These rules shall be called as Special Regulations (Building) 2009.
Rules made under The Goa,Daman and Diu Town and Country Planning Act 1974
This text is shown as one document.
Full text
\
I
• I SERIES·
Daman 15th January, 2010, 25 Pausa 1931 (Saka) "('i.: 01
No.
.- -... - .. - -., ,~.,- 1 ~
,{.I~ (l'*IQ51
OFFICIAL GAZETTE
--
U.T. ADMINISTRATION OF DAMAN & DIU
~&ro~
PUBLISHED BY AUTHORITY
U.T. ADMINISTRATlON OF DAMAN AND DIU
TOWN AND COUNTRY PLANNING DEPARTMENT
MOTlDAMAN
No ATP/DMN/Spl Rules(B)/1294/09/556 Dated:24/12/2009
NOTIFICATION
In exercise of the powers conferred by Section 140 of the Daman & Diu Town and
Country Planning (Amendment) regulation, 1999 (Read with principal Act Goa, Daman & Diu
Town and Country Planning Act 1974), the Administrator is pleased to make the following
Special Regulations for Buildings Vulnerable to manmade disaster in whole U.T of Daman
and Diu.
1. Short Title, Extent and: (1) These rules shall be called as Special Regulations
Commencement (Building) 2009.
(2) These regulations shall be applicable to the whole
U.T of Daman and Diu from the date of its
notification in the Official Gazette.
(3) These Special Regulations shall be applicable to the
building Vulnerable to terrorist attack within the U.T
of Daman and Diu.
2. Savings : In these rules unless the context otherwise requires, the terms and
expressions shall have the same meaning as indicated in the
Development Control Rules, 2005 of Daman District. The terms and
expressions not defined in those rules have the same meaning as in the
Goa,Daman & Diu Town and Country Planning Act, 1974( Act 21 of
1975).
COntrl./--
-2-
SERIES - I No.: 01
DATED: 15TH JANUARY, 2010.
3. Definitions:
(i) building enlisted below shall be "The Building Vulnerable to manmade
Disasters" like terrorist attack etc.
(a) All buildings that have been specified specially identified by the appropriate
Authority of the U.T Administration.
(b) All Assembly Buildings.
(c) Institutional buildings of Government, Semi Government Organizations,
Prisons, Courts(having built up area exceeding 10,000 Sq.mt or occupancy
over 1000)
(d) Institutional Building of registered Trust which are used for Medical or other
treatments, Hospitals (having built up area exceeding 10,000 Sq. mt or
occupancy over 1,000)
(e) Educational Building of School/Colleges (having built up area exceeding 10,000
Sq mt or occupancy over 1,000)
(f) Building which attract or are likely to attract large number of people/ public,
such as shopping malls, Markets, Religious Building. Large
intercontinental Hotels, Monuments, Places of Tourist importance, Exclusive
Business Building (like world trade Center, Stock Exchange) etc.
(g) Hazardous Buildings as defined in National Building Code.
(h) Any other Building specifically categorized by Government/UT Administration.
(ii) "Appropriate "or "Competent Authority" of Police Department as mentioned in these
regulations shall mean Deputy Inspector General of Police, Superintendent of Police,
Additional Superintendent of Police and the Chief of Police in districts of U.T of
Daman and Diu.
(iii) "Building Security Advisory Committee" shall mean such a committee of officials and
experts specially appointed for purpose of security and general advice to the
Concerned Authority or Planning Authority on any Security proposals for new building
or for existing buildings vulnerable to terrorist attack.
4.0 General Requirements:
4.1 Open Spaces for "The Buildings Vulnerable to tei rorist Attack" shall be provided with
a safe perimeter or blast stand off distance delineated with positive barriers and a
system that prevents any attackers approaching within that Zone.
4.2 Marginal Distances required as follows:
As per building line prescribed for National Highway State Highway/ Major road or 9m
from the boundary of the road, whichever is more.
4.3 Compound wall shall be 2.0 m in height or as specified in these regulations. ( The
height may be reduced to 0.75 m if line of sight gets affected in which case the
balance height shall be made up of vertical strong steel rods).
COntd./-
Page 2 of9
-3-
SERIES - I No.: 01
DATED: 15TH JANUARY, 2010.
4.4 At the corner plot the boundary wall for length of 10 mt on the front and side of the
intersection shall be constructed of masonry/Concrete up to a height of 0.75m and the
balance height shall be made of iron mesh or a railing of suitable size and thickness .
However, this provision shall not be applicable to the boundary walls of jails.
4.5 The approach to the building shall be provided with sufficient restraints to prevent any
direct movement of vehicles towards the structures. There shall not be ordinarily more
than two entry points, one for persons & other for materials. The outer perimeter
except porch entrance area of the structure shall be protected with an RCC kerb of
height not less than that 600mm and thickness not less than 450 mm.
4.6 An additional standoff shall be provided to reduce the effect of an explosion at closer
distance of not less than that approved by the competent authority of the Police
Department.
4.7 Parking shall not be provided in the minimum marginal open spaces.
4.8 In case of building requiring security control measures, a security outpost shall be
provided near the entry control as stipulate in these regulations. It shall be mandatory
to provide a Security outpost while constructing the above mentioned public bUildings.
4.9 The area of control room/security outpost provided in such buildings not exceeding the
area as per the requirements of the appropriate authority appointed for this purpose
(but not more than 45 sq. mts) shall be excluded from computation of FSI.
4.10 The detailed requirement of the Security outpost are as below:
(a) There shall be one security post not less than 45 sq. mt built up area, if the plot
area of such a public building is more than 5,000 sq. mt and 30 sq.mt built up
area. If the plot area of such a public building is less than 5,000 sq.mt and shall
be located near the entrance gate.
(b) Fire resistant material shall be used for construction (two hours fire rating)
(c) The security outpost shall have minimum one store room along with the toilet block
and two doors. Windows shall be made using bullet proof glass with shatterproof
membrane on either side.
(d) Latest electronic system for surveillance purpose shall be provided in consultation
with the Appropriate AuthOrity of Police Department.
Note:
(i) The area of such type of security outpost shall not be counted in the F.S.I of the
building, up to a maximum of 45 sq mt.
(ti) Such type of construction may be used as the normal security post of the owner
for entry control but shall be handed over free of cost for use to Police Department
whenever demanded/required during emergencies or for monitoring visits.
iii) Minimum clear distance between the main building and the security post shall be
4.50 mt.
Contd.j-
Page 3 of9
-4-
SERIES - I No.: 01
DATED: 15TH JANUA :-::: R~y,=-:2 -:C 01 :-::: 0 -.
4.11 It is mandatory that a control room be provided for use by the owner/occupier
controlling and monitoring various Security and Surveillance operations.
4.12 The requirements of the Control room shall be as given below:
(a) The control room shall be centrally located but shall be away from the m<
entrance of the building.
(b) Control rooms shall be provided with escape routes at suitable locations.
(c) Control rooms shall be designed as blast resistant strong rooms and shall be
sustaining with full independent provisions for water, electricity
communications. These rooms shall be provided with essential survival kits for
least 72 hour period.
(d) The walls of control rooms shall be made of either 60 cm thick rein
masonry using bricks or PeC Blocks of strength not less than 50 Kgs/sq.
45 cm thick R.C.C. with a minimum reinforcement of 0.2% or normal
armored with 12 mm thick steel sheets or fiber wrapping of equivalent stre
(e) The door shall be provided with steel guard bars or grills. The main entry'
the room or the control area shall be provided with steel armored gates h
a minimum thickness of 12 mm.
(f) The control room should also house the centralized control system of
building. Any window for ventilation shall be suitably protected with bullet
and shatter proof membranes.
(g) The control room shall be suitably ventilated and care taken to ensure fool
safety of this ventilation arrangement.
4.13 Adequate water discharging capacity and provisions shall be made to prevent fi
in case of damages to overhead water tanks, water supply lines etc.
4.14 A proper access control from the terrace to the building shall be provided in the
of locked door with proximity control to be activated and deactivated from the
room.
S.O Requirements for Electrical and Electronics Systems.
5.1 Electronic Surveillance Systems shall be installed at various locations in and out of
building as may be required and with previous approval of the Appropriate Authority
Police Department having regard to the degree of perceived risk. A suitable con
room shall be provided within the premises for monitOring as mentioned earlier in 11.
above.
5.2 CClV coverage of all important locations and vital installations shall be done includir
main gate, reception, utility areas and common open areas on fioors, lifts, lobbies ar
the compound. Perimeter lighting outside the building shall be adequate with focus i
critical areas and movable search lights at corners.
Page 4 01
-5-
SERIES - I No.: 01
DATED: 151ll JANUARY, 2010.
5.3 All electronic systems, electrical systems, security systems and minimum services to the
Control Room shall be provided with three tier system arrangement consisting of (1)
main supply (2) Standby generating system (3) inverter or UPS system, so as to have
continuous and interrupted supply and shall comply with the provisions of IS codes.
Indian Electricity Rules, 1956 and National building Code.
5.4 All provisions of National Building Code in respect of electrification shall be applicable.
In addition, the following requirements shall also apply regarding the illumination levels
etc. in different areas in respect of security:-
(a) Maximum to average ratio of luminance should not be more than 3: 1.
(b) Luminance level for vertical illumination at 1.5 m above ground should be equal to
horizontal luminance level at that point to enable clear detection.
(c) The design should be such that uniform lux level is maintained considering the
utility of the area which is dependent on the following points and is to be decided
by its previous history and the environment:
• Crime status of area
• Nature of site (Business, malls, restaurants)
• Degree of obstruction (Landscape designs, building configuration)
• Ambient brightness of surrounding area.
• Impacts on surrounding areas (stray light from security lighting trespass)
(d) In controlled sites, public spaces, important places, the illumination level for
different areas may be maintained as per Table No 4 in Section 1 of part 8
(building services) of the National building Code.
(e) Ught Controls: These should be of timer clock, photo control, dimmers and motion
detectors. Ughting control should be energized lighting when ambient natural light
level is less than 1.6 times the minimum horizontal security luminance value or 15
lux whichever is higher.
(f) For fac;ade lighting the illumination level on building faces should be kept as
required with an arrangement to increase or reduce this whenever essential on the
situation and vital nature of the building. There should be rotating search/flood
lights for very important buildings.
(g) For vital buildings on the compound wall or on the fence, electrical fenCing of lower
voltage(below 30 volts) can be proposed with sensor arrangement.
(h) In addition to the main supply to the license through a transformer and lor a stand
by generating system to fulfill minimum basic requirements in case of failure of the
main supply an invertors or UPS system for the centralized security system & for
access control shall be provided. The generating system and transformer should
preferably be provided outside the building with necessary security and the
electrical cables should be underground/ metallic covered.
Page 5 of9
,-
i
I
-6-
SERIES - I No.: 01'----_-1
DATED: 15TH JANUARY, 2010.
(i) The usual provisions for maintenances of the Power Supply System and luminaries
shall be properly scheduled for periodical serviCing tests, inspections, repairs,
security audits for electrical installations. Etc.
6 Fire requirements :
All provisions of fire in the National Building Code and the existing D.C regulations
shall be complied. In addition the following provision shall be made against fire.
(a) Provisions of automatic dampers to the main fresh air dust at individual floors.
(b) Protection of entire area with sprinkler system.
(c) Provision of micro processor ceased wireless addressable detector system with
connectivity to the nearest Police Station and fire Station including basements and
mezzanine floors.
(d) Florescent signage showing directions of escape routes/staircases.
(e) We risers and sprinkler systems shall always be kept on automation mode.
(f) Provisions of 10/15 Kg capacity water bases mist system 300 bar operating pressure
portable extinguisher near the staircase or lift lobby on every alternate floor.
(g) Cooking below or within the building shall be disallowed and provision only made for
heating with oven, hotplate, tea/coffee machine, etc in the pantry. However, this
restriction shall not apply to star hotels, Hospitals and other buildings with core
functions requiring food service, in which case the kitchen shall be provided with
adequate precautions as directed by the Fire officer and designed for 4 hour fir
resistance. It is preferable to carry/out cooking in a detached building.
(h) Fire retardant coat shall be applied to all combustible partitions.
(i) Provisions of minimum two open able windows shall be made on each face of the
building.
(j) All windows and glazing on outer walls shall be provided with shatter proof protection
film.
(k) In addition any more stringent provisions in existing DC regulations and the guidelines
issued in National Building code Part 4 Fire and Life Safety shall be followed.
7.0 Requirements for quick Evacuation during emergencies:
7.1 Adequate ~~ovision within the building for quick and safe evacuation shall be made in
accordance with the standards of National Building Code including number and width
of exit doors, passages to be used as escape routes, staircase, longitudinal and cross -
aisle and passages in the offices with built up furniture.
7.2 All external cladding shall be provided with shatter proof membranes to the glass walls
and open able shutters at intervals for access to rescue teams and to release air
pressure due to any blast.
7.3 Maps of exit routes shall be displayed at various spots within the building.
Page 6 of9
-7-
SERIES - I No.: 01
DATED: 15TH JANUARY, 2010.
7.4 A separate entry and separate exit are to be provided for each wing of a building
having different activities i.e. Malls, Multiplexes, Offices, etc.
7.5 Emergency light operation on UPS or inverters lasting for 48 hours shall be provided.
7.6 A trained safety squad shall be provided for monitoring quick and safe evacuation in
case of emergency. Every building shall have a building-specific safety manual to be
got approved from Are Officer and Police Department containing the duties &
responsibilities cI various squad members/floor marshals etc.
1.1 The •• . II pp ... isFia*.· sial be made in respect of quick and safe evacuation during
g *s. 7 S tile bUIIfng and within the compound of premises:
MI._ eilrJell: routes case cI emergencies to be provided on the rear side,
... Idr aUd be noon kept cIased and used only during emergencies.
PlvrisicJn af direct outlets fur tal lJuiIdings by way of Skywalks across the open
areas discharging the persons itSide, additional external staircases and fire
escapes etc.
(c) Every tall building should store canvas vertical chutes for vertical descent from
upper floors.
(d) In addition ,any special provision required by Rre Authority shall be made.
8.0 Blast resistant design of buildings.
8.1 the building shall be designed for blast resistance in accordance with the guidelines
given in I.S. 4991-1968.
8.2 The following requirements should be taken into account in planning and design:
(a) Provisions of optimal combination of mass stiffness in the building structure, enough
structural redundancy in the building members strength proportioned as per
capacity design concept consideration of reversal of loading, strong connections,
etc.
(b) The building should be designed with at least one corner/critical column removed,
without collapse. For critical and complex structures, progressive collapse shall be
examined by detailed non-linear and dynamic analysis under the application of blast
loading in order to demonstrate the robustness of the design chosen.
(c) Important building shall not be provided with open stilts. All the exposed columns
shall be armored with 12mm steel plates up to 2m height staring from 15 cm. below
ground level or wrapping of suitable fiber material of equivalent strength to prevent
column collapse when shattered.
The wall facing a direct vehicular approach shall be of R.C.C. 45 cm thick suitably
reinforced.
e) The main grid beams at the first floor level shall be provided with equal
reinforcement at top and bottom to cater to any stress reversal.
thida Ie5S cI stilt members in the ground floor and floors below shall
. hu :e cl 3 hoLr.; as spedfies in I.S. 456.
0XItrf./ -
Page 7 of9
-8-
SERIES - I No.: 01
DATED: 15TH JANUARY, 2010.
(g) The various architectural control shall be so provided that the building is away fro
hub activities. Roads should not lead straight into the building in question. The
number of roads to the building must be minimum Provision for effective entry
control for persons, vehicles and materials, provision of spikes to puncture tyres
preventing inbound vehicles from using outbound lanes, provision of passive and
active barriers etc. shall be made.
(h) The parking lot should be located away from as high rise building with proper entry
control and away from the standoff zone.
(i) Parking under the building and in the basement within its internal courtyard is to be
prohibited to the extent possible and where unavoidable visibility in and out of the
garages must be maximized and entry should be strictly controlled as it is for
approaches /entry in to the building. It shall be ensured that the ramps for the
basement shall not start directly from the front open space of the building.
G) Orientation of the building should be such that walls with glazing are perpendicular
to street side fa91de. Reentrant comers must be avoided must be avoided on the
building exterior.
(k) Provision shall be made for a separate depository room away for the main building
for depositing the personal baggage of visitors.
8.3 The various other provision detailed in the site and building envelope mitigation
measures as per National Building Code of India 2005 or its latest version should also
be given due consideration as may be feasible and applicable for a particular site.
9.0 Other Provisions
9.1 All existing building considered vulnerable to terrorist attack shall also make provision
for compliance with these regulations except those which are not applicable or
feasible or possible to be complied with in the opinion of the Planning Authority or
the Competent Authority of the Police Department. This includes retrofitting as may
be required to comply with these provisions.
9.2 Owners/Occupier of the premises shall have his own security management
administration with trained personnel, execution procedures, fire & evacuation drills,
security audits & a manual containing various requirements and procedures for
security control with properly defining duties and line of control and directions which
shall be got approved from the Police Department.
9.3 Proper monitOring and periodical security audit of S&SS system shall be done and its
report shall be submitted to the Specified Authority of the Police Department.
9.4 The owners/occupies of such specified building shall assist the Police or State
authorities in arranging and carrying out third party security Audit at specified
intervals as directed.
9.S For Hazardous building the provision of D.C. Regulations and the National Building
Code, whichever are more stringent, shall apply. In addition, these special
Regulations, shall also apply to such buildings as may be found feasible and
necessary in the opinion of the Planning Authority and the Competent Authority of
the Police department.
Page 8 of9
-9-
SERIES - I No.: 01
DATED: lS11i JANUARY, 2010.
9.6 i· 5 "'1IIese Secuity Regulations is permissible.
9 .... cd .. 3 copies of approved digital maps of the building with all
......... btiorlS before issue of occupation certificate .
...... file Fighting Equipments, the following devices should be installed.
5 7 " out Door Cameras (CCTV) with proper lighting, Monitors and data
1III!C:crd1ing facility covering all important points esp. Entry/exit, Parking, litterbins
and other critical areas
2. Door Frame Metal Detector (DFMD)
3. Hand Held Metal Detector (HHMD)
4. Search tool kit (Torch, Extension Mirror, Prodder, Screw driver set, Nylon Cord
etc.)
5. Under vehicle search mirrors.
6. Search Lights.
7. X-ray Baggage Scanner
8. Automatic/Manual Barrier/Slide Gate
9. Emergency P.A. System
10. Intercom/Wireless facility at all important pOints.
Apart from these equipments, the following features should also be provided.
1. Stand-off distance
Minimum stand-off of the mall building from the public roads should be
maintained to help in vehicle management during rush hours/any contingency.
2. Security Control Room.
3. Safe Room/cloak Room near the entrance for the deposit of bags.
4. VOice recording capability to monitor threat calls.
5. Minimum litterbins to be kept and must be clearly covered and monitored by CCTV
systems.
6. All the staffs should be provided with Bic-metric identity card to avoid unauthorized
access to critical areas.
7. T,:;ey should prepare CMP and conduct period mock drills.
This Notification will take effect from the date of publication in the Official Gazette of
Daman and Diu.
By Order and in the name of the
Administrator, DD and D&NH
Sd/-
Joint Secretary (UD)
Daman & Diu
{Government Printing Press, Daman. 0112010 250.}
{ Price Rs. 3.00}
Page 9 of9
dm;nistration Of Daman and Diu
Urban Development Department
Daman
No.ATP /DMN/Slum/3145/2012/ SII
OFFICE MEMORANDUM
Dated: I j /10/2012
The Parliamentary Standing Committee on Urban Development(2007-08)
presentee t~irty second report in 14'" Lok Sabha containing recommendations at Serial
0.19 \3';' report) in paragraph 0.4.26(32"" Report) on vertical development of Slums.
The Committee in its recommendations mentioned that with rapid pace of urbanization,
land space in cities has been constantly shrinking and the horizon tal development of slums
devoid of basic facilities/amenities, open spaces, proper roads etc. The Committee conveyed
its recommendation to the Ministry of Housing & Urban Poverty Alleviation, GOI and urged
to adop t approach of vertical development of slums areas with provisions of all basic
amenities. Accordingly, the Ministry of HUPA has informed vide its letter No.G-20011
/13/2 007-BSUP/JNNU RM(Vol.!l) dated 16.07.2010 to this UT Administration to take into
accou nt tl.e approach of ve rtical development for the Slum up gradation projects under
IHSDP am: projects of housing schemes for EWS as recommended by the Parliamentary
Standing Committee.
In this context, it is hereby directed that all agendes including MuniCipalities in
UT of Daman and Diu implementing the slum up gradation projects under IHSDP or any
other housi ng scheme for EWS should explore the feasibility of vertical development of
slums areas with provisions of all basic amenities, open space, proper roads etc. and should
be im plemented in letter and spirit within the norms of DC's Rules.
This is issued with the approval of the Administrator of Daman and Diu and DNH
vide diary7984 dated17.10.2012.
Copy to:
\~ ~ J(
\\ \ )~:: ~ :,.\-, o-') ~, 'l-----=.--
(p).Parmar)
Deputy Secretary(UD)
All concerned Agencies including OIDC implementing the Slums up gradation
programmes and Housing Schemes of EWS in UT of Daman and Diu for compliance.