area to a depth of about 500 m on either side of the Rajiv Gandhi Salai (Old
Mamallapuram road) has been declared as I.T Corridor (described below) from
Kottivakkam and Perungudi village to CMA limits. Wherein irrespective of its zoning
in the Master Plan / Detailed Development Plan, I.T developments subject to the
regulations as specified in Annexure XIII are permissible (refer Map No. MP-
II/CMDA.14/2008)
I.T Corridor Zone - lands along the Rajiv Gandhi Salai (Old Mammallapuram Road)
-bounded by
North - Chennai City limit (Kottivakkam)
South - CMA limit (Semmancheri village)
East - Buckingham Canal
West - About 500 meters from Rajiv Gandhi Salai (Old
Mammallapuram Road) - as shown in the map.
(c) Area around Airport/Aerodrome:
The buildings/structures in the vicinity of aerodromes shall conform to the
regulations of the Civil Aviation Authority extracted and given in the Annexure XV.
However, latest rules, including amendments if any notified by the Directorate
General of the Civil Aviation shall be followed in all such cases of building
constructions in the vicinity of aerodromes. If the site is located within 20 kms.
from the aerodromes reference point, for constructions, which rise to 30 metres or
more in height, no objection certificate shall be obtained from the Directorate
General Civil Aviation. Areas within Chennai Metropolitan Area which fall in the
approach funnel, the transitional area and trough around runways are given in the
map annexed.
(5) Natural hazard prone areas:
Areas likely to have (i) moderate to very high damage risk zone of earth quakes, or
(ii) moderate to very high damage by cyclones, or (iii) significant flood flow or
inundation, or (iv) land slides proneness or potential, or (v) tsunami proneness, or
(vi) one or more of this hazards, have been declared as natural hazard prone areas.
Whole of Chennai Metropolitan Area falls in this natural hazard prone areas
classification. Structural design and aspects of the building constructions in the
Chennai City, Municipalities, and Panchayats shall also take into account of the
special provisions contained in the Building Rules under the Chennai City
Municipal Corporation Act, Building Rules under the T.N. District Municipalities Act
and Building Rules under T.N. Panchayats Act respectively relating the regulations
for natural hazard prone areas.
(6) Green Belt along Poonamallee Bye pass and Redhills Bye pass roads.
As per National Highways standards, green belts on either side to a depth of 15
metres along Poonamallee Bye pass Road and Red hills Bye pass road have been
reserved. In this green belt area forming part of plots/sites, no development except
gate pillars and watchman booth is permissible.
22
25. Planning Parameters:
The extent of the site, plot coverage, FSI, set back etc. for the developments shall be
regulated according to the tables below:
Table (1) Ordinary Residential Buildings and other small developments
• Ordinary residential / predominantly residential buildings, Clinics, dispensaries,
nursing homes with floor area not exceeding 300 sq.m. and G+1 floor in height.
• Working women hostels / old age homes with floor area not exceeding 500 sq.m.
and G+1 floor in height.
• Corporate / Institution Guesthouses with floor area not exceeding 300 sq.m. and
G+1 floor in height.
• Cottage industries (with number of workers not exceeding 8 and electric
machineries not exceeding 5 H.P.) with floor area not exceeding 300 sq.m. and G+1
floor in height.
• Nursery schools, primary schools with floor area not exceeding 300 sq.m.
• Reading rooms, libraries, Post office, EB Office, telegraphic office, Local body
maintenance offices with floor area not exceeding 300 sq.m.
Sl.No Description
Continuous
Building
Area
anywhere
within CMA
Rest of CMA except CBA
Residential in
Economically Weaker
Section areas
Chennai
City
in other
areas
1 2 3 4 5a 5b
A Minimum
Plot extent
50
sq.m. 80 sq.m 20 sq.m. 40sq.m.
B
Minimum
Plot width/
frontage
4.5m 6m 4m 4m
C Minimum
Road width - 6m - -
D
Maximum
Height
G+1 or Stilt
+2 floors
subject to a
max. of 9m
G+1 or Stilt +2 floors subject to a
max. of 9m
G+1 subject to a
max. of 7 m
E Maximum
FSI 1.5 1.5 1.5 1.5
F Maximum
Plot coverage 75% 70% 75% 75%
G Minimum
Setbacks
Where Street Alignment/new road is prescribed in these
regulations, it shall be from that street alignment/ new road line.
In the case of others, it shall be from the property boundary.
(i) Front
Set back 1.5m
Abutting Road
Width Set back
1m 1m
Up to 10m 1.5m
Above 10m, up to
15.25m 3.0m
Above 15.25m,
up to 30.5m 4.5m
Above 30.5m 6.0m
23
(ii) Side Set
back Nil
Plot Width Side set back
Nil Nil
Up to 6m 1m on one side
Above 6m, up to
9m
1.5m on one
side
Above 9m 1.5m on either
side
(iii) Rear Set
back Nil
1.5m 1m 1m
In Rear set back, structures like lavatory, lumber room,
garage etc. not intended for human habitation and servant
quarters are permissible provided it doesn't occupy more
than one third of the plot width, 6m from rear boundary
and 4 metres in height from ground level.
H Other structures permissible in the minimum prescribed Front set back, Side set
back, and Rear set back are as given in the regulation No 11.
I Parking spaces shall be provided within the site conforming to the regulations
given in the Annexure XVI.
J The minimum width of corridor shall be as given in the Annexure XVII.
K Rainwater harvesting provisions as prescribed in the Annexure XIX shall be
provided.
Note: (i) In CBA, there shall be atleast 1m wide internal passage from rear to front in
Ground floor, directly accessible to road.
♣(ii) In cases of Residential or predominantly residential developments, -
(a) where dwelling units for Economically Weaker Sections do not exceed 30
sq.m in floor area each, 50% of normally permissible FSI is additionally
allowable over and above the normally permissible FSI; and
(b) where dwelling units for Low Income Group do not exceed 50 sq.m in floor
area each, 30% of normally permissible FSI is additionally allowable over and
above the normally permissible FSI;
Provided that the developer or promoter or owner shall not sell these dwellings for
other than the said purposes and no conversion or amalgamation shall be
permissible in these cases of lower income group dwellings. ♣
Table (2) Ordinary Commercial Buildings and other small developments
Ordinary commercial / predominantly commercial buildings including shops,
private offices, banks, restaurants, fuel filling stations with or without service stations not
exceeding 5 H.P, Departmental stores, clinical labs, Schools of Commerce, with floor area
less than 300 sq.m. and up to Ground +one floor.
Sl.No Description
Continuous Building
Area anywhere within
CMA
Chennai city, Municipal &
Town Panchayat area
excluding the areas
mentioned in col. 3
Rest of CMA
1 2 3 4 5
A Minimum Plot
extent 50 sq.m 80 sq.m 80 sq.m
♣ Approved in G.O. Ms No.103, H&UD Dept., dt. 29.04.2010 and published in TNGG on 26.05.2010
24
B Minimum Plot
frontage/ width 4m 6m 6m
C Minimum road
width 4.8m 7.2m 7.2m
D Maximum Height G+1 floors or stilt + 2 floors or 9.0m in height above Ground level
E Maximum FSI 1.5 1.5 1.5
F Maximum Plot
coverage 75% 70% 65%
G Minimum
Setbacks
Where Street Alignment/new road is prescribed in these
regulations, it shall be from that street alignment/ new road line.
In the case of others, it shall be from the property boundary.
(i) Front Setback 1.5m
Abutting road width Front Setback
Up to 10m 1.5m
Above 10m up to
15.25m 3.0m
Above 15.25m up
to 30.5m 4.5m
Above 30.5m 6m
(ii) Side Setback Nil
Plot Width Side Setback
Up to 4.5m Nil
Above 4.5m, up to
6m 1m on one side
Above 6m up to 9m 1.5m on one side
Above 9m 1.5m on either
side
(iii) Rear Setback Nil 1.5m 1.5m
H Structures permissible in the minimum prescribed Front Setback, Side setback,
and Rear Setback are in the regulation No. 11
I Parking spaces shall be provided within the site conforming to the regulations
given in the Annexure XVI.
J The minimum width of corridor shall be as given in the Annexure XVII.
K Rainwater harvesting provisions as prescribed in the Annexure XIX shall be
provided.
Note: (i) In cases of fuel filling stations, the buildings proposed within the premises shall
not exceed single storeyed and clearance of the Explosives department shall be
furnished for the development.
(ii) In CBA, there shall be atleast 1m wide internal passage from rear to front in
Ground floor, directly accessible to road.
25
Table (3) Cottage industries, Green industries and Orange industries upto 30 H.P
Sl.No. Description
Continuous
Building Area
any where
within CMA
Chennai city, Municipal
& Town Panchayat area
excluding the areas
mentioned in col. 3
Rest of
CMA
1 2 3 4 5
A Minimum Plot
extent 150 sq.m 220 sq.m 330 sq.m
B Minimum Plot
frontage/ width 6m 9m 12m
C Minimum road
width 7.2 m
D Maximum
Height
One and half times the width of the abutting road
provided that the height may be exceeded to the extent of
1 metre for every 30 centimeters by which the building is
set back from the street or 15.25 metres.
E Maximum FSI 1.00 1.25 1.5
F Maximum Plot
coverage 75% 75% 75%
G Minimum
Setbacks
Where Street Alignment/new road is prescribed in these
regulations, it shall be from that street alignment/new
road line. In the case of others, it shall be from the
property boundary.
(i) Front Setback 1.5m
Abutting road width
Front
Setback
Up to 10m 1.5m
Above 10m up to 15.25m 3.0m
Above 15.25m up to 30.5m 4.5m
Above 30.5m 6m
(ii) Side Setback Nil 1.5m on either side
(iii) Rear Setback Nil 1.5m
H
a) Structures permissible in the minimum prescribed Front set back, Side
setback and Rear set back are given in the regulations No. 11
b) In addition, incidental structures such as Gate pillars, servant room,
watch man booth, cycle stand and toilets with height not exceeding 4m are
permissible in these minimum prescribed setback spaces.
I Parking spaces shall be provided within the site conforming to the
regulations given in the Annexure XVI.
J Rainwater harvesting provisions as prescribed in the Annexure XIX shall be
provided.
Note: In CBA, there shall be atleast 1m wide internal passage from rear to front in Ground
floor, directly accessible to road.
26
Table (4) Green industries, and Orange industries (other than Special and Hazardous
industries) up to 200 HP permissible in industrial use zone
Sl.No. Description
Continuous
Building Area
anywhere
within CMA
Chennai city,
Municipal & Town
Panchayat area
excluding the areas
mentioned in col. 3
Rest of CMA
1 2 3 4 5
A Minimum Plot
extent 220sq.m 330sq.m. 440sq.m
B
Minimum Plot
frontage/
width
9m 12m. 12m.
C Minimum
road width 7.2m.
D Maximum
Height
One and half times the width of the abutting road provided that
the height may be exceeded to the extent of 1 metre for every 30
centimeters by which the building is set back from the street or
15.25metres.
E Maximum FSI
1.0 1.25 1.25*
(if the road width is
more than 9.0m, FSI
upto 1.50 can be
permitted)
.
F Maximum
Plot coverage 75% 75% 75%
G Minimum
Setbacks
Where Street Alignment/new road is prescribed in these
regulations, it shall be from that street alignment/new road line.
In the case of others, it shall be from the property boundary.
(i) Front Setback 6m
(ii) Side Setback Nil 2m on either side
(iii) Rear Setback Nil Nil
H
a) Structures permissible in the minimum prescribed Front set back, Side
setback and Rear set back are given in the regulations No. 11.
b) In additions, incidental structures such as Gate pillars, servant room, watch
man booth, cycle stand and toilets with height not exceeding 4m are
permissible in these minimum prescribed setback spaces.
I Parking spaces shall be provided within the site conforming to the regulations
given in the Annexure XVI.
J Rainwater harvesting provisions as prescribed in the Annexure XIX shall be
provided.
Note: In CBA, there shall be atleast 1m wide internal passage from rear to front in
Ground floor, directly accessible to road .
27
Table (5) Industries exceeding 200 H.P. (other than the industries listed under
Special and Hazardous Industries)
Sl.No. Description
Continuous
Building Area
anywhere
within CMA
Chennai city, Municipal
& Town Pancahyat area
excluding the areas
mentioned in col. 3
Rest of
CMA
1 2 3 4 5
A Minimum Plot
extent Not applicable 2000 sq.m. 1500 sq.m.
B
Minimum Plot
frontage/
width
Not applicable
30m 25m
C Minimum
road width Not applicable 9 m
D Maximum
Height Not applicable
One and half times the width of the
abutting road provided that the height
may be exceeded to the extent of 1 metre
for every 30 centimeters by which the
building is set back from the street or
15.25 metres.
E Maximum FSI Not applicable 1.25 1.25
F Maximum
Plot coverage Not applicable 75% 75%
G Minimum
Setbacks
Not applicable
Where Street Alignment/new road is
prescribed in these regulations, it shall be
from that street alignment/new road line.
In the case of others, it shall be from the
property boundary.
(i) Front Setback 8m
(ii) Side Setback 3.5m on either side
(iii) Rear Setback 3.5m
H
a) Structures permissible in the minimum prescribed Front set back, Side
setback and Rear set back are given in the regulations No. 11
b) In additions, incidental structures such as Gate pillars, servant room,
watch man booth, cycle and two wheeler stands and toilets with height not
exceeding 4m are permissible in these minimum prescribed setback
spaces.
Provided total length of such incidental structures in the setback spaces
shall not exceed 50% in length of the longer side.
I Parking spaces shall be provided within the site conforming to the regulations
given in the Annexure XVI.
J Rainwater harvesting provisions as prescribed in the Annexure XIX shall be
provided.
28
Table (6) Special and Hazardous Industries (Red Industries)
Sl.No. Description
Continuous Building
Area anywhere within
CMA & Chennai city
Municipal & Town
Panchayat area
excluding the
areas mentioned in
col. 3
Rest of CMA
1 2 3 4 5
A Minimum Plot
extent Not applicable 1500 sq.m 1000sq.m
B
Minimum Plot
frontage/
width
Not applicable 25m 20m
C Minimum
road width Not applicable 9 m
D Maximum
Height Not applicable
One and half times the width of the abutting
road provided that the height may be
exceeded to the extent of 1 metre for every 30
centimeters by which the building is set back
from the street or 15.25 metres.
E Maximum FSI -do- 1.0 1.25
F Maximum
Plot coverage -do- 75% 75%
G Minimum
Setbacks -do-
Where Street Alignment/new road is
prescribed in these regulations, it shall be
from that street alignment/narrow line. In
the case of others, it shall be from the
property boundary.
(i) Front Setback -do- 8m
(ii) Side Setback -do- 6m
(iii) Rear Setback -do- 6m
H
a) Structures permissible in the minimum prescribed Front set back, Side
setback and Rear set back are given in the regulations No. 11.
b) In additions, incidental structures such as Gate pillars, servant room, watch
man booth, cycle stand and toilets with height not exceeding 4m are
permissible in these minimum prescribed setback spaces.
I Parking spaces shall be provided within the site conforming to the regulations
given in the Annexure XVI.
J Rainwater harvesting provisions as prescribed in the Annexure XIX shall be
provided.
29
Table (7) Institutional buildings
Including nursery schools, Primary schools and religious buildings with floor area
exceeding 300 sq.m. Secondary schools, Colleges, Higher Educational, Technical &
Research Institutions, Students hostels & Dormitories, Research Institutions,
Broadcasting, Telecasting & Telecommunication centers, Government & Quasi Government
offices, and Institutions, Government archives, Museums, Art galleries and Public libraries,
foreign missions, Consulates and embassies.
Sl.No. Description
Continuous
Building Area
anywhere within
CMA
Chennai city,
Municipal & Town
Pancahyat area
excluding the areas
mentioned in col. 3
Rest of CMA
1 2 3 4 5
A Minimum Plot
extent 500 sq.m 1000 sq.m 1000sq.m
B Minimum Plot
frontage/ width 20m 30m 30m
C Minimum road
width 7.20m
Upto 2 hectares in plot extent - 12m
Exceeding 2 hectares in plot extent - 18m
provided that it shall be min. 7.2m for
schools upto higher secondary level and
industrial training institutes.
Maximum
Height
One and half times the width of the abutting road provided
that the height may be exceeded to the extent of 1 metre for
every 30 centimeters by which the building is set back from
the street or 15.25 metres.
D Maximum FSI 1.5 1.5 1.5
E Maximum Plot
coverage 50% 40% 33%
F Minimum
Setbacks
Where Street Alignment/new road is prescribed in these
regulations, it shall be from that street
alignment/narrow line. In the case of others, it shall be
from the property boundary.
(i) Front Setback 6m 6m 6m
(ii) Side Setback Nil 6m 6m For schools - 2m
(iii) Rear Setback Nil 6m 6m For schools - 2m
G
a) Structures permissible in the minimum prescribed Front set back, Side
setback and Rear set back are given in the regulations No. 11.
b) In addition, Gate pillars, gopurams, and incidental structures (with
height not exceeding 4m) such as servant room, cloak room, and
watch man booth, cycle stand, Kitchen and toilets are permissible in
these minimum prescribed setback spaces.
H Parking spaces shall be provided within the site conforming to the
regulations given in the Annexure XVI.
I The minimum width of corridor shall be as given in the Annexure XVII.
J Rainwater harvesting provisions as prescribed in the Annexure XIX shall
be provided.
K Special regulations for physically disabled stated in the Annexure XXII
shall be adhered to.
L Solar energy capture provisions as prescribed in the Annexure XXIII shall
be provided where applicable.
30
M
The applicant shall deposit a sum at the rate of Rs. 50 per square metre of
floor area as a refundable non-interest earning security and earnest deposit.
The deposit shall be refunded on completion of development as per the
approved plan as certified by Chennai Metropolitan Development Authority; if
not, it would be forfeited.
Note: (i) In CBA, there shall be atleast 1m wide internal passage from rear to front in
Ground floor, directly accessible to road.
(ii) In cases of Government and Quasi-Government hospital buildings an additional
FSI of 0.25 is allowable over and above the normally permissible FSI.
Table (8) Religious buildings with floor area less than 300 sq.m. and height not
exceeding G+1 floors
Sl.No. Description
Continuous
Building Area
anywhere within
CMA
Chennai city, Municipal &
Town Panchayat area
excluding the areas mentioned
in col. 3
Rest of
CMA
1 2 3 4 5
A Minimum Plot
extent 60 sq.m. 90 sq.m. 90 sq.m.
B Minimum Plot
width/ frontage 4.5m 6m 6m
C Minimum road
width 7.2 m
D Maximum
Height
One and half times the width of the abutting road
provided that the height may be exceeded to the extent of
1 metre for every 30 centimeters by which the building is
set back from the street or 15.25 metres.
E Maximum FSI 0.75 0.75 0.75
F Maximum Plot
coverage 75% 75% 75%
G Minimum
Setbacks
Where Street Alignment/new road is prescribed in these
regulations, it shall be from that street alignment/ new road
line. In the case of others, it shall be from the property
boundary.
(i) Front Set back 1.5m
Abutting Road width Setback
Up to 10m 1.5m
Above 10m, up to
15.25m 3.0m
Above 15.25m, up
to 30.5m 4.5m
Above 30.5m 6.0m
(ii) Side Set back Nil 2m
(iii)
Rear Set
back
Nil
2m
In addition, incidental structures such as
gopuram, gate pillars, servant room,
watch man booth, cycle stand, kitchen
and toilets with height not exceeding 4m
are permissible in these minimum
prescribed setback spaces.
H
Other structures permissible in the minimum prescribed Front set back, Side
set back, and Rear set back are as given in the regulation No. 11.
I Parking spaces shall be provided within the site conforming to the regulations
given in the Annexure XVI.
J The minimum width of corridor shall be as given in the Annexure XVII.
K Rainwater harvesting provisions as prescribed in the Annexure XIX shall be
provided.
Note: In CBA, there shall be atleast 1m wide internal passage from rear to front in
Ground floor, directly accessible to road
31
Table (9) Transport Terminals such as Bus Terminals, Bus stands, Railway
stations, Truck terminals, container terminals:
Sl.No. Description
Continuous
Building Area
anywhere within
CMA
Chennai city,
Municipal & Town
Panchayat area
excluding the areas
mentioned in col. 3
Rest of CMA
1 2 3 4 5
A Minimum Plot
extent 500 sq.m 1000 sq.m 1000sq.m
B Minimum Plot
frontage/ width 12m 20m 20m
C Minimum road
width
10m except for
Container terminals where it shall be 18m
Maximum Height
One and half times the width of the abutting road provided
that the height may be exceeded to the extent of 1 metre
for every 30 centimeters by which the building is set back
from the street or 15.25metres.
D Maximum FSI 1.00 1.00 1.00
E Maximum Plot
coverage 75% 75% 75%
F Minimum
Setbacks
Where Street Alignment/new road is prescribed in these
regulations, it shall be from that street alignment/narrow
line. In the case of others, it shall be from the property
boundary.
(i) Front Setback 6m 6m 6m
(ii) Side Setback 2m on either
side 6m on either side 6m on
either side
(iii) Rear Setback 2m 6m 6m
G
a) Structures permissible in the minimum prescribed Front set back, Side
setback and Rear set back are given in the regulations No. 11.
b) In additions, incidental structures such as gate pillars, servant room,
watch man booth, cycle stand, kitchen and toilets with height not
exceeding 4m are permissible in these minimum prescribed setback
spaces.
H Parking: 10% of the extent of the site shall be reserved for parking in the
part of site carved out in a regular shape with frontage abutting the road.
I Rainwater harvesting provisions as prescribed in the Annexure XIX shall be
provided.
J Special regulations for physically disabled stated in the Annexure XXII shall
be adhered to.
Note: In CBA, there shall be atleast 1m wide internal passage from rear to front in
Ground floor, directly accessible to road.
32
26. Regulation for Special Buildings:
(1) “ Special Buildings” means
a) a residential or commercial buildings with more than 2 floors; or
b) a residential building with more than six dwelling units; or
c) a commercial building exceeding a floor area of 300 square metres:
Provided that any construction in the second floor with prior permission as an
addition to an existing ground and first storeyed authorised ordinary residential
building which is three years old shall not be construed as a “Special Building”
(2) (a) The minimum width of the public road on which the site abuts or gains access
shall be 10 mtrs.
Provided that if the extent of the site is more than 1100 sq.m. a special building for
residential use may be permitted on a site abutting or gaining access from 9m. wide
public road.
Provided further that special building for residential use may be permitted with
limitation on maximum number of dwellings and / maximum height of the building
on a site abutting or gaining access from 9 m wide public road subject to
compliance of the planning parameters stated in the Tables under sub rule (3)
below.
The minimum width stated above shall be the existing width of the road and not the
street alignment prescribed.
Explanation:
(i) Road width means the road space as defined in DR no. 2 (35). The qualifying road
width for permitting special building shall be available atleast for a stretch of 250m
along the length of the road abutting the site and the stretch from a junction can be
straight or a curve or zigzag or combination of the above.
To cite examples:
a) If the road over its general length is of 10 metres width, but because of some
kinks in front of the site one end is 9.8 metres and the other end is 10.2 metres
is acceptable.
b) If the general road is of width less than 10 metres width, but only widens
opposite to or nearer to the site is more than 10 metres, is not acceptable.
c) If the road is generally of 10 metres width upto a considerable length on one
side, but discontinues and narrows into a road of smaller width on the other
side of the site in question and the plot owner is willing to leave enough space
for continuity of 10 metres road in front of his site, this will have to be checked
and decided on case-by-case.
d) If the general road width is less than 10 metres and the site owner merely agrees
to leave enough space to have 10 metres in front of his site only, this is not
acceptable.
(ii) Road width measurements for the above purpose shall be of the road as designed
and laid and the existence of unauthorized encroachments, for which no patta has
been given, will not normally affect adversely provided the shortage in width in the
min. stretch stated above does not exceed 10% of the min. prescribed width.
However permissibility or otherwise (in exceptional cases) in such specific situations
will be decided case-by-case.
33
(b) If the site does not directly abut a public road but gains access through a private
exclusive passage or through a part of the plot which can be treated as a
passage from a public road of minimum width as prescribed above, the
minimum width of such passage shall be as follows:
Sl.No. Description Minimum width
(1)
When it is intended to serve six dwellings or up to 600 square
metres of commercial building and the length of the passage
does not exceed 80 metres.
3.6 metres
(2)
When it is intended to serve upto 8 dwellings or upto 2,400
square metres of commercial building and the length of the
passage does not exceed 100 metres.
4.8 metres
(3)
When it is intended to serve not more than 10 dwellings or
upto 3000 square metres of commercial building and the
length of passage does not exceed 120 metres.
7.2 metres
(4)
When it is intended to serve not more than 20 dwellings or
up to 6000 square metres of commercial building and the
length of passage does not exceed 240 metres.
9.0 metres
(5) When it is intended to serve more than 20 dwellings or more
than 6000 square metres of commercial building. 10.0metres
(3) The extent of site, FSI, Set back etc. for Residential / Predominantly residential Special
buildings shall be regulated according to the tables below:
Table A
Description Continuous Building Area anywhere within CMA
Max. no. of
dwelling units 8 12 -
Min. Road
width 9m 9m 10m
Min. Plot
Extent 50 sq.m. 80 sq.m. 80 sq.m.
Min. Plot
Frontage 4.5m
Max. Height G+1 or Stilt+2 subject
to a max. of 9m
G+2 or Stilt+3 subject
to a max. of 12m
G+3 or Stilt+4 subject
to a max. of 15.25m
Max. FSI 1.5
Minimum
Setbacks
Where Street Alignment/new road is prescribed in these regulations, it
shall be from that street alignment/ new road line.
In case of others, it shall be from the property boundary.
Min. FSB
Abutting Road width Set back
15.25m and below 3.5m
Above 15.25m & up to 30.5m 4.5m
Above 30.5m 6m
Min. SSB on
either side Nil
Min. RSB Nil
34
Note: (i) For EWS housing development, the minimum plot extent shall be 20 sq.m within
city and 40 sq.m. in the rest of CMA, frontage shall be minimum 4 m.
(ii) In CBA, there shall be atleast 1m wide internal passage from rear to front in
Ground floor, directly accessible to road
♣ (iii) In cases of Residential or predominantly residential developments, -
(a) where dwelling units for Economically Weaker Sections do not exceed 30
sq.m in floor area each, 50% of normally permissible FSI is additionally
allowable over and above the normally permissible FSI; and
(b) where dwelling units for Low Income Group do not exceed 50 sq.m in floor
area each, 30% of normally permissible FSI is additionally allowable over and
above the normally permissible FSI;
Provided that the developer or promoter or owner shall not sell these dwellings for
other than the said purposes and no conversion or amalgamation shall be
permissible in these cases of lower income group dwellings. ♣
Table B
Description Other areas in Chennai City, and the rest of CMA
Max. no. of
dwelling units 6 8 12
Min. Road width 9m 9m 9m
Min. Plot Extent 200 sq.m. 300
sq.m. 450 sq.m. 450
sq.m. 660 sq.m.
Min. Plot
Frontage 9m 9m 12m 15m 12m 15m 18m
Max. Height
G+2 or
Stilt+3
subject to
a max. of
12m
G+1 or
Stilt+2
subject
to a
max. of
9m
G+2 or
Stilt+3
subject
to a
max. of
12m
G+3 or
Stilt+4
subject
to a max.
of
15.25m
G+1 or
Stilt+2
subject
to a
max. of
9m
G+2 or
Stilt+3
subject
to a
max. of
12m
G+3 or
Stilt+4
subject
to a
max. of
15.25m
Max. FSI 1.5 1.5 1.5
Minimum
Setbacks
Where Street Alignment/new road is prescribed in these regulations, it shall
be from that street alignment/ new road line.
In case of others, it shall be from the property boundary.
Min. FSB
Abutting Road width Set back
15.25m and below 3.5m
Above 15.25m & up to 30.5m 4.5m
Above 30.5m 6m
Min. SSB on
either side 2.5m 1.5m 2.5m 4.0m * 1.5m 2.5m 4.0m *
Min. RSB 2.5m 1.5m 2.5m 4.0m ** 1.5m 2.5m 4.0m **
Note: * (i) In cases where the min. required SSB is more than 3.5m option can be had to
leave the min. 3.5m on one side and the remainder of the total of both the min.
required SSBs on the other side.
♣ Approved in G.O. Ms No.103, H&UD Dept., dt. 29.04.2010 and published in TNGG on 26.05.2010
35
** (ii) Similarly when minimum required RSB is more than 3.5m option can also be
had to leave the min required 3.5m on the rear and the remainder of the min. in
the front.
♣ (iii) In cases of Residential or predominantly residential developments, -
(a) where dwelling units for Economically Weaker Sections do not exceed 30
sq.m in floor area each, 50% of normally permissible FSI is additionally
allowable over and above the normally permissible FSI; and
(b) where dwelling units for Low Income Group do not exceed 50 sq.m in floor
area each, 30% of normally permissible FSI is additionally allowable over and
above the normally permissible FSI;
Provided that the developer or promoter or owner shall not sell these dwellings for
other than the said purposes and no conversion or amalgamation shall be
permissible in these cases of lower income group dwellings. ♣
Table C
Description Other areas in Chennai City, and the rest of CMA
Max. no. of
dwelling units
-
Min. Road
width 9m 10m
Min. Plot Extent 1100 sq.m. 300 sq.m. 450 sq.m.
Min. Plot
Frontage 15m 9m 12m 15m
Max. Height
G+1 or
Stilt+2
subject to
a max. of
9m
G+2 or
Stilt+3
subject to
a max. of
12m
G+3 or
Stilt+4
subject to a
max. of
15.25m
G+1 or
Stilt+2
subject to a
max. of
9m
G+2 or
Stilt+3
subject to a
max. of
12m
G+3 or
Stilt+4
subject to a
max. of
15.25m
Max. FSI 1.5
Minimum
Setbacks
Where Street Alignment/new road is prescribed in these regulations, it shall be
from that street alignment/ new road line.
In case of others, it shall be from the property boundary.
Min. FSB
Abutting Road width Set back
15.25m and below 3.5m
Above 15.25m & up to 30.5m 4.5m
Above 30.5m 6m
Min. SSB on
either side 1.5m 3.5m 4.0m * 1.5m 3.5m 4.0m *
Min. RSB 1.5m 3.5m 4.0m ** 1.5m 3.5m 4.0m **
Note: * (i) In cases where the min. required SSB is more than 3.5m option can be had to
leave the min. 3.5m on one side and the remainder of the total of both the min.
required SSBs on the other side.
** (ii) Similarly when minimum required RSB is more than 3.5m option can also be
had to leave the min required 3.5m on the rear and the remainder of the min. in
the front.
♣ Approved in G.O. Ms No.103, H&UD Dept., dt. 29.04.2010 and published in TNGG on 26.05.2010
36
♣ (iii) In cases of Residential or predominantly residential developments, -
(a) where dwelling units for Economically Weaker Sections do not exceed 30
sq.m in floor area each, 50% of normally permissible FSI is additionally
allowable over and above the normally permissible FSI; and
(b) where dwelling units for Low Income Group do not exceed 50