Legal Metrology (General) Rules, 2011 with amendments
Rules made under Legal Metrology Act 2009
- Made under: Legal Metrology Act 2009
This text is shown as one document.
Full text
,, - ',, J-· ~'
318 ·THE GAZETTE OF'!NDIA: EXTRAORDINARY [PART II-SEC. 3(i))
MINISTRY OF CONSUMER AFFAIRS, FOOD AND
PUBLIC DJSTRIBUTION
(DEPARTMENT OF CONSUMER AFFAIRS)
NOilFICATION
New:Delhl; the. 7th February 2011
G.S.R. ll(E).- In exercise of the powers
conferred by sub-section {1) read with Clauses (c),
(f), (h), (i) and_(~) of sub-section (2) ofsectlon 52 of
The Legal Metrology Act 2009, (l.of 2010), the Central
Government here~y,makes,thefollowing rules, namely
CHAPTER I
. PRELIMINARY
1. Short title and•commencement
(1) These rules may be called the Legal
Metrology (General) Rules, 2011.
(2) They shall mme into force on the 1• day of
April, 2011.
2. Definitions
In these rules, unless the context otherwise
requires,-
(a) "Act" means the Legal Metrology Act, 2009
(1 of 2010);
(b) "Schedule" means a Schedule appended to
these rules;
(c) "Section" means a Section of the Act;
(d) words and expressions used in these rules
and not defined but defined In the Act shall
. have the meanings respectively assigned to
them In the Act.
CHAPTERll
SPEOACATIONS OF STANDARDS OF WEIGHTS AND
MEASURES
3. Reference standards
(1) Every reference standard weight shall
conform, as regards denomination, material used in
construction, and design, to the specifications laid down
In Part I of First Schedule.
(2) The ~axlmum permissible error In respect
of any reference standard weight, on verification or
re-verification after adjustment, shall be such as is
specified in Part I of First Schedule.
(3) Every reference standard metre bar shall
conform, as regards material used in construction, and
design, to the specifications laid down in Part II of First
Schedule. ·
( 4) The maximum permissible error in respect
of any reference standard metre bar, on verification or
re-verification, shall be such as Is specified in Part II of
First Schedule.
4. Secondary standards
(1) Every secondary standard weight shall
conform, as regards denomination, material used In
construction, and design, to the specifications laid down
In Part I of Second Schedule.
(2) The maximum permissible error in respect
of any secondary standard weight, on verification or
re-verification after adjustment, shall be such as Is
specified In Part I of Second Schedule .
(3) Every secondary standard metre bar shall
conform, as regards material used in construction, and
design, to the specifications laid down in Part II of
Second Schedule.
(4) The maximum permissible error in respect
of any secondary standard metre bar, on verification
or re-verification, shall be such as Is specified in Part II
of Second Schedule.
(5) Every secondary standard capacity measure
shall conform, as regards denomination, material used
in construction, and design, to the specifications laid
down In Part Ill of Second Schedule.
(6) The maximum permissible error in respect
of any secondary standard capacity measure, on
verification or re-verification after adjustment, shall
be such as Is specified in Part Ill of Second Schedule.
5. Working standards
(1) Every working standard weight shall conform,
as regards denomination, material used in construction,
and design, to the specifications laid down in Part I of
Third Schedule.
(2) The maximum permissible error in respect
of any working standard weight, on verification or re
verification after adjustment, shall be such as Is
specified In Part I of Third Schedule.
(3) Every working standard metre bar shall
conform, as regards material used in construction, and
design, to the specifications laid down in Part II of Third
Schedule.
(4) The maximum permissible error in respect
of any working standard metre bar,.on verification or
re-verification, shall be such as Is specified in Part II of
Third Schedule.
(5) Every working standard capadty measure
shall conform, as regards denomination, material used ·
in construction, and design, to the specifications laid
down In Part Ill of Third Schedule.
- -----.,-----,--c-----:---------------:----
(6) The maximum permissible error In respect
of any working standard capacity measure, on
verification or re-verification after adjustment, shall
be such as is specified in Part III ofThlrd Schedule.
6. Power to specify any other reference,
secondary or working standard
(1) Any other reference standard, or secondary
standard, or working standard shall conform as regards ·
the denomination, material used in construction, and
design, to such specifications as the Central
Government may, from time to time, by notification,
specify.
(2) The maximum permissible error In relation
to such other reference standard, or secondary
standard, or working standard shall be such as the
Central Government may, from time to time, by
notification, specify and different maximum permissible
errors may be specified in relation to different types
of reference standards, or secondary standards, or
working standards.
CHAPTER ill
SPECIACATIONS OF STANDARD EQUIPMENT
7. Reference standard balances
(1) A set of reference standard balances shall
be maintained at every place where the reference
standard weights are kept for the purpose of
verification of secondary standards.
(2) The number, types and specifications of such
balances shall be as are specified in Part I of Fourth
Schedule.
(3) Every reference standard balance shall be
verified at least once In six months and shall be
adjusted, if necessary, to make it correct within the
limits of sensitivity and other metrological qualities as
are specified in Part I of Fourth Schedule.
s. Secondary standard balances
( 1) A set of secondary standard balances shall
be maintained at every place where secondary
standard weigbts are kept for the purpose of
verification of working standards.
(2) The number, types and specifications of such
balances shi!_ll be as are specified in Part II of Fourth
Schedule.
(3) Every secondary standard balance shall be
verified at least once In one year and shall be adjusted,
if necessary, to make It correct within the limits of
sensitivity and other metrological qualities as are
specified in Part II of Fourth Schedule.
9. Working standard balances
(1) Asetofworklng standard balances shall be
maintained at every place where working standard
. -~·---~---·· --- ----:--·" , ____________________________ --- __ ._.,_,_. __ _
319
weights are kept for the purpose of verification of
weights Intended to be used for transaction or
protection.
(2) The number, types and specifications of such
balances shall be as are laid down In Part Ill of Fourth
Schedule.
(3) Every working standard balance shall be
verified at least once in a year and shall be adjusted,
if necessary, to make it correct within the limits of
sensitivity and other metrological qualities as are
specified In Part III of Fourth Schedule.
10. Power to specify the standard equipment
The Central Government may, by notification,
specify such other standard equipment as it may think
necessary to carry out the provisions of the Act and
every such standard equipment shall conform, as
regards the metrological qualities, to such
specifications as the Central Government may, in the
same notification or subsequent notification, specify.
CHAPTER IV
WEIGHTS OR MEASURES AND WEIGHING AND
MEASURING INSTRUMENTS
U.Welghts
(1) Save as otherwise provided in these rules,
every weight used or intended to be used-
4-::J••
(a). In any transaction, or
(b) for protection,
shall conform, as regards physical characteristics,
configuration, constructional details, materials,
performance, tolerances and such other details, to the
corresponding specifications laid down for such weight
in Fifth Schedule.
(2) The maximum permissible error in respect
of such weight shall be such as is specified In Fifth
Schedule.
(3) Nothing in this rule shall apply to the product
of an Industry which is required, by or under any law
for the time being in force, to conform to any other
specifications with regard to the matters specified In
sub-rule (1) or sub-rule (2), if, under such law, the
product Is required to conform to the specifications
laid down by the International Organisation of Legal
Metrology with regard to the matters aforesaid.
12. Measures (other than measuring
instruments)
(1) Every measure used or intended to be used
for-
(a) any transaction, or
(b) protection,
.· ....
320 THE GAZETTE OF INDIA: EXTRAORDINARY (PART II-SEC. 3(i)]
shall conform, .asc regards physical characteristics,
configuration, constructional details, materials,
performance, tolerances and such other details, to
the corresponding. specifications laid down for such
measure in Sixth Schedule.
(2) The maximum permissible error In such
measure shall .be such as is specified in the
corresponding. specifications laid .down for such
· measure in Sixth Schedule.
13. Welghl~g and measuring Instruments
(1) Every.welghlng lnstrumentused or intended
to be used-
(a) in any transaction, or
{b) for protection,
shall conform, as regards physical characteristics,
configuration, constructional details, materials,
performance, tolerances and such other details, to the
corresponding specifications laid down for such
weighing instrument In Seventh Schedule:
(2) Every measuring instrument used or
Intended to be used-
(a) in any transaction, or
{b) for protection,
shall conform, as regards physical characteristics,
configuration, constructional details, materials,
performance, tolerances and such other details, to the
corresponding specifications laid down for such
measuring instrument In Eight Schedule.
(3) The maximum permissible error on such
weighing or measuring Instrument shall be such as is
specified in the corresponding specifications laid down
for such weighing or measuring instrument In Seventh
Schedule or as the case may be in Eighth Schedule.
14. Procedure for carrying out calibration of
vehicle tanks, etc.
The procedure for carrying out calibration of
vehicle tanks, etc. shall be as is specified In Ninth
Schedule.
CHAPTERV
IMPORT OF WEIGHTS AND MEASURES
15. Registration of Importer
(1) Every manufacturer or dealer of weight or
measure who intends to Import any weight or measure
shall apply to the Director, through the Controller of
the State in which he carries on such business, for
registration of his name as importer In the form
specified in Tenth Schedule.
(2) Every application received by the Controller
under sub-rule (1) shall be forwarded by him to the
Director with a report as to the antecedents and
technical capabilities of the applicant.
(3) Nothing in this rule shall take away or abridge
the right of any person referred to in sub-rule (2) to
carry on the business of importing of any weight or
measure until he has been informed by the Director In
wfitlng that he cannot be registered as an importer,
and on receipt of such letter he shall stop forthwith
the Import of any weight or measure:
PROVIDED that registration of a person carrying
on, at the commencement of these rules, the business
of importing weights or measures shall not be refused
except after giving him a reasonable opportunity of
showing cause against the proposed action.
(4) Every application for the registration of an
importer shall be submitted to the Director, in the
manner aforesaid, together with the fee specified in
Twelfth Schedule, at least one month before the date
on which import is proposed to be made.
(5) The registration of a person as an importer
shall remain effective for a period of five years from
the date of such registration.
(6) On the expiry of the period of registration as
an importer, the Director may, on the application of
the registered importer and on payment of the
prescribed fee, renew registration for a like period.
(7) The registration or renewal of the registration
of a person as an importer may be suspended or
revoked before the expiry of the period of validity
thereof, If the Director is satisfied after an inquiry, and
after giving to the person concerned a reasonable
opportunity of being heard, that any statement made
by such persop in the application for registration or
renewal of registration was false or incorrect In
material particulars or that such person has
contravened any provision of the Act or rules made
there under or any term or condition of such
registration.
16. Conditions, etc. for manufacture of a weight
or measure exclusively for export
( 1) The provisions of this rule shall apply to
weights or measures which are made or manufactured
exclusively for the purpose of export.
(2) No non-standard weight or measure shall
be made or manufactured by any person unless he
has obtained the previous permission from the Central
Government.
(3) Every person intending to manufacture any
non-standard weight or measure for the purpose of
export shall make an application for permission to the
Central Government on payment of a fee of rupees
five hundred for such permission authorising him to
manufacture such weight or measure and shall in such
application Indicate-
(a) his name and full address;
(b) location of the factory in which such weight
or measure is proposed to be manufactured;
(c) description of weight or measure proposed
to be manufactured;
(d) documentary or other evidence indicating the
existence of a firm contract for the export
aforesaid or where there is no such firm
contract for export, documentary or other
evidence Indicating that there is likely to be
a demand for the export of non-standard
weight or measure.
(4) The Central Government shalf, if it is satisfied
from the documentary or other evidence produced by
the applicant or otherwise that the applicant intends
to manufacture non-standard weight or measure for
export, grant the permission authorising him to
manufacture such weight or measure;
Provided that the Central Government may, if it
Is satisfied that the applicant has contravened any of
terms and conditions of the permission or that weights
or measures manufactured by the applicant have found
their way irto the Indian market or that the applicant
had made any statement in his appffcatfon for the
permission which is false In material particulars or he
had concealed some material particulars, cancel the
permission:
Provided Further that no permission shall be
cancelled except after giving to the applicant a
reasonable opportunity of showing cause against the
proposed action.
(5) Every permission granted under sub-rule
(4) shall remain vaffd for a period of one year and
shall be renewed for a like period on payment of a
like fee unless the Central Government is satisfied that
the applicant has made any statement in his application
which is false In material particulars or that he had
concealed some material particulars or had
contravened any provision of the Act or any rule made
there under:
Provided that no order for the refusal to renew
a licence shall be made by the Central Government
except after giving the applicant a reasonable
opportunity of showing cause against the proposed
action.
(6) Every person who is granted permission
under this rule shall submit to the Central Government,
at the end of the calendar year, a statement as to the
quantity of the non-standard weights and measures
exported by him and the particulars of the person to
whom such export has been made.
• 321
17. Prohibition on sale of non-standard weight
or measure within the country
No non-standard weight or measure made or
manufactured exclusively for export shall be sold or
otherwise distributed within the territory of India.
18. Maintenance of record In relation to non
standard weight or measure
Every person who makes or manufactures any
non-standard weight or measure for export shalf
maintain a monthly record of the number of such non
standard weights or measures manufactured by him,
. number of weights or measures already exported by
him, and number of weights or measures in stock or
under production. The record so maintained shall be
open to inspection by any officer authorised by the
Central Government in this behalf.
19. sample checking of weight and measure
(1) Standard weights or measures which are
intended for export shall not ordinarily require any
verification and stamping, but if the party to whom
the export Is to be made so requires, a sample checking
of such weight or measure shall be made by such
agency as the Central Government may specify in this
behalf, and thereupon the agency so specified shall,
after checking the weight or measure, issue a
certificate Indicating whether or not such weight or
measure conforms to the requirements of the Act and
tile rules made there under.
(2) The weight or measure to be checked as
sample under this rule shall be selected at random
and proper records shall be maintained with regard
to the sample checking so made.
(3) The Central Government shall, while
specifying the agency for checking the weight or
measure, ensure that the agency completes the
checking well In time so that the export of the weight
or measure Is not delayed by reason of such checking.
20. Checking of non-standard weights and
measures sample which are to be exported
(1) Non-standard weight or measure, which Is
. made or manufactured exclusively for export, shall
not ordinarily require any verification and stamping,
.but if the party to whom the export is to be made so
requires, a sample checking of such weight or measure
shall be made by such agency as the Central
Government may specify in this behalf; and thereupon
the agency so specified shall, after checking the weight
or measure, issue a certificate Indicating whether or
not such weight or measure conforms to the
specifications given by the party to whom the export
· is to be made or, where the party aforesaid has not
given any specification, whether the weight or measure
conforms to the specifications laid down by the
manufacturer.
--- - _ __J____ ___ _
322 THE GAZETTE OF INDIA: EXTRAORDINARY [PART II-SEC. 3(i))
(2) The weight or measure to be checked as
sample under this rule shall be selected at random
and proper records shall be maintained with regard
to the sample checking so made.
(3) The fee for checking of any non-standard
weight or measure shall be-
(i) if it Is similar to .any standard weight or
measure, ·equal to the fee leviable for the
verification and stamping of such standard
weight or:measure; and
(ii) where such.non-standard weight or measure
is not ·slrnllar to any standard weight or
measure, the Central Government may
specify such amount as fees as is .
commensurate with the labour Involved in
checklng the non-standard weight or
measure.
(4) The Central Government shall, while
specifying the agency for checking the non-standard
weight or measure, ensure that the agency completes
the checking well In time so that the export of such
weight or measure Is not delayed by reason of such
checking.
CHAPTER VI
NON-STANDARD WEIGHT OR MEASURE TO BE USED
FOR SOENTIAC INVESTIGATION OR RESEARCH
21. Permission to get manufactured non·
standard weight or measure for scientific
Investigation or research
Where the manufacture of any non-standard
weight or measure Is needed exclusively for the
purpose of scientific Investigation or research, the
person needing such non-standard weight or measure
shall make an application to the Central Government
for permission to get such non-standard weight or
measure manufactured and on receipt of such
application, if the Central Government is satisfied that
the manufacture of such non-standa.rd weight or
measure is needed for the purpose aforesaid, it may
authorise the applicant to get the non-standard weight
or measure needed by him manufactured by such
manufacturer as he may think fit, and thereupon, it
shall be lawful for such manufacturer to manufacture
the said non-standard weight or measure In accordance
with the specifications given by the applicant.
Explanation: For the purpose of this rule, a non·
standard weight or measure means a weight or
measure which Is, or Is proposed to be, manufactured
In accordance with any unit of weight or measure,
other)han standard unit of weight of measure
specified by or under the Act . . ' ,, '• . .
CHAPTER VII
MISCELLANEOUS
22. The manner of disposal of goods seized
under this Act/rule
(1) Where any goods seized under sub·
section (3) of Section 15 are subject to speedy or
natural decay, the Director or any person authorised
by him or Controller and other Legal Metrology Officers
in this behalf shall have the goods weighed or
measured on a verified weighing or measuring
instrument available with him or near the place of
seizure and enter the actual weight or measure of the
goods In a form specified by the Director for this
purpose and shall obtain the signature of the trader
or his agent or such other person who has committed
the offence. The goods in question shall, after such
weighing or measuring is returned to the trader or
the purchaser as the case may be:
PROVIDED that if the trader or his agent or the
other person (who has committed the offence) refuses
to sign the form, the Director or the person authorised
by him In this behalf shall obtain the signature of not
less than two persons present at the time of such
refusal by the trader or his agent or other person.
(2) Where the goods seized under sub
section (1) are contained in a package and the package
is false or does not conform to the provisions of the
Act or any rules made there under and the goods In
such package are subject to speedy or natural decay,
the Director or any person authorised by him or
Controller an,d other Legal Metrology Officers in this
behalf, so far as may be, may dispose of the goods In
such package in accordance with the provisions of
sub-rule (1).
(3) Where the goods seized under sub-rule (1)
are not subject to speedy or natural decay, the Director
or any person authorised by him or Controller and
other Legal Metrology Officers In this behalf may retain
the package for the purpose of prosecution under this
Act after giving the trader or his agent or the other
person (who has committed the offence) a notice of
such seizure.
23. Time within which unverified weight and
measure to be verified and stamped
No unverified weight or measure, seized under
sub-section (3) of Section 15, shall be forfeited if the
person, from whom such weight or measure was
·seized, agrees to get the same verified and stamped
within a period of ten days or such extended period
from the date of such seizure; and for this purpose,
the person making the seizure of such weight or
rneasure shall afford a reasonable opportunity by
['WI IH!l'"6 3(i)]
returning such weight or measure exclusively for the
verification and stamping.
24. Register and reports to be maintained by
persons referred to In Section 17 of the Act
(1) Every person referred to in sub-section (1)
of Section 17 shall maintain a register In the
appropriate form set out In Eleventh Schedule.
(2) Notwithstanding anything contained In sub
rule ( 1 ), if the Director Is of the opinion that having·
regard to the nature or volume of the business carried
on by any maker, manufacturer, dealer or repairer, it
Is necessary to do so, he may, by order, exempt any
such maker, manufacturer, dealer or repairer from the
operation of that sub-rule.
25. Scale of fee
The scale of fees to be collected for the service
specified in column (2) of Twelfth Schedule shall be
at the rate specified In column 3 of the said Schedule.
26. Useofreglonallanguages ·
Any legend or denomination specified in any
Schedule to these rules, which is required to be
Indicated on any weight or measure in English, or in
Devanagri script, may also be indicated (In addition to
English or Devanagrl) on such weight or measure in
such regional language as the manufacturer may
consider to be practicable.
27. Periodical verlfication.of weights or
measures-
(1) Every weight or measure used or Intended
to be used in any transaction or for protection of living
beings or things In clause (k) of Section 2 shall be
verified and stamped by the Legal Metrology Officer
in the State in which such weight or measure is put to
use and shall be re-verified and stamped at periodical
Intervals.
(2) The re-verification shall be carried out on
the completion of a period of,-
(a) twenty four months for all weights, capacity
measures, length measures, tape, beam
scale and counter machine,
(b) sixty months for storage tanks, and
(c) twelve months for all weight or measure
including tank lorry other than that
mentioned In clauses (a) & (b).
(3) Notwithstanding anything contained in sub
rule (2) every weight or measure which has been
verified and stamped In situ shall, if it Is dismantled
and re-installed before the date on which the
verification falls due shall be duly re-verified and
stamped, before being put into use.
323
(4) Notwithstanding anything contained in sub
rule (1) every weight or m.easure which has been
verified and stamped shall, If It Is repaired before the
date on which the verification falls due shall be duly
re-verified and stamped before being put into use.
28. Qualifications of Legal Metrology Officer
(1) No person shall be appointed as Legal
Metrology Officer uniess he -
(a) Is a graduate of a recognized university In
Science (with physics as one of the subjects),
tech no logy or engineering or holds a
recognized diploma In engineering with three
years professional experience; and
(b) is able to speak, read and write the regional
language of the State.
(2) Nothing in sub-rule ( 1) shall apply to officials
who have been working as Legal Metrology Officer
and are also eligible for promotion to the next higher
grade of Legal Metrology Officer on the date of
commencement of these rules.
(3) The person appointed to the post of Legal
Metrology Officer shall have to successfully complete .
the basic training course at the Indian Institute of Legal
Metrology, Ranchi before his posting.
(4) The Central Government may, In
consideration of the practical difficulties faced by the
State Government and on its recommendation, relax
the qualification specified in sub-rule (1) for the post
of legal Metrology Officers for that State.
29. Nomination of Director by a Company under
the Act
Every company shall inform the Director (Legal
Metrology) or the concerned Controller or his
authorized officer, by notice in duplicate, in the format
specified In Thirteenth Schedule containing the name
and address of its Director after obtaining his consent
in writing, who has been nominated by the company
. under sub-section (2) of Section 49 to be in-charge of
and be responsible for the conduct of business of the
company or any establishment, branch or unit thereof.
30. Repeal and savings
(1) The Standards of Weights and Measures
(General) Rules, 1987 (herein under referred to as
the 'said rules) are hereby repealed.
Provided that such repeal shall not affect:
(a) the previous operations of the said rules or
anything done or omitted to be done or
suffered therein; or
(b) any right, privilege, obligation or liability
acquired, accrued or incurred under the said
rules; or
----.,-----'---
324 THE·GAZETTE OF IND!A:EXTRAORDINARY [PART Il--8EC. 3(i)]
(c) any penalty, forfeiture or punishment
incurred in respect of any offence committed
against the said. rules; or
(d) any investigation, legal :proceedings or
remedy in respect of .any such right,
privilege, obligation, liability, penalty,
forfeiture or·punishment as aforesaid,
And any such ·investigation, legal
proceedings or remedy may be Instituted,
continued or enforced and any such penalty,
forfeiture .or ·punishment may be Imposed
as if the said rules had not been rescinded.
(2) Notwithstanding such repeal anything done
or any action taken or purported to have been done or
taken including approval of letter, exemption granted,
fees collected, any adjudication, enquiry or
investigation commenced, license and registration of
manufacturers, dealers, importers of weights and
measures, non-standard weights and measures or
show cause notice, decision, determination, approval,
authorisation issued, given or done under the said rules
shall.if In force at the commencement of the said rules
continue to be In force and have effect as If Issued,
given or done under the corresponding provisions of
these rules.
(3) The provisions of these rules shall apply to
any application made to the Central Government or as
the case may be the State Government under the said
rules for licence, registration of manufacturers,
Importers, dealers, repairers of weights and measures
pending at the commencement of these rules and to
any proceedings consequent thereon and to any
registration granted In pursuance thereof.
(4) Any legal proceeding pending In any court
under the said rules at the commencement of these
rules may be continued In that court as If these rules
had not been framed.
(5) Any appeal preferred to the Central
Government or as the case may be the State
Government under the said rules and pending shall be
deemed to have beer. made under the corresponding
provisions of these rules.
INDEX OF SCHEDULE OF THE LEGAL METROLOGY
(GENERAL)RULES,2011
PART!
PART II
PART!
· PARTII
PART III
FIRST SCHEDULE
Reference Standard Weights
Reference Standard Metre Bar
SECOND SCHEDULE
Secondary Standard Weights
Secondary Standard Metre Bar
Secondary Standard Capacity
Measures
PART!
PART II
PARTIII
PART!
PART!!
PARTIII
PART!
PART II
PART III
PART!
PART II
PART III
PARTIV
PARTV
PART VI
PART VII
PART VIII
THIRD SCHEDULE
Working Standard Weights
Working Standard Metre Bar
Working Standard Capacity Measures
FOURTH SCHEDULE
Reference Standard Balances
Secondary Standard Balances
Working Standard Balances
FIFTH SCHEDULE
Weights (Other than Carat Weights)
Carat Weights
Standard Weights for testing of High
Capacity Weighing Machine
SDCTlt SCHEDULE
Liquid Capacity Measures
Dispensing Measures
Liquor Measures
Length Measures (Non-Flexible)
· Folding Scales
Fabric or Plastic Tape Measures
Steel Tape Measures
. Surveying Chains
PART IX Tapes for Use in Measurement of Oil
Quantities
SEVENTH SCHEDULE- HEADING A
SPEOF,[CAllONS FOR NON-AUTOMATIC
WEIGHING INSTRUMENTS
PART!
PART II
SEVENTH SCHEDULE- HEADING B
Beam Scales
Counter Machines
SEVENTH SCHEDULE- HEADING C
AUTOMATIC RAIL WEIGHBRIDGE
SEVENTH SCHEDULE- HEADING D
AUTOMATIC GRAVIMETRIC .FIWNG
INSTRUMENTS
SEVENTH SCHEDULE- HEADING E
DISCONTINUOUSTOTAUZINGAllTOMAllC
WEIGHINGINSTRUMENT(TOTAUZING HOPPER
WEIGHERS)
EIGHniSCHEDUi.E
SPEOFICAllONSFORMEASURINGINSTRUMENTS
PART!
PART II
PARTIII
Volumetric Container Filling Machines
Bulk Meters
Water Meters
----- __ t I
['WI IH91"6 3 ( i)]
PART IV
PARTY
PART VI
PART VII
PART VIII
PART IX
Measuring Systems for Liquids Other
than Water
Volumetric Container Type Liquid
Measuring Device
Clinical Thermometer
Manometers of Instruments for
Measuring Arterial Blood Pressure
(Sphygmomanometers)
Taximeter
Compressed gaseous fuel (CNG)
measuring systems for vehicles
NINTli SCHEDULE
PROCEDURE FOR CARRYING OIIT
CAUBRATION OF VEHICLE TANKS ETC.
PART!
PART II
PART III
Calibration of Vehicle Tanks for
Petroleum Products and other Liquids
Method for Calibration of Vertical Oil
Storage Tanks
Method for Computation of Capacity
Tables for Vertical Oil Storage Tanks.
TENnfSCHEDULE
APPUCATIONFO~FORREGISTRATIONOF
IMPORll:R OF\IVEIGHTSAND MEASURES
ELEVENTH SCHEDULE
RE~RTOBE~NTAINEDBYTHE
MANUFACTURERS/DEALERS/REPAIRERS OF
WEIGHTS AND MEASURES
lWELFTHSCHEDULE
SCALE OF FEE
lHJRT!ENTHSCHEDUL.E
Format for no111lnation of the Director
by the Company
FIRST SCHEDULE
DENOMINATIO~,MAll:RIAlS,SHAPEAND
PERMISSIBLE ERRORS, IN RESPECT OF
REFERENCE STANDARDS
[S#JeRule3]
PART I REFERE,.CESTANDARD WEIGHTS
l. Denominations
Kilogram series Gram series Milligram series
(1) (2) (3)
5 500 500
2 200 200
2 200 200
1 100 100
50 50
20 20
'-'r7l! <;6/!J- i'J..
(1)
2. Materials
(2)
20-
10
5
2
2
1
325
(3)
20
10
5
2
2
1
(a) Weights of 5 kg to 1g shall be made from
admiralty bronze (88 Cu, 10 Sn, 2Zn), nickel
chromium alloy (80 Ni, 20 Cr) or austenitic
stainless steel (25 Ni, 20 Cr) or (20 Ni, 25 Cr).
(b) Weights of 500 mg to 10 mg shall be made
from wire of either pure platinum, nickel
chromium alloy (80 Nl, 20 Cr) or austenitic
stainless steel (25 Nl, 20 Cr) or (20 Ni, 25
Cr).
(c) Weights of 5 mg to 1 mg shall be made of
aluminium wire. Copper, silicon and zinc
contained as impurities in aluminium shall
not exceed 0.3 per cent in the aggregate.
Noll!!: The material used for all the weights shall
be non-magnetic and it shall be ensured that the
finished weights are also practically non-magnetic.
3. Shape and finish
(a) For kilogram and gram series-
Integral cylindrical body with knob rounded
at top.
(b) For milligram series-
The weights shall be made from the wire
having five segments for 500, SO, 5 mg
weights, two segments for 200, 20, 2 mg
weights and one segment for 100, 10, and
1 mg weights. One end of the wire shall be
bent at right angles for the purposes of lifting
It with a pair of forceps.
(c) The denominations shall be marked only on
kilogram and gram series weights.
(d) The entire surface of the weights, including
their base and corners shall be free from
any roughness and the surface of the weights
when inspected visually shall not show any
porosity and shall have a mirror finish.
4. Maximum permissible errors
Denomination
(1)
5 kg
2 kg
1 kg
- - ..!- -- ---.- -
Permissible error .1:. mg
(2)
7.5
3.0
1.5
---------
326 -:THE· GAZETTE'OF INDIA: EXTRAORDINARY [PART II-SEC. 3(i)]
(1) .(2)
SOOg 10.75 •
200g :0.30
lOOg :Q:lS
SOg :.0.10
20g 0.080
lOg ·0:060
Sg •.0:050
2g 0:040
lg '0;030
SOOmg 0.025
200mg 0.020
lOOmg O.DlS
SOmg 0.012
20mg 0.010
lOmg 0.008
Smg 0.006
2mg 0.006
1 mg 0.006
s. Protective and canying case
(a) These weights shall be stored In their boxes
made from teakwood or any other suitable
non-corrosive material with proper housing
lined with chemically neutral velvet, chamois
leather or soft plastic material. Wood used
in such boxes shall be reasonably free from
resins and volatile materials. Glue shall not
be used for fixing velvet or such other
material. The weights shall be housed in
such a manner so as to avoid their movement
during transit.
(b) Each milligram weight shall be provided with
·a separate housing. A covering glass or a
sheet of any other transparent and non
reactive and non-corrosive material shall be
provided so as to ensure that these weights
are not dislocated during transit.
(c) A suitable device for lifting the kilogram and
gram weights covered with chamois leather
or other suitable material shall be provided.
A pair of forceps capable of lifting easily
milligram weights shall also be provided.
6. Inscription
The boxes containing the weights shall have the
following inscriptions:
(a) The words 'Reference Standards Weights' .
(b) The Identification number of such boxes,
(c) The name of the manufacturer,
(d) The material used for weights,
(I) kilogram and gram series,
(ii) milligram series,.
(e) The year ormanufacture,
(f) The verification mark of the NPL.
PART II- REFERENCE STANDARD METRE BAR
1. Material
The Reference Standard Metre Bar (hereafter
·called metre bar) shall be manufactured from 58 per
cent nickel-steel.
2. Shape and dimensions
(a) The metre bar shall be of H-sectlon,
approximately 25 mm x 25 mm (as per
Figure 1)
(b) The overall length of the metre bar shall be
1030 ±1 mm and the graduated length shall
be lOOBmm.
(c) Ungraduated space of 11 mm shall be left
after the last graduation mark.
3. Finish
The graduated surface shall be bright highly
polished, and free from surface Irregularities in the
neighbourhood of the graduation marks.
4. Graduations
(a) The main scale shall be situated on the
neutral plane and shall be graduated In
mllllmetres throughout from 0 to 1000 mm.
(b) The main scale shall also have one additional
mm mark before 0 and another after 1000
mmmark.
(c) An additional fine scale shall also be provided
at each end of the main scale for calibrating
a mlcrometre microscope. This fine scale
shall consist of ten 0.1 mm graduations
(1 mm sub-divided into 10 parts) and shall
be situated before the first graduation mark
after leaving a blank space of 2 mm and also
after the last mark with the same blank
spacing.
(d) The graduation marks shall be well-defined,
of symmetrical section and have dean edges.
(e) The width of graduation marks shall be
between 8 and 10 micrometres. This width
shall be constant to within ten per cent over
the length of each mark between the
longitudinal setting lines.
(f) The graduation marks shall not differ in width
one from another by more than ± 10% of
the average width of all the marks.
['flTT II-~ 3(i)]
(g) The graduation marks shall be parallel to
one another to within one mlcrometre
between the longitudinal setting lines.
(h) The graduation marks shall be square to the
scale axis to within ten minutes of arc.
(i) The length of graduation marks shall be as
follows:-
2 mm for half em marks.
1 mm for mm marks.
The marks shall be disposed equally on either
side of an Imaginary centre line.
(j) The lengths of the graduation marks on the
two fine scales referred to In 4(c) shall be
as follows :-
3 mm for first and last mark.
2 mm for 0.5 mm marks.
1 mm for 0.1 mm marks.
(k) The Bessel points shall be indicated by two
vertical lines marked on either external side
of the metre bar. The Bessel points shall be
571 mm apart, and shall be disposed equally
on either side of the 50 mm mark.
(I) No figures or numerals shall be marked on
the surface of the main scale.
( m) When supported at the marked Bessel points,
the graduated surface shall be flat to within
0.05 mm, I.e. all points on the surface shall
be between two parallel planes 0.05 mm
apart. ·
5. Auxiliary scale
(a) An auxiliary scale shall be marked on one of
the top edges of the metre bar.
327
(b) The auxiliary scale shall consist of 1000
marks corresponding to the marks of the
main scale. ·
(c). The marks of the auxiliary scale shall be
. collinear (i.e., passing through the same
vertical planes) with the graduation marks
of the main scale to within± 0.1 mm.
(d) The width of graduation marks shall be not
more than 100 mlcrometres and shall be
clearly visible to the naked eyes having
normal vision.
(e) The length of the graduation marks shall be:
2.5 mm for em marks.
2.0 mm for half em marks.
1.5 mm for mm marks.
One of the ends of all the marks shall lie on
a straight line.
(f) The centimetre graduation marks shall be
numbered in the Increasing order of
numeration.
(g) The height of the numerals and the letters
shall be approximately 3 mm.
6. Setting lines
(a) A pair of longitudinal setting lines shall
transverse the graduation marks and shall
be parallel to the scale axis to within one
minute of arc.
(b) The two longitudinal lines shall be disposed
symmetrically on either side of the centre of
the graduation marks.
-~--~~~4-----~
·~.,.,.~-. '•\
· Ot5<ANC(IIETW€EN
1
t 'II '•:I If ~-!.~. lit• -"hi U tl •. v ~~~r·.· .. ,.
, TWO LO"GlTI,IOII\IAL LINI$
OUP ·~
-·1 --· .. -~--
- ANOAR:; :T-~~ (AC. NI..;.J_·:~i'ER!:NCEi:.STAHDARO LEitS.TH III!ASUflf.(R\) I.G_'_MIIiT 30MBAY- :'' :·
ST .. :r:;:~~· , · 11 · • ., • . !
lll\1!1 lmll' • r . ~::· :: II · tmm_:. ~ -:-tmm
;~1000 ... ~
..
,,.,;o. . . I
--. .--,
t· ·<
T ~· ' :·l
REFERENCE STANDARD METRE BAR
Figure-1
.--· ....
328 ·THE .GAZETTE OF INDIA : EXTRAORDINARY [PART Il--sEC. 3(i)J
(c) The separation of the longitudinal setting
lines shallbe.0.2 mm and<theirwidth shall
be in between.8.and'lO:micrometres.
(d) Each longitUdinal.setti~g:line.shall be straight
to within'30 micrometres.
(e) The longitudinal setting lines shall be parallel
to each.other:to.within 50.micrometres.
7. Maximum permissible error
(a) When the metre bar .is supported on its
marked:Bessel;points, the errors in length
between:any two graduation marks of the
main scalel!tthetemperature of 2o•c, shall
not exceed:0;010·mm.
(b) In the :case of the .fine scales, the error
between any two 0.1 mm marks shall not
exceed 0,005 mm.
8. Inscription
The metre bar shall bear the following Inscription:
(a) the words "REFERENCE STANDARD METRE
BAR"
' (b) the identification number of the metre bar,
(c) the verification mark of the NPL, after the
first calibration and marks of subsequent
verification to be made on the plate of the
carrying case of the metre bar,
(d) the name of the manufacturers,
(e) the material of the metre bar,
(f) the words, figures and letter "STANDARD
AT2o•c·,
(g) the year of manufacture.
9. Protective and carrying case
(a) The standard metre bar shall be housed in
a case made from suitable material and
provided with a handle, lined Internally with
velvet, a plastic material or any other
material and in such a way that the metre
bar is not likely to be damaged, particularly
by shocks or corrosion.
(b) The case shall have affixed on it a plate
bearing the inscription "REFERENCE
STANDARD METRE BAR" and the
identification number.
SECOND SCHEDULE
DENOMINATIONS, MATERIALS, SHAPE AND
PERMISSIBLE ERRORS
IN RESPECTOF$ECONDARYSTANDARDS
[SeeRule4
PART I-SECONDARY STANDARD WEIGHTS
J. Denominations
Kilogram series Gram series Milligram series
(1) (2) (3)
10 500 500
5 200 200
2 200 200
(1)
2
1
2. Materials
1(2)
100
j5o
20
20
10
5
2
2
1
(3)
100
50
20
20
10
5
2
2
1
(a) Weights of 10 kg to 1 g shall be made from
admiralty bronze (88 Cu, 10 Sn, 2 Zn), or
nickel-chromium alloy (80 Ni, 20 Cr) or
austenitic stainless steel (20 Ni, 25 Cr) or
(25 Ni, 20 Cr).
(b) Weights of 500 mg to 50 mg shall be made
from cupro-nickel (75 Cu, 25 Ni), or nickel
chromium alloy (80 Nl, 20 Cr), or austenitic
stainless steel (20 Nl, 25 Cr), or (25 Nl, 20
Cr).
(c) Weights of 20 mg to 1 mg shall be made of
aluminium sheets. Copper, silicon and zinc
contained as impurities In aluminium shall
not exceed 0.3 per cent In the aggregate.
3. Shape and finish
(a) For kilogram and gram series-Integral
cylindrical body with knob flattened at the
top. Weights of 10 kilogram to 100 gram
(both inclusive) shall have adjusting devices.
(b) For milligram series-the weights shall be
In the form of square sheets, one of the
corners being bent at right angle.
(c) The denominations shall be marked only on
kilogram and gram series weights.
(d) The entire surface of the weights, including
their base and corners shall be free from
any roughness and the surface of the
weights, when inspected visually, shall not
show any porosity and shall have a mirror
polish appearance.
4. Maximum permissible error
Denomination Permissible error+ mg
10 kg 50
5 kg 25
2 kg 10
1 kg 5
500 g 2.5
200 g 1.0
100 g 0.5
50 g 0.30
['WI !Hl!US 3 ( i) ]
(1)
20g
lOg
Sg
2g
lg
500mg
200mg
lOOmg
50mg
20mg
lOmg
Smg_
2mg
lmg
(2)
0.25
0.20
0.15
0.12
0.10
0.08
0.06
0.05
O.D4
0.03
0.02
0.02
0.02
0.02
s. Protective and carrying case
(3)
(a) These weights shall be stored In their boxes
made from teakwood or any other suitable
non-corrosive material with proper housing
lined with chemically neutral velvet1 chamois
leather or soft plastic material. Wood used
in such boxes shall be reasonably free from
resins and volatile materials. Glue shall not
be used for fixing velvet or such other
material. The weights shall be housed in
such a manner so as to avoid their movement
during transit.
(b) Each milligram weight shall be provided with
a separate housing. A covering glass or a
sheet of any othertransparent1 non-reactive
. and non-corrosive material shalf be provided
so as to ensure that these weights are not
dislocated during transit.
(c) A suitable device for lifting the kilogram and
gram weights1 covered with chamois leather
or other suitable materiaf1 shall be provided.
A pair of forceps capable of lifting easily
milligram weights shall also be provided.
6. Inscription
The boxes containing the weights shall have the
following inscriptions:-
(a) the words 'SECONDARY STANDARD
WEIGHTS' 1
(b) the Identification number of the secondary
standard weights,
(c) the name of the manufacturer1
(d) the material used for weights
(i) kilogram & gram series
(ii) milligram series1
(e) the year of manufacture,
(f) the mark of verification.
329
PART D· SECONDARY STANDARD METRE BAR
1. Material
The secondary standard metre bar (hereafter
called metre bar) shall be manufactured from 58 per
cent nickel-steel.
2. Shape and dimensions
(a) The metre bar shall have a rectangular cross·
section with dimensions 30mm x 15mm
approximately.
(b) The top surface shall have two rectangular
grooves along its length (as per Figure 2).
(c)· The overall length of the measure shall be
1030 ±1 mril and the graduated length shall
bel010mm.
(d) Ungraduated space of 10 mm shall be left
after the last graduation mark.
3. Finish
The graduated surface shall be bright, highly
polished and free from surface Irregularities in the
neighbourhood of the graduation mark.
4. Graduations
(a) The metre bar shall be graduated in
mllllmetres throughout from 0 to 1000 mm.
(b) A length of 10 mm before the zero graduation
mark shall also be graduated in millimetres.
(c) The scale shalf be regular. The width of the
graduation marks shall be between thirty and
fifty micrometres.
(d) The width of the graduation marks shall be
uniform to within ± ten per cent of the
average width of all the marks.
(e) Each graduation marks shall be straight to
within ten micrometres over its length.
(f) The graduation marks shall be parallel to
one another to within ten micrometres.
(g) The graduation marks shall be square to the
scale axis to within twenty minutes of arc.
(h) The graduation marks representing
centimetres shall be longer than those
representing half centimetres and the
graduation marks representing half
centimetres shall be longer than those
representing millimetres.
(I) The length of the graduation marks shall be
not less than:
2 mm for mm marks.
3 mm for half em marks.
4 mm for em marks.
These marks shall be disposed equally on
either side of an imaginary centre line
defined by the two setting lines.
330 ··THE GAZETTE OF INDIA: EXTRAORDINARY [PART II-SEC. 3(i)]
(j) There shall be two shott longltudinal•setting
lines eachof·5 mm in length which shall be
drawn leaving a· blank space.of 2 mm, the
onE! before the.firstand.the·other after the
last graduation mark. Jhe longitudinalllnes
shall be:on a straight line which repre5ent
the imaglnar,y central·line and the departure
from the.centralline.shall be not more than
O.lmm.
(k) When supported-on :the Bessel points or on
a fl<1i surface :the .graduated surface shall
be flat:to,wlthin 0:05 mm, i.e. all the points
on the•surface shall.be between two parallel
planes:0:05mm apart.
S. Auxiliaryscale
(a) Auxiliary scale shall be marked on one of
the top edges of the metre bar.
(b) The auxnlary scale shall consist of centimetre
and half centimetre marks corresponding to
the marks of the main scale.
(c) The marks of the auxiliary scale shall be
collinear (passing through the same vertical
planes) with the graduations of main scale
towithin±O.l mm.
(d) The width of the graduation marks shall be
not more than one hundred mlcrometres.
(e) The graduation marks representing
centimetres shall be longer than those
representing half centimetres.
' . D ~ • H H
1111111 ~IBiillllilllljUU~U~! IW In llli~UI
'
' " , ..
·- ·- '"'
"
D
SECONDARY STAHOI.RD METRE BAR
FIGURE ·2
(f) The length of the graduation marks shall be
not less than:
3 mm for em marks, and
2 mm for half em marks.
One of the ends of the marks shall lie on a
straight line.
(g) The centimetre graduation marks shall be ·
numbered in the increasing order of
numeration.
(h) The height of the numerals and the letters
shall be approximately 3 mm.
6. Maximum permissible error
The error on the length between any two
graduation marks on the secondary standard metre
bar, at the standard temperature of 20°C, shall not
exceed the value "e" calculated according to the
following formula:
e" ± (25 + L/40) micrometres
Where L Is the nominal length in millimetres of that
part of the metre bar between the two graduation marks,
the error on which is being determined. The calculated
value of"e" shall be rounded to the nearest integer.
7. Inscription
The metre bar shall bear the following
inscriptions:
Q
HYilllll
(a). the words "SECONDARY STANDARD METRE
BAR",
(b) an Identification number of the secondary
standard metre bar,
(c) the name of the manufacturer,
...
I
I
' -·
-lrn~
~ ·]
['WTIH9~ 3(i)]
(d) the material of the metre bar,
(e) the words, figures and letter "STANDARD AT
20°C",
(f) the year of manufacture,
(g) the mark of verification on the plate of the
carrying case of the metre bar.
8. Protective and carrying case
(a) The metre bar shall be housed In a case
made from suitable material and provided
with a handle, lined internally with velvet, a
plastic material or any other material, and
in such a way that the measure Is not likely
to be damaged; particularly by shocks or
corrosion.
(b) The case shall have affixed on It a plate
bearing the Inscription "SECONDARY
STANDARD METRE BAR" and the
identification number.
Note: The existing secondary standard metre
bars may differ In minor details in regard to setting
lines and inscriptions, etc.
PART III-SECOI'IDARY STANDARD CAPACITY
MEASURES
l. Denominations
Litre series (1)
5
2
1
Millilitre series ( ml)
500
200
100
so
20
Note: 111tre = 1 dm' - 0.001 m'; 1 ml= 1 em'
2.Material
Secondary standard capacity measures shall be
cast out of admiralty bronze of the same composition
as is employed In the case of secondary standard
weight.
3. Shape
(a) The secondary standard capacity measure
of five litre shall be cylindrical and have its
inside diameter equal to the height of the
measure. This shall have two handles
attached securely to its sides.
(b) The measure of 2 I and below shall be of
the same shape as above but shall not have
any handles.
(c) The denominations of the secondary
· standard capacity measures shall be
engraved on the outside surface.
(d). Each secondary standard capacity measure
shall be provided with a specially selected
striking glass on the measures and glasses
shall be securely packed in velvet lined
teakwood boxes.
4. Maximum permissible error
Denomination ·
51
21
11
SOOml
200ml
100ml
SOml
20ml
Permissible error+ ml
2
1
0.8
0.5
0.4
0.3
0.2
. 0.1
. 5. Protective and carrying cases
33 I
These capacity measures shclll be stored in their
boxes made from teakwood or any other suitable non·
corrosive material with proper housing lined with velvet,
chamois leather or soft plastic material. Wood used
in such boxes shall be reasonably free from resins
and volatile materials. Glue may not be used for fixing
velvet or such other materials. Each capadty measure
shall be housed in such a manner so as to avoid their
excessive movement during transit.
Each striking glass of the capacity measure shall
be securely housed in proper grooves so as to protect
them from breakage during transit.
6. Inscriptions
The boxes containing these capacity measures
shall have the following inscriptions:-
( a) the Inscription SECONDARY STANDARD
CAPACITY MEASURES;
(b) the Identification number of secondary
standard capacity measures;
(c) the name of the manufacturer;
(d) the year of manufacture;
(e) the mark of verification of proper verifcatlon
authority.
llURDSOIEDULE
DENOMINATIONS, MATERIAL, SHAPE AND
PERMIS5IBI.E ERRORS IN RESPECT OF WORICING
STANDARDS
[See RuleS)
PART I- WORKING STANDARD WEIGKTS
l. Denominations
Kilogram series Gram series Milligram series
(1) (2) (3)
20 500 500
10 200 200
10 200 200
5 100 100
2 50 so
2 20 20
1 10 10
332 THE GAZETTE OF INDIA: EXTRAORDINARY [PART II-SEC. 3(i)]
(2)
2. Material
'(2)
5
2
2
1
(3)
5
2
2
1
(a) Weights. of 20'kg to 1 g shall be cast from
admiralty bronze{88 Cu, 10 Sn, 2 Zn) or
made.from cupro-nickel (75 Cu, 25 Ni) or
nickel .. chromlum alloy (80 Nl, 20 Cr) or
austenltlc:stalnless .steel (25 Nl, 20 Cr) or
(20 Nl,:25 Cr).
(b) Weights of:SOO mgto 100 mg shall be made
from admiralty bronze (rolled) (88 Cu, 10
Zn, 2 Sn) sheets or from the sheets of nickel
chromium :alloy (80 Ni 20 Cr) or austenitic
stainless steel (25 Ni, 20 Cr) or (20 Ni, 25
Cr).
(c) Weights of 50 mg to 1 mg shall be made of
aluminium sheets. Copper, silicon and iron
contained as impurities in the aluminium
shall not exceed 0.3 per cent in the
aggregate.
3. Shape and finish
(a) Weights of 20 kg and 10 kg shall be
cylindrical in shape and shall be cast in two
parts, the top part being screwed snugly into
the bottom part. The top part shall be cast
in the form of a handle for lifting purposes.
The two parts after assembly shall be locked
by means of a set screw over which the seal
of the verifying authority shall be affixed.
(b) Weights of 5 kg to 200 gm (inclusive) shall
be cast In two parts, the top part being
screwed snugly into the bottom part. The
top part shall be cast in the form of a knob
for lifting purposes. The two parts, after
assembly, shall be locked by means of a set
screw, over which the seal of the verifying
authority shall be affixed.
(c) Weights of 100 g to 10 g (inclusive) shall be
as in (b) above except that there shall be no
locking arrangement.
(d) Weights of 5 g to 1 g (inclusive) shall be
integral weights with knob.
(e) Weights of 500 mg to 1 mg (inclusive) shall
be of square shape with the one of the sides
bent at right angles to the flat surface for
ease of handling.
(f) The denominations shall be marked on the
weights.
(g) The entire surface of the weights, including
their base and corners shall be free from
roughness.
The surface of the weights, when inspected
visually, shall not show any porosity and shall have a
mirror polish appearance.
4. Maximum permissible e/TOr
The permissible errors in excess and in deficiency
shall be as follows:-
Denomination Permissible error.± mg
20kg 300
10 kg 150
. 5 kg 75
2 kg 30
1 kg 15
500g 7.5
200g 3.0
lOOg 1.5 .
50g 1.0
20g 0.8
lOg 0.6
Sg 0.6
2g 0.4
lg 0.3
500mg 0.25
200mg 0.20
100mg 0.15
50mg 0.12
20mg 0.10
lOmg 0.08
5mg 0.06
2mg 0.06
1mg 0.06
5. Pro.tectlve and carrying case
(a) These weights shall be stored in their boxes
made from teakwood or any other suitable
non-corrosive material with proper housing
lined with chemically neutral velvet, chamois
leather or soft plastic material. Wood used
In such boxes shall be reasonably free from
resins and volatile materials. Glue shall not
be used for fixing velvet or such other
material. The weights shall be housed in
such a manner so as to avoid their movement
during transit.
(b) Each milligram weight shall be provided with
a separate housing. A covering glass or a
sheet of any other transparent, non-reactive
[ 'lJ1T !H;!f~ 3 ( i) ]
and non-corrosive material shall be provided
so as to ensure that these weights are not
dislocated during transit.
(c) A suitable device for lifting the kilogram and
gram weights, covered with chamois leather
or other sultaqle material, shall be provided.
A pair of forceps capable of lifting easily
milligram weights shall also be provided.
6. Inscription
The boxes containing the weights shall have the
following inscriptions :-
(a) the words 'WORKING STANDARD WEIGHTS',
(b) the identification number of the working
standard weights,
(c) the name of the manufacturer,
(d) the year of manufacture,
(e) the marks of verification.
PARTU- WORJ<ING STANDARD METRE BAR
1. Material
The working standard metre bar (hereinafter I
called metre bar) shall be manufactured from SB per I
cent nickel-steel, or austenitic stainless steel, or I
stainless steel with 13 per cent chromium or pure
1
nickel (minimum purity 99 per cent). 1
2. Shape and dimensions t'
(a) The metre bar shall have a rectangular cross
section of minimum dimensions 20 mm x 10
mm. The existing cross-section with
dimensions 30 mm x 15 mm shall be
preferred.
(b) The overall length of the metre bar shall be
1030 ± 1 mm and the graduated length shall
be 1010 mm.
(c) Ungraduated length of 10 mm shall be left
after the last graduated marks.
3. Finish
The graduated surface shall be bright, nicely
polished and free from surface irregularities In the
neighbourhood of the graduation marks.
4. Graduations
(a) The metre bar shall be graduated in
millimetre throughout from 0 to 1000 mm
on the wider upper surface.
(b) A length of 10 mm before the zero graduation
mark shall also be graduated In mllllmetres.
(c) The scale shall be regular. The thickness of ·
the graduation marks shall be uniform and
shall lie between 30 and BO micrometres. . '
(d) The width of the graduation marks shall be
uniform to within± fifteen per cent of the
average width of all the marks.
333
(e) The graduation marks representing
centimetres shall be longer than those
representing half c-entimetres and the
graduation marks representing half
centimetres shall be longer than those
representing milllmetres.
(f) Each graduation mark shall be straight to
within ten micrometres over its length.
(g) The graduation marks shall be parallel to
one attQther to within ten mlcrometres.
(h) The length of the graduation marks shall be
not less than-
3 mm for mm marks.
5 mm for half em marks.
B mm for em marks.
(I) The centimetres graduation marks shall be
numbered in the Increasing order of
numeration.
(j) The height of the numerals and the letters
(symbols) shall be approximately 3 mm.
(k) The graduation marks shall be square to the
scale axis to within 30 minutes of arc.
5. Cursor
(a) The errors on the length measure under
'Verification shan be determined by means
of a scale marked on a plate, made from
transparent material, whlch·is carried by a
cursor capable of moving along the length
of the metre bar. The plate shall have
appropriate and constant dimensions and
thickness.
(b) The scale on the plate shall :
(I) either be a length of 9 mm divided
into 10 parts thus forming a Vernier
scale to read the errors to the nearest
of0.1 mm; or
(li} one millimetre divided into 10 parts
for reading the errors directly to the
nearest of 0.1 mm.
(c) T))e thickness of the graduation marks on
the scale shall be less than that of the
graduation marks on the metre bar.
(d) The graduation marks on the scale shall be
Inscribed on the surface facing the
graduation marks on the metre bar.
(e) The readings shall be taken by means of a
magnifying glass, the magnification of which
shall be not less than SX if the scale is
graduated in 0.1 mm and not less than 3X If
the scale is of Vernier type.
334 THE GAZETTE OF INDIA: EXTRAORDINARY [PART II-SEC. 3(i))
(f) The cursor shall'be such that lt would be
possible to move it smoothly without jerks,
along a straight line .from one end of the
measure.to the other.
(g) A mechanism to raise, ·fewer and .laterally
move the measure under verification, within
a view to putting its graduated surface at a
proper level and aligning its zero mark with
that of the.metre bar shall be provided.
(h) For facilitating the verification of end
measures, two vertical stops bearing
reference lines shall be provided. The first
stop .shall be .such that its reference line can
be aligned with the zero mark of the metre
bar. The second stop shall be capable of
moving along the entire length of the metre
bar.
6. Maximum pennlsslble errors
(a) The error on the length between any two
graduation marks on the working standard
length measure, at the standard temperature
of 20'C, shall not exceed the value "e"
calculated according to the following
formula:
e = (SO+L/20) micrometres
where Lis the nominal length In mllllmetres
of that part of the metre bar between the
two graduation marks, the error on which is
being determined. The calculated value of
"e" shall be rounded to the nearest Integer.
(b) The errors on the length between any two
graduation lines on the plate shall not exceed
± 20 mlcrometres.
7. Insaiption
The metre bar shall bear the following Inscription:
(a) the words "WORKING STANDARD METRE
BAR';
(b) identification number of the metre bar,
(c) the name of the manufacturer,
(d) the material of the metre bar,
(e) the words, figures and letter "STANDARD AT
20°C",
(f) the year of manufacture.
8. Protective and carrying case
(a) The standard metre bar shall be housed in
a case made from suitable material and
provided with a handle, lined Internally with
velvet, a plastic materia! or any other
material and In such a way that the metre
bar is not likely to be damaged, particularly
by shocks or corrosion.
(b) The case shall have affixed on It a plate
bearing the Inscription "WORKING
STANDARD METRE BAR" and the
Identification number.
Note : The existing working standard length
measure (metre bars) may differ in minor details in
regard to Inscriptions, etc. on it.
PARTW-WORKING STANDARD CAPACrTY
MEASURES
1. ·Denomination
Litre series (I)
10
5
2
1
2. Material
Millilitre series (ml)
500
200
100
50
20
Working standard capacity measures shall be
pressed out of oxygen free, deoxidized annealed
copper sheets of deep drawing quality.
3. Shape
(a) Working standard capacity measure of
10 lltres shall be cylindrical and have its Inside
diameter approximately equal to the height
of the measure. This shall have two handles
attached securely to its sides.
(b) Working standard capacity measures of
Slltres and below shall be of the same shape
as above but shall not have any handles.
(c) The outside of the body of the working
standard capacity measures shall be oxidized
to give a smooth dull black surface and the
Inside shall be tinned.
(d) The denominations of the working standard
measures shall be engraved on the outside
surface.
(e) Each working standard capacity measure
shall be provided with specially selected
striking glass and the measures and glasses
shall be securely packed in velvet lined
teakwood boxes.
4. Maximum pennissible error
Denomination Permissible error in ml :t. ml
10 lltres 8
Slltres 4
· 2lltres 2
llltre 1.5
500 ml 1.0
200m! 0.8
100m! 0.6
50 ml 0.4
20ml 0.2
['ll'T n-= 3(i)J
5. Pipette measures
Pipettes of the following description may also be
used as working standard measures :
(a) One mark pipettes of capacities 10 ml and 5
mi.
(b) Graduated pipettes of capacities 5 ml
graduated at every tenth of mi.
6. Delivery time and maximum permissible
errors of pipette measures
Denomination Delivery time Permissible
ml ---'l"'n-"seco='-'nd:::s'---- error ( + ml)
10
5
5
(Graduated)
Minimum Maximum
15
10
10
25
20
40
7. Protective and carrying cases
0.04
0,03
0.05
These capacity measures shall be stored in their
boxes made from teakwood or any other suitable non
corrosive material with proper housing lined with velvet,
chamois leather or soft plastic material. Wood used
in such boxes shall be reasonably free from resins
and volatile materials. Glue may not be used for fixing
velvet or such other materials. Each capacity measure
shall be housed in such a manner so as to avoid their
excessive movement during transit.
Each striking glass of the capacity measure shall
be securely housed in proper grooves so as to protect
them from breakage during transit.
335
8. Inscriptions
The boxes containing these capacity measures
shall have the following inscriptions :
. (a) the words "WORKING STANDARD CAPACTIY
MEASURES'~
(b) the identification number of the capacity
measures,
(c) the name of the manufacturer.
(d) the year of manufacture,
(e) the mark(s) of verification of proper
verification authority;
FOURlli SCHEDULE
SPECIFICATIONS FOR STANDARD EQUIPMENT
[See Rules 7, 8 and 9]
PARTI-REFERENCE STANDARD BALANCES
1. Every reference standard balance shall be of
such robust construction and have such metrological
qualities so as to ensure the continued good
performance, as indicated in paragraph 2.
2. Sensitivity figure/readability and precision of
measurement of every reference standard balance
shall be such as to give overall precision of
measurement of 1 part in one nilllion for weights from
10 kg to 10 g and± 0.01 mg for weights from 5 g to
lmg.
PARTU-5ECONDARY STANDARD BALANCES
1. Every secondary standard balance shall
conform as regards capacity, sensitivity figure In mg
per division, minimum scale division, variation In
sensitivity figure with respect to load and overall
accuracy of measurement, to the spedfications as
indicated below :
capacity 5enslfiVItY figure Mm. scale diVISion Maximum vanat1on Minimum overall
mg/div. In sensitivity figure accuracy of
with respect to load measurement
1 2 3 4 5
20kg 25 1.5mm 10 per cent 25 mg In 10 kg
5 kg 7.5 l.Omm 10 percent 7.5 mg in 2 kg
1 kg 1.5 l.Omm 10 percent 1.5 mg in 500 g
200g 0.5 l.Omm 10 per cent 0.5 mg in 50g
20g 0.1 l.Omm 10 percent 0.01 mg in 1 mg
2g 0,02 0.75mm 10 percent 0.02 mg in 1 mg
2 .. the standard deviation of the 10 consecutive rest pointS for every secondary standard balance shall not
be more than one scale division.
336 THE .GAZETTE OF INDIA: EXTRAORDINARY [PART II-SEC. 3(i)]
3. The 1devlation·fn arm ratio from unity, for
every secondary standard equi-arm.balance shall not
be more than;a fraction.equal :to sensitivity figure
divided by fullload(both being taken'in the same unit).
4. The variation in time ;periods at different
loads for every secondary standard .balance shall not
be more than 20 per,cent.
5. Every·secondary·standard 'balance shall be
provided with a:device so that the contact between
the knife-edges antlttheir.respective planes is broken
when the balance'is.in atrested position.
6 .. The •secondary .standard balance shall,
ordinarily, be used .for indoor work in laboratories.
7. Every secondary standard balance of digital
type shall conform -as regards value of verification scale
interval as given below:-
capacity Maximum value Type of weights
of verification to be verified
scale interval
20 kg 1 mg 20 kg to 500 g
200 g O.Dl mg 200 g to 1 mg
PARTW- WORKING STANDARD BAlANCES
1. Working standard balances may be of the
following two types:-
( a) Equi-arm types balances;
(b) Digital type balances.
2. Every working standard balance of equl-arm
type shall conform, as regards capacity, sensitivity
figure, maximum variation In sensitivity figure with
respect to load and maximum overall inaccuracy of
measurement to the specification as Indicated below-
Capacity Max. Sensitivity Maximum variation Minimum overall accuracy of
figure/division in sensitivity figure measurement
50 kg 100 mg 20 per cent 100 mg in 10 kg
5 kg 10 mg 20 per cent ·10 mg in 500 g
200 g 1 mg 20 per cent 1 mg in 100 g
50 g 0.4 mg 20 per cent 0.4 mg in 5 g
2g 0.05 mg 20 per cent 0.05 mg in 1 mg
2.1 The standard deviation of ten consecutive
rest points for every working standard balance shall
not be more than one scale division.
2.2 The deviation In arm ratio from unity, for
every working standard equi-arm balance shall not be
more than the fraction equal to sensitivity figure divided
by the full load (both being taken in the same unit).
3. Every working standard digital type balance
shall conform, as regards value of verification scale
Interval as given below:-
capacity Max. value of Type of weights
verification scale to be verified
interval
50 kg 1 g Non-bullion : 50 kg
and 20 kg
20 kg 0.1 g Bullion : 10 kg,
5 kg;
Non-bullion : 20 kg
to2 kg
2 kg 10 mg Bullion : 2 kg to
SOOg;
Non-bu!!lon : 2 kg to
200g
200 g 0.1 mg Bullion : 200 g and
below;
Non-bullion : 200 g
and below
4. The standard deviation of the 10 consecutive
rest points for every working standard balance shall
not be more than one scale division.
5. The deviation in arm ratio from unity, for every
working stand<Jrd equi-arm balance shall not be more
than a fraction equal to sensitivity figure divided by full
load (both being taken in the same unit).
6. The variation in time periods at different load
for every working standard balance shall not be more
than 20 per cent.
7. Every Indoor type working standard balance
shall be provided with a device so that the contact
between the knife-edges and their respective planes
is broken when the balance is in arrested position.
Note: For verification of bullion or carat weights,
only Indoor type working standard balances shall be
used.
FIFTH SOfEDULE
(5ee Rule 11)
PART-I
Weights (Other than Carat Weights}
General
This Part deals with the following categories of
weights:-
--- ---~--- -,--.-----------
[ '11'1 IH!iOs 3( i)]
(A) Iron weights, paralleloplped (SO kg to 5 kg)
(B) Cylindrical knob type weights (10 kg to 1g)
·(C) Iron weights, hexagonal (SO kg to 50 g)
(D) Bullion weights (10 kg to 1 g) and
(E) Sheet metal weights (500 mg to 1 mg)
A.-IRON WEIGHTS PARALLELOPIPED (50 kg to
5kg)
1. Denominations
Paralleloplped Iron weights shall have the
following denomlnatlons:-
Kilogram series : 50, 20, 10 and 5.
2. Shape
(a) The weights shall be integral and in the form
of parallelopiped rectangles with corners
rounded off and having a rigid handle for
ease of handling.
(b) The shapes shall be as shown either in Figure
3 or in Figure 4.
3. Material
(a) Body: The body shall be made or
manufactured from grey cast Iron.
(b) Handles: Handles shall be made or
manufactured from the following materials:
(i) Type 1 weights-Steel tube without
soldering
(ii) Type 2 weights-Cast along with the body
(c) Method of manufacture:
The weights shall be made or manufactured by
means of any suitable foundry and moulding process.
4. Loading holes
(a) The weights shall be provided with loading
holes of either Type 1 or Type 2 Indicated
below:
Tjlpe 1 loading hole
(i) The loading hole shall be located within
the tube which forms the handle (See
Figure 3). .
(ii) The loading hole shall be closed either
with a screwed brass plug or a brass
337
disc. The screwed brass plug shall be
provided with a screw driver slot and
the brass disc shall have a central hole
to facilitate lifting.
(Ill) The plug or a disc shall be sealed by
means of a lead pellet pressed firmly
into an internal circular slot or in the
·threaded part of the tube.
Tjlpe 21oadtng hole
{I) The loading hole shall be cast in one of
the upper surfaces of the weights and
shall open out. on the upper surface
(See Figure 4).
(II) This loading hole shall be closed by a
plate cut from m lid steel.
(Ill) The mild steel plate shall be closed by
a lead pellet pressed firmly into the
conical hole.
(b) In case of new weights, about two-third of
the depth of the loading hole shall remain
empty after adjusbment.
5. Markings
(a) The denomination of the weight and the
marker's or manufacturer's name or trade
mark shall be indicated Indelibly in the sunken
form or in relief, on the upper surface of the
central portion of the weight. (See Figure 3
and Figure 4.)
(b) The denomination of the weight shall be
Indicated in the international form of Indian
numerals in an indelible manner with the
symbols as illustrated below: ·
·fil;ffi or f<nm 5 kg
Note: The abbreviation fll;ffi or f<nm, may be
indicated In the regional script.
6. Dimensions
(a) The dimensions of the two types of weight
shall be as specified in Tables 1 and 2.
(b) The tolerances on dimensions shall be
±5 percent.
TABLEl
Paralleloplped Weights Dimensions for
Type 1 Weights
(In millimetres)
Denomination A A' 8 8' H c D E F GIG'
Skg 150 152 75 77 84 36 30 6 66 12/20
10 kg 190 193 95 97 109 46 38 8 84 12/20
20 kg 230 234 115 117 139 61 52 12 109 24/32
50 kg 310 314 155 157 192 83 74 16 152 24/32
'1 7 1-t c, () tt--f5S'
338 THE GAZETTE OF INDIA: EXTRAORDINARY [PART II-SEC. 3(i)j
Denomination I J K T L N 0 u v w p
5 kg 145 5 12 M16 X 1.5 14 1 2 16.5 18 16 5
10kg 185 6 16 M16 X 1.5 14 . 1 2 16.5 18 16 5
20 kg 220 8 20 M27 X 1.5 21 2 3 27.5 30 27 8
50 kg 300 10 25 M27 X 1.5 21 2 3 27.5 30 27 8
Sides A and A' as also B and B' may be lnversed.
TABLE 2
Para!lelopiped Weights Dimensions for 'TJipe 2 Weights.
(In millimetre$)
Denomination A A' B B' H c D E F G J K M N p
5 kg 150 152 75 77 84 36 30 6 66 19 5 12 16 13 55
10kg 190 193 95 97 109 46 38 8 84 25 6 16 35 25 70
20 kg 230 234 115 117 139 61 52 12 109 29 8 20 50 30 95
50 kg 310 314 155 157 192 83 74 16 152 40 10 25 70 40 148
Sides A and A' also B and B' may be lnversed.
STOPPEft.
VARIIITY I
~-:..-.---- ----c~i~------ =------
•
VARIETY2
IPJ ...
CEAD
PLEI.LET L
~FACTUllERS NAME OR
ADEMARX
~---~
' L .. - -..J
~- ...
PARALLEL PIPED WEIGHT 1YPE I
Figure3
,
[ 'll'l II-<li"S 3 (i ) ] 339
1--f-;:--;~..,.--- A'
~ ·.~
T
- I "? •• 0 I I ' .
! 1
I ! SOUOIWIIlll
l i
I •
• I
L._ • .J
J
I A J
I
. -. !Rounded Corners
~
Manufacturer's Name or Trade Mark
"f,-----,
"-----c
:1_ !mkg
Parallelopiped Weight Type 2
7. Finish
The weights shall be finished smooth and be
free from dross, pits, blow-holes and other defects.
They shall be protected against corrosion by applying
an appropriate coating which is resistant to normal
usage and wear and tear.
8. Permissible error
The maximum permissible errors shall be as
specified below :
Denomination
50 kg
20 kg
10 kg
Skg
9. Stamping
Permissible error
Verification Inspection
(mg) (mg)
7500 ±7500
3000 ±3000
1500 ± 1500
750 ±750
The Legal Metrology Officer's seals shall be
stamped on the lead pellet within the loading hole.
(See Figure 3 & Figure 4).
Figure 4
B.-cYUNDRICAL KNOB TYPEWEIGHTS(lO kg to
lg)
1. Denominations
Cylindrical weights shall have the following
denominations :
Gram series: 500, 200, 100, SO, 20, 10, 5, 2 and 1
Kilogram series : 10, 5, 2 and 1
2. Shape
(a) The weights shall be integral and cylindrical
In shape and provided with a flattened knob
for ease of handling.
(b) The shapes shall be as shown in Figure (5).
3. Material
The weights shall be made or manufactured from
brass, gun metal or bronze; grey cast iron may also
be used for weights from 10 kg to 200 g but grey cast
iron weights shall not be used for weighment of gold,
silver, precious metals or their products.
4. Method of manufacture
The weights shall be made or manufactured by
any suitable method as may be applicable to the
selected material.
5. Loading hole
(a) Weights of denominations 10 g to 1 g both
Inclusive, shall be solid, integral weights
without a loading hole.
-----------------·------~~---- -----------------
340 THE GAZETTE OF INDIA: EXTRAORDINARY (PART Il-8F.c. 3(i)J
(b) Weights ofdenoniinations10'kgto20 g both
inclusive, shall be provided with a loading
hole.
(c) The loading hole shall be cylindrical and shall
pass through the axis .of the weight open
out on the upper surface of the knob and
have wider diameter at its upper end as
shown in Figure 5.
(d) The loading .hole shall be closed either by
means of a 'threaded brass plug or a flat
brass disc. (See Figure 5).
Note: The thread used .shall be that commonly
known as 'ISO Metric'.
(i) The threaded plug shall have a slot
for adjusting it by means of a screw
driver.
(ii) The flat disc. shall be provided with a
suitable hole in the centre to fadlitate
handling.
(e) The plug or the flat disc shall be closed by
means a lead pellet pressed firmly Into the
drcular groove in the wider part of the loading
hole.
(f) .·Weights without a loading hole shall be
adjusted by machining or grinding.
(g) Weights with loading hole shall be adjusted
with heavy metallic materials such as lead
shots.
(h) In the case of new weights about two-thirds
of the depth of the loading hole shall remain
empty after adjustment.
6. Marking
(a) The denomination of the weight and the .
maker's or manufacturer's name or trade
mark shall be indicated indelibly, in the
sunken form or in relief, on the flat knob.
(See Figure 5}.
(b) The denomination of weights of 10 kilograms
to 500 grams may also be indicated on the
cylindrical body of the weight, provided that
the numerals and letters of the symbol shall
be larger than those used for indicating them
on the knob.
(c) The denomination of the weight shall be
Indicated in the international form of Indian
numerals in an indelible manner with the
symbols as illustrated below :
~orf.l;mSkg
m or lJ1ll 100 g
Note :The abbreviation ~. W;n, m or lJ1ll
may be Indicated in the regional script.
7. Dimensions
(a) The dimensions of cylindrical weights shall
be as specified in Tables 3 and 4.
(b) The tolerances on dimensions shall be :
(I) for weights 1 kg. and below± 10 per cent;
(II) for weights above 1 kg± 5 per cent.
TABLE 3
Cylindrical Knob TYpe Weights-Dimension for Weights in mm.
Denomination u v w H y R J K
10 kg 100 90 58 According 17 15 3 10
5 kg 80 72 46 to 13 12 2 10.
2 kg 60 54 36 · material 10 9 2 5
1 kg 48 43 27 8 7 2 5
500 g 38 34 22 6 5.5 1.5 3.2
200 g 28 25 16 4.5 4 1.5 3.2
100 g 22 20 13 4 3.5 1 ·2
50 g 18 16 10 3 2.5 1 2
20 g 13 11.5 7.5 2 1.8 0.5 1.5
10 g 10 9 6 1.6 1.5 0.5 1 Without
Sg 8 7 4.5 1.4 1.25 0.5 1 loading
2g 6 5.5 3 1 0.9 0.5 1 hole
1 g .. 6 5.5 3 1 0.9 0.5 1
['WI Jl-1Ji116 3(i))
'11«1 "" "'""" : 3lm'lRUT 341
TABLE4
Cylindrical Knob Type Weights-Dimension for Loading Hole Variety I and U In mm.
Denominations A 8 c D E
20 g 3 18 . 5.5 2.5 6.5
50 g 4.5 25 7.5 3.5 9
100 g 4.5 30 7.5 3.5 9
200 g 7 40 10;5 4.5 12
500 g 7 50 10.5 4.5 12
1 kg 12 65 18.5 7 20
2 kg 12 80 18.5 7 20
5 kg 18 120 24.5 8 26.5
10 kg 18 160 24.5 8 26.5
. LOADWG tta.E
-.ElY I .. 1
~UEAD~UET
.
~ I. I I
......
..
I
>.~.;_-:;o.l---f--..1
l
~
j ../
t
F G L
1.5 1 9
2 1 10
2 1 10
2.5 1.5 15
2.5 1.5 15
4 2.5. 20
4 2.5 20
4 2.5 35
4 2.5 35
v _j
)Yj
w ~ .......
"' ·, ......
~
~-;.r
u
CYLINIIRlCAL KNOB TYPE WEIGHTS
FIGURE-I
T I M N p s
M4 X 0.5 5 1 5 5 1
M6 x 0.5 5 1.5 7 7 1.5
M6 X 0.5 5 1.5 7 7 1.5
M8 x 1 8 2 10 10 2
M8 x 1 8 2 10 10 2
M14 X 1.5 13 3 18 18 3
M14x 1.5 13 3 18 18 3
M20 x 1.5 18 4 24 24 3
M20 X 1.5 18 4 24 24 3
-HOI.e _,.,.,,
~
UEAD.~~
• p
-~ 8 N
·.·.
342 'THE'GAZETTE OF INDIA: EXTRAORDINARY . [PART IT-SEC. 3(i))
8. Finish
The weights shall be polished smooth. They
may be protected against. corrosion by applying
an appropriate coating. which is resistant to normal
usage and wear· and tear.
9. Permissible error
The maximum permissible ·errors shall be as
specified below :
oenommatiOn
·10 kg
5 kg
2 kg
1 kg
500 g
200 g
100 g
50 g
20 g
10 g
Sg
2g
1 g
10. Stamping
.Permissible error · ·
:verification Inspection
. (mg) (mg)
1500 ± 1500
750 ± 750
300 ± 300
150 ± 150
75 ± 75
30 ±30
15 ± 15
10 ± 10
8 ±8
6 ±6
5 ±5
4 ±4
3 +3
(a) The Legal Metrology Officer's seals shall be
stamped on the load pellet within the loading
hole, where loading hole is provided.
(b) The Legal Metrology Officer's seals shall be
stamped on the bottom of weights which
have no loading hole.
C.-IRON WEIGHTS, HEXAGONAL (50 kg to 50 g)
1. Denominations
Hexagonal iron weights shall hiiVe the following
denominations :
Gram series : 500, 200, 100 and 50.
Kilogram series : 50, 20, 10, 5, 2 and 1.
2. Shape
· (a) The weights shall be integral and hexagonal.
The shape shall be. as shown in Figures 6
and 6A,
(b) The weights of denominations of so kg and
down to and including 5 kg shall be provided
with cast-in handles made of mild steel.
(c) The weights of denominations 2 kg and down
to and Including SO g shall nest with each
other.
3. Material
The ·weights shall be made or manufactUred from
grey cast iron.
4. Method of manufacture
The weights shall be made or manufactured by
means of any suitable foundry and moulding process.
5. Loading hole
The weights must have a loading hole formed at
the foundry
(a) Forweights in Figure 6, this hole must be in
the shape of a right circular cone located
axially and opening into the bottom face of
the weight with its smaller diameter.
(b) For weights in Figure 6A, this hole must be
In the shape of a frustum of a pyramid with
rectangular base and opening into the bottom
face of the weight with its smaller end.
(c) In the case of new weights about two-thirds
of the depth of the loading hole shall remain
empty after adjustment.
6. Marking
(a) The denomination of the weights and the ·
maker's or manufacturer's name or trade
mark shall be indicated indelibly in the sunken
forp1 or in relief, on the upper surface of the
central portion of the weight (See
Figure 6).
(b) The denomination of the weight shall be
. indicated in the international form of Indian
numerals in indelible manner with the
symbols as illustrated below (See Figure 6).
fil;ffi or f.fim 2 kg
m or WI 200 g
Note :The abbreviation fil>ffi, f.fim, 'liT or WI
may be Indicated in the regional script.
7. Dimensions
(a) The dimensions shall be as specified in
Tables s and SA.
(b) The tolerances on dimensions shall be :
(I} for weights 1 kg and below± 10 per cent
(ii) For weights above 1 kg± 5 per cent.
- -~ -- - "-·---- ----- ·--- -----
•
["'JTT II-~ 3(i)] '1m! q;] ~ : 3lm'lR"' 343
TABLES
Dimensions for cast Iron or Forged
Mild Steel S Weights
(All dimensions In millimetres)
Denomination A 8 c D. H p Q R s T
2kg_ 94 101 78 41 10 34 30 9 18 4
1 kg 73 79 62 34 8 32 28 8 16 4
500g 57 62 47 27 6 23 20 6 13 3
200g 42 48 38 21 6 22 20 4 9 3
100g 33 38 31 17 5 18 16 3 7 2.5
50g 27 31 24 u· 3 16 14 3 5 2
TABLE SA
Dimensions of Cast Iron Weights with Cast-in Handles
Denomination A 8 c D E
50 kg 236 253 134 170 100
20 kg 188 200 112 113
10 kg 152 161 92 88
Skg 125 132 75 65
8. Finish
The weight shall be finished smooth and be free
from pits, blow-holes and other defects. They shall
be protected against corrosion by applying an
appropriate coating which is resistant to normal usage
of wear and tear.
9. Permissible error
The maximum permissible errors shall be as
specified below ;
Denomination Permissible error
90
74
62
Verification Inspection
50 kg
20kg
10kg
5 kg
2 kg
1 kg
500g
200g
100g
50g
(mg)
7500
3000
1500
750
300
150
75
30
15
10
(mg)
±7500
±3000
±1500
±750
±300
±150
±75
±30
±15
±10
(Dimensions in mm)
G p Q R s T
27 58 48 24 102 32
21 44 38 19 66 22
18 36 30 15 54 19
15 29 25 12 40 16
10. Stamping
The Legal Metrology Officer's seals shall be
-stamped on the lead pellet within the loading hole
-(See Figure 6).
CAST IROtl Olt Hli\OEO ~ILO S'l'f.il,
'.100 W-11 /lf,llllu FIG- 6
r-·-----~
I['~~~
.-------'-<-·a..:.-----·~
FIC IM:.u<T lltON 'llrU'ilfl5 WlT!I..:AST·r-IIW'ftl~f,
D.-6UWON WEIGHTS {10 kg to 1 g)
1. Denominations
Bullion weights shall have the following
. denominations ;
Gram series; 500, 200, 100, 50, 20, 10, 5,
2 and 1.
Kilogram series : 10, 5, 2 and 1.
___ ,
344 'THE·GAZE'T·TE OF ·INDIA: EXTRAORDINARY [PARTll-SEC. 3(i)]
2. Shape
Bullion w~jghts shall be of:the followi~g .,two
types:
bottom face of the welg ht with its smaller
diameter (See Figure 7).
(d) In the case of new weights about two-thirds
of the depth of the loading hole shall remain
empty after adjustment.
(i) Cylindrical:knob types--'Cylindrical knob type .
weights cif denomination 10 kg to 1 g, both
inclusive, shall be·otthe shape as specified
in pa~graph:B,2.of this Part (See also Figure
5) but :shall bear .indiCations, specified In
paragfi!ph6 to lndicate·that·they are bullion
weights.
6. Marikings
(ii) Flat <;ylindrlcal type--;Fiat cylindrical type
weights of< denominations 1 kg to 1 g both
incluslve,,shall be ·flat cylindrical In shape,
without a: knob and shall nest with each other
(See figure .7).
3. Material
Weights shall be made or manufactured from
brass, gun meta!, ·bronze or the like.
4. Method of manufacture
Weights sl:lall 'be either cast, pressed or turned
from rods, or :made or manufactured by any other
suitable method .as may be applicable to the selected
material.
s. Loading holes
(a) Weights of denominations 10 kg to 20 g, both
inclusive, made or manufactured according
to requirements specified in paragraph 11
of this Part, shall have loading holes of the
type specified for them.
(b) Weights of denominations 10 g to 1 g, both
inclusive of either type shall be solid Integral
weights without a loading hole,
(c) Flat cylindrical weights from 1 kg to 20 g
both Inclusive, shall have loading holes, in
the shape of a right circular frustum of a
cone located axially and opening Into the
TABLE6
(a) The denominations and other marking on
cylindrical knob type weights shall be as
specified in paragraph 15 of this Part.
(b) Cylindrical knob type weights of
denomination 100g to 1g, both inclusive,
shall be marked on the body with a 'diamond'
and those of denominations 10 kg to 200g,
both inclusive, shall be marked on the knob
with the words 'Bullion' and (~)within
a 'diamond'.
(c) The denominations of flat cylindrical weights
and the maker's or manufacturer's name or
trade mark shall be Indicated indelibly, in
the sunken form or In relief, on the upper
surface of the central portion of the weights
(See Figure 7). ·
(d) Flat cylindrical weights of denominations 10
g to 1 g, both inclusive, shall be marked with
only a 'diamond'. and those of denominations
1 kg to 20 g, both inclusive, shall be marked
with the words 'Bullion' and(~) within
a 'diamond'. ·
(e) The denomination of the weight shall be
Indicated in the international form of Indian
numerals in an indelible manner with the
syl)lbols as illustrated below (See
Figure 7):
q or f.l;m 2 kg
'!IT or '!fl11 10 g
DIMENSIONS FOR FLAT CYUNDRICAL BULUON WEIGHTS
(All dimensions in millimetres)
Denomination A 8 c D E F G
1 kg 80 61.5 20 23 4.0 12 26.6
500g 61 48.5 16 19 2.5 10 22.5
200g 48 37.5 14 16 2.0 7 14.8
lOOg 37 28.5 12 14 2.0 6 12.7
50g 28 21.5 10 11 1.5 3 11.0
20g 21 16.5 9 10. 1.5 3 8.4
lOg 16 12.5 ** ** 1.5 ** 6.9
Sg 12 9.5 ** ** 1.0 ** 5.9
2g 9 7.0 ** ** 1.0 ** 4.4
1g 6.5 ** ** ** ** ** 3.6
- -· -- -------,----
·. ·•.
[ 'lT'T I Hllll"!f 3 ( i) ] "1m! "" ~ : arn!'IR"J . 345
A0
l I 80
I
~ re- -~--------- -i------------J
I
1 ir-- ----:---
' -ce-
--oB-
Flat Cylindrical Bullion Weights
Figure -7 ·
Note :The abbreviation fll>ffi, 1ll;m, m or WI
may be indicated In the regional script.
7, Dimensions
(a) The dimensions of cylindrical knob type
weights shall be as specified In Tables 3 and
4.
(b) The dimensions of flat cylindrical weight shall
be as specified in Table 6.
(c) The tolerances on dimensions for bOth types
of weights shall be-
(i) for weights 1 kg and below± 10 per
cent.
(ii) for weights above 1 kg ± 5 per cent.
8. Finish
The surface of the weights shall be polished,
smooth and shall not show any porosity to the naked
eye.
9. Permissible error
The maximum permissible errors shall be as
specified below :
Denomination
(1)
10kg
5 kg
2kg
1 kg
SOOg
Permissible error
Verification Inspection
(mg) (mg)
(2) (3)
500
250
100
50
25
±500
±250
±100
±50
±25
(1) (2) (3)
200g 10 ±10
100g 5 ±5
SOg 3 ±3
20g 2.5 ±2.5
lOg 2.0 ±2.0
Sg 1.5 ± 1.5
2g 1.2 ±1.2
lg 1.0 ± 1.0
· 10. stamping
(a) The Legal Metrology Officer's seals shall be
stamped on the lead pellet within the loading
hole, where loading hole is provided.
(b) The Legal Metrology Officer's seals shall be
stamped on the bottom of weights which
have no loading hole.
E.-sHEET METAL WEIGKTS
1. Denominations
Sheet metal weights shall have the following
denomlnatlons:-
MIIIIgram series: 500, 200, 100, 50, 20, 10, 5, 2
and 1.
:z.. Shape
(a) Bullion weights shall be circular in shape and
shall have one edge bent for ease of hand I ing
(See Figure 8).
(b) Non-bullion weights shall have the following
shapes and shall have one edge bent for
ease of handling (See Figure 9).
Denomination (mg)
5, 50, 500
2,20,200
1, 10, 100
3. Material
Shape after bending along
one of the sides
Equilateral triangle
Square
Regular hexagon
Sheet metal weights shall be made or
manufactured from brass, stainless steel, aluminium
nickel-sliver or cupro-nickel sheets.
4. Method of manufacture
Sheet metal weights shall be made or
manufacture by pressing or by any other suitable
process.
5. Markings
(a) Sheet metal weights shall bear only the
denomination and symbol for 'milligram' as
346 .THE GAZETTE OF INDIA: EXTRAORDINARY [PART II-SEC. 3(i)J
TABLE7
DIMENSJ:ONS FOR SHEET METAL WEIGHTS
(NON-BULUON) (Figure 9) (All dimensions In mill/metres)
Denomination A1 A2 A3 8 H
(mg)
50 14.0 2.0 3.0
200 12.0 2.0 3.0
100 12.0 2.0 2.5
50 8.0 1.5 2.5
20 7.0 1.5 2.5
10 7.0 .1.5 2.5
5 4.5 1.0 . 2.0
4.0 ... 1.0 2.0
4.0 1.0 2.0
indicated below (See also Figure 8 and TABLES
DIMENSJ:ONSFORSHEETMETAL WEIGHTS
(BULUON)(Figure8)
Figure9). ·
(firnT) 500 mg (All dimensions in mill/metres)
D C H
Note :The abbreviation flrnT may be Indicated
In the regional script.
Denomination .,
500 mg
200 mg
100 mg
50 mg
20 mg
·10 mg
15
13
11
9
8
7
6
5
2.0
2.0
2.0
1.5
1.5
1.5
1.0
1.0
1.0
3.0
3.0
2.5
2.5
2.5
2.5
2.0
2.0
2.0
(b) The maker's or manufacture's name or trade
mark shall be indicated indelibly on the box
containing the sheet metal weights.
· (c) The box shall also bear a serial number to ·
identify it.
6. Dimensions
(a) The dimensions of sheet metal weights shall
be as specified in Tables 7 and 8.
(b) The tolerances on dimensions shall be
± 10 per cent.
Denomination (mg}
5 mg
2 mg
1 mg
7. F1nlsh
4
The sheet metal weightS shall be clearly sheared
and free from burrs. The stamped markings on sheet
metal weights shall be legible and deep enough to
ensure Indelibility but not so deep as to crack the sheet
metal weights.
8. Permissible error
The maximum permissible errors shall be as
specified below :
Verification
Maximum permissible error ·
TnSoection
Bullion (mg} Non-bullion (mg} Bullion (mg} Non-bullion (mg}
soo 0.8 2.5 ±0.8 ± 2.5
200 0.6 2.0 . ± 0.6 ±2.0
100 0.5 1.5 ±0.5 ± 1.5
so 0.4 1.2 ±0.4 ± 1.2
20 0.3 1.0 ±0.3 ± 1.0
10 0.25 0.8 ± 0.25 ±0.8
5 0.20 0.6 ± 0.20 ±0.6
2 0.20 0.6 ± 0.20 ±0.6
1 0.20 0.6 + 0.20 + 0.6
[ '1T'T IH!i116 3 ( i) ]
9. Stamping
(a) ·Legal Metrology Officer's seals shall not be
affixed on weights of 10 mg, 5 mg, 2 mg
and 1 mg. These weights shall be
Figure 8
347
authenticated by the Issue of a certificate of
verification which shall also mention the serial
number on the box containing the weights.
(b) Legal Metrology Officer's seal for year alone
shall be stamped on sheet metal weights of
20 mg.
Sheet Metal Bullion Weights
500
D
'
H " soo ' I J, I
f1:rn"r mg
I
I H 200
T ·•·
, f1:rn"r mg
A, B ~,.,_J
Flgure9
Sheet Metal Weights
H
1
....
I
I
I
I
I
J
~
' \
\
\
~
-~------
348 .THE GAZETTE OF INDIA: EXTRAORDINARY (PART ll-SEC. 3(i)]
(c) The Legal Metrology·0ffice(s ,seals .(namely,
year, quarter and identification) shall be
stamped on sheet metal weights of
denominations· 500 mg to ·so mg, both.
indusive.
1. General
PART II
CARAT WEIGHTS
This Part deals with the requirements for carat
weights intended for use in weighing pearls, diamonds
and other precious stones.·
2. Denominations
The denominations of carat weights shall be as
given below (the gram ·and .milligram equivalents are
shown against each for ·ready reference) :
(a) KNOB WEIGHTS (b) SHEET METAL WEIGHTS
Denomination Equivalent Denomination Equivalent
carat g carat mg
500 100 2 400
zoo 40 1 200
100 20 0.5 100
50 10 0.2 40
20 4 0.1 20
10 2 0.05 10
5. 1 0.02 4
0.01 2
0.005 1
3. Knob weights
(a) Materials
(i) The weights shall be made from
rolled, drawn or extruded material
and shall not be cast.
(ii) The weights shall be made from
brass, bronze, gun-metal, nickel
chromium alloy or non-magnetic
stainless steel.
(b) Shapeanddimenslons
The shape and dimensions of the weights
shall be as shown in Figure 10 and Table 9.
(c) Permissible error
The maximum permissible errors shall be
as specified below :
Denomination Verification Inspection
Carat mg mg
500 5.0 ±5.0
200 3.0 ±3.0
100 2.5 ±2.5
50 2.0 ±2.0
20 1.5 ± 1.5
10 1.2 ±1.2
5 1.0 ±1.0
TABLE9
NOMINAL DIMENSIONS OF KNOB CARAT WEIGKTS
[Clause 3(b)]
(All dimensions in millimetres)
Denominations Carat A* C** D E F G H
500 12.0 0.4 4.0 10.0 6.0 32.0 14.2
200 10.0 0.4 3.0 8.5 5.0 23.0 10.8
100 8.0 0.4 2.5 7.0 4.0 19.0 7.9
50 6.0 0.3 2.0 5.5 3.0 15.0 6.4
20 5.0 0.3 2.0 4.0 2.0 11.0 4.6
10 4.0 0.3 1.5 3.0 1.5 9.0 3.5
5 3.0 0.2 1.5 2.5 1.5 7.0 2.9
* The cross-section of the top of the knob is elliptical for all weights major axis being twice the minor axis
(therefore for all weights 8= A/4)
* * This Is a recommended dimension .
. ,. f-. •" ~----· ., -..r ~,,.,. • -• r .,., ·1f''rflr·•"~
___ .l ____ L.. I!
------·~~----,--~------:---;--c--:----
['ll'l II ~ 3(i)] 349
Note :With a material of density 8400 kg/m'
(exactly) the above dimensions will give weights which
possess masses to within the required tolerance limits
on the plus side (this ensures a longer life for the
weights). However, as the density of the material may
vary considerably as also the manufacturing
techniques, a tolerance of ±10 per cent Is allowed on
all obligatory dimensions (that is those other than C).
Final values of masses can be adjusted by controlling
the dimension H.
Denomination
carat
VerifiCiltfon Inspection
4. Sheet metal weights
(a) Materials-weights of denominations 0.2
carat and below shall be made of aluminium
sheet. Weights of higher denominations
shall be made of sheets of brass, aluminium,
nickel-silver, nickel chromium alloy, bronze
or cupro-nlckel.
(b) Shape and dimensions-sheet metal weights
shall be square with one edge bent for ease
of handling (See Figure 11). They shall
have dimensions given in Table 10.
(c) Permissible error
The· maximum permissible .errors shall be as
specified below:-
1
2
1
0.5
0.2
0.1
0.05
0.02
0.01
0.005
mg·
2
0.8
0.6
0.5
. 0.4
0.3
0.25
0.20
0.20
0.20
TABLE10
mg
3
±0.8
±0.6
±0.5
±0.4
±0.3
±0.25
±0.20
±0.20
+0.20
Nominal dimension for sheet metal carat
weights
Denomination Size
carat mm
2 12
1 10
0.5 9
0.2 8
0.1 7
0.05 6
0.02 5
0.01 4
0.005 3
Tolerance± 10 per cent
Manufacturers Name or
Trade Name
Figure 10
Knob Carat Weight
H
Figure 11
Sheet Metal Carat Weight
350 '{fHE(GAZEITE 'OF INDIA: EXTRAORDINARY [PART IT--SEC. 3(i)]
5. Manufacture andllnWI
(a) The surface of '.the ·weights shall be
reasonab)y smooth. Sheet :metal weights
shall be smoothly sheared and shall be free
from burrs.
(b) For better stabllicy and finish, the weights
· may be nlckel,cor,~hodium :plated.
6. Marking
(a) Every welght,,e,xcept weights of 50 carat and
lower •denominations, shall have the
manufacturer's name or trade mark and the
denomination .Indelibly marked on it.
(b) The denomination shall consist of the
International form of Indian numeral prefixed
and s~xed by the letter·~· and 'c'
respectively except that in the case of
weights below 50 carat, only the numerals
shall be marked. The size of numerals and
letters Indicating the denomination of
weights shall be at least twice the size of
letters Indicating the manufacturer's name
or trademark.
Note :The abbreviation·~· may be indicated
in the regional script.
(c) The marking shall be legible and deep
enough to ensure indelibility over a long
period of use, but not so deep as to crack
the weight itself.
7. Packing
(a) Each set of carat weights shall, In addition
to the series of denomination specified under
2, consist of an additional piece of weight of
2 carat and the relevant decimal multiple of
two.
(b) The weights shall be supplied In a suitable
velvet-lined box. The. small sheet metal
weights shall be so housed and provided with
a cover of glass or any other transparent
material that they will not get dislodged from
their proper places. The box shall also
contain a pair of forceps for lifting the
weights.
PART III
STANDARD WEIGHTS FOR TESTING OF HIGH
CAPACITY WEIGHING MACHINES
1. Scope
These specifications shall apply to standard
weights having a nominal value equal to or greater
than 50 kg, used for testing (and adjusting, where
appropriate) of high capacity weighing machines In
accuracy class III (medium) and class IV (ordinary),
defined In the Metrological regulations for non
automatic weighing machines.
(a) It sets forth the technical and metrological
requirements to which these standard weights must
conform. In particular it establishes the values of the
maximum permissible errors for standard weights and
minimum densities as functions of the maximum
number of scale divisions on the machines to be
verified using these weights.
2. Nominal values •
The nominal value of the standard weight Is 50
kg, or of the form k x lOn kg, where k is generally
. equal to 1, 2 or 5, and n is whole number equal to or
greater than 2.
3. Shape
' The standard weights must have a relatively
simple shape, with no sharp edges or corners. They
shall not have any cavities liable to cause a rapid
accumulation of dirt. If they are intended to run on a
flat surface (or on rails), they must be equipped with
roller tracks (or grooves) of limited area.
4. Basis of adjustment