G.S.R. 325(E). - Environment (Protection) (Fourth Amendment) Rules, 2014.
Rules made under The Environment (Protection) Act, 1986
- Made under: The Environment (Protection) Act, 1986
This text is shown as one document.
Full text
To Fo TeTo-33004/! REGD. NO. D. L.-33004/99
NRA £ A5UA
The Gazette of India
EXTRAORDINARY
o [I—@ve 3—3u-Tug (i)
PART II—Section 3—Sub-section (i)
TR ¥yt
PUBLISHED BY AUTHORITY
6. 252] & feeelt, guEw, wE 7, 2014/39T0@ 17, 1936
No. 252] NEW DELHI, WEDNESDAY, MAY 7, 2014/VAISAKHA 17, 1936
TR 3R A wEe
ST
«$ fooehl, 7 @€ 2014
11,325 (31). —DHETT TRHIR, TATIROT (EeT) SIfAFEE, 1086 (1986 BT 20) W € 6 MY € 25 FRT
TeT WfdkAl BT WA S gy, TATaReT (W) e, 1086 @1 3R weied we @ fov fefeiea frem gt g
1. (1) 7 Frdt & wfera T wafawor (wero) (@ wees) |, 2014 © |
(2) T IoTTA F UBTIT W ARG B T B |
2. Tatawor (dve) FE, 1986 BT ST 1 H, ‘Wie SR Wi ATeAfie ST wafta oH wend 8
S S wafea vfafedl & o w, frfaiad &9 s o afafear wit s, seifd -
Bl sEm Terftex D
(1) @) (3) (a)
“g EScE S ®. Iu AFD (fhatate)
et e T 9@ Sl A Gal W &, | e o
Forferara T BeEey (Frar /e o diex ) aa W
il
AR B IsS (SOy) 200
HCI (a7 firze) 35
sEfrr (NH ;) 30
FARA(Cly) 15
fewwr : it franfafa & aifafs, 8T SRR @I R fHAT T E, T S AT AT B G BH A
W A AR I s Harg B R T
. afe:oma aHw
<igoT < fferm/eer (R /eft) &, fga, qowe, &1
SR aiey wher & fyar
YoId # @g@ e we § | 9 w R 5
aga forg
dLTa (pH) 6.0 9 85 553 9.0 553 9.0
Freifae wo 100 - 200
1913 GI/2014 @
THE GAZETTE OF INDIA : EXTRAORDINARY [PART II—SEC. 3(i)]
YT WA sTRio #-BOD 30 100 100
(3 &, 27°C)
XA FmaRiteH 7 (COD) 250 250 -
N @& w0 ¥ S Tggio 50 50 —
A WE el & A 5°C I it -
&
3T (@99 7P 400 — —
R (Hg) 0.01 0.01 —
Soere B (Cr'e) 0.1 10 —
Fa Hiaw (Cr) 2.0 20 —
amr (Cu) 2.0 3.0 -
W (Zn) 5.0 15.0 -
Fferer (Ni) 3.0 5.0 -
= (Pb) 0.1 20 -
et (Mn) 2.0 20 -
wefran (Cd) 02 20 —
TS (C) 1000 - -
wee (SO, 1000 - —
CHsOH @& @ # fpiferas #ifira 1.0 50 -
T 3R A 10.0 10.0 -
IETR e @RI @ agA | 100% dSema 7 — —
1:8 @ W™ 96 Tk & wEE
90% ST sraera
* qRITOREs TR M. TR, : 6582 : 1971 B IR AANCKT fbaT TG |
fewror ;
(0] T g T@E W A ML & W afEemn & g w e (Froer) 31 @
&, gt @ Jor @ oy e vguer Frimm a6 & R d, aiR, ser ar fEdd &
A e @ R B WS & A @A @ sravas g6 | T 3k | IS SR B Wie
@& forg 3f f 3R & HH W BH A A AR A e S@H T S | S gy
R BT MHR G @IT F g vfy FeeR & oy ve qranndt \iE g 98 @t @y S |
(ii) AR IRE G ST I o TR @G I@d W HIT FARES R Aehe F AD
@r B | wft, 9 w R @ R e & e (Fuer) woaee $ w0 § wRgs ot
A A FE e § FdREs B Arsar 600 e R @ ofvw A arft ok dfemw
ST B < (SAR) 26 3 o & A |
(iii) wfe ar srifaT afEma o <t # W AR I werw fmar stom Ry e @
WU HIRA T A
1. B TG WA B (Y Ao AD
T T® ST Hhal T AT | O Th AT Hhal q T
3, aigor e w1 ffere | @, fre i sty
B a6 i
il
e uaret 50 30 I7 IfE® (300 AX B
Sk @ TR @ R
HCI (s fire) 50 30
SO, 200 30
DI AT 100 e sfrra
A IAD B 20 30
P SR S GG 0.1 ng TEQ/mmm=1 8 He
AR
Sb+As+Pb+Cr+Co+Cu+ 15 2%e
Mn+Ni+V+Cd+Th+Hg ik S7%
s
[0 [1-8vs 33)] IR HT TSI 2 STHHERT 3
i. A AR 5T T A DT 119 SRS @ SR I SR U S fHar o |
ii. S K # B SESTaRIES B AR 7% § & @ e |
iii. Frarer s @t Rafy # gelifores wRfT® smfie oo # 19, 1 &9 & i,
foam TR weligRn W (gl wEwd awR) # 9 gt or 5@ ae feeme e
T @ WS AR # 850 +25°C IR AdHSd HHEIE AR F 950°C BT FATH A
AT S A o AR Ihet dEe AR A SR A IS J & A g |
a
THE TR AR AT AR Awewd e g @ gt o 3w we feemsT fmar
TG A R TR F 950°C B AT AT IR S A0S forads drer i R
A JFS J HH AG AW
iv. Fraw st @ Rufy # geifrcs arf® sfie, aw § 19 & fds & o daa
oo T wrftaRer ET # S aT AR R Se sik | it o 59 av e
o s qfes e R # 850 +25°C SR IS T TR F 1100°C BT AT AHA
TART O S RS A1 Ahed wrEee TRk # A SR e <1 e BF T8 e |
v. AEBROT WIF B GG HED B Y O AGG §, SABT UG Hax b w0 F E
T smem |
vi. DR T B U A, SR T SR AT D AR TS ar S
M e st wefiawr w@ § o Ets s (TOC) e 3% 3 &7 @ ok s siv
I B ARG G FT A BT Y AR 5% F G Q| et & A F el ww siv
ST BT GaRT WRHATHROT T S |
Vii. AR W G Y Fef @ g g dw dex v < |
a. weftew Wi @ g aftoma wme
fewror ;
[0)] w3k T gers See ¥ SO ATHE T gE A A ST Veqw & W J
TEIAT ST R FHT AT TR W A F Sferaa afEa et @ gy A s |
(ii) T germg s # g giad @it (TDS) @t A7 &ed o # ot giend woit ot 71 &
TR 1000 FfemmA/ceR ¥ oifad T &f |
. ast o
fewror ;
@M Ul A BT AGD A SRYA T GAS ST B 0 frery & g gl 7@ & e
(ii) qui W BT q & 10 e (B @ o) BT IwEw el & ga. il wa A e &
T Y ST AH F @R ST [
[W®1.3. &-15017/ 14/ 2009~ 4l €=, |
<. ARG §, FeAEDR
Roqur : 7o From kA & WUSTTT F BT G 844 (3), TG 19 TdER, 1986 H WHTIIG fHY MY o Y FewrwEq
SfoRgaT WEA® DI 433 (o), TR 18 WA, 1987; WLALFL 01(3), W@ 1 wWad, 2010;
DL 61(3), TEE 5 wxAd, 2010 ; WL 485(3), TIW@ o TH, 2010; WL 608(3), IR
21 g, 2010; WLHLA. 739(37), ard@ o RicaR, 2010; WLHLF. 809(37), AW 4 IE@TER, 2010; ALHLF
215(3), TR 15 AT, 2011; WS 221(3), TRE 18 A, 2011; WL.HIF. 354(37), IR@ 2 7L, 2011;
WHLEA. 424 (), TG 1 TF, 2011 5 ALBLE. 446(3), TG 13 T, 2011 ; WHLF 152(37), TE@ 16 AT,
2012; W@ 266 (37), ARG 30 A, 2012,; WLHF 277 (), AEE@ 31 A 2012; WHLEA 820(30),
TR 9 TG, 2012; WHLE 176(3), TE@ 18 A, 2013; VB, 535(37), AW 7 I, 2013; @B
771(@),TE 11 REeR, 2013; wef 2@), @@ 2 wWad, 2014; WHLE 229(e), dRRE
28 AT, 2014; 3R WM. 232(37), TEI@ 31 A, 2014 FW FAMRT Y T |
4 THE GAZETTE OF INDIA : EXTRAORDINARY [PART II—SEC. 3(i)]
MINISTRY OF ENVIRONME] AND FORE!
NOTIFICATION
New Delhi, the 7th May, 2014
G.S.R. 325(E).— In exercise of the powers conferred by sections 6 and 25 of the Environment
(Protection) Act, 1986 (29 of 1986), the Central Government hereby makes the following rules further to
amend the Environment (Protection) Rules, 1986, namely:-
1. (1) These rules may be called the Environment (Protection) (Fourth Amendment) Rules, 2014.
(2) They shall come into force on the date of their publication in the Official Gazette.
2. In the Environment (Protection) Rules, 1986, in Schedule I, for serial number 8 relating to ‘Dye and
Dye Intermediate Industry’ and entries relating thereto, the following serial number and entries shall be
substituted, namely :-
S.No. | Industry Parameter Standard
@ 2) 3) @)
3 Dye and Dye A.Emission Standards (Process)
Intermediate Limiting concentration in milligramme/Normal cubic metre
Industry (mg/Nm’), unless otherwise stated
Oxides of Sulphur ( SO,) 200
HCI (Acid Mist) 35
Ammonia (NH,) 30
Chlorine (Cly) 15
Note: All process vents shall have chimney height of atleast two metres above the shed or
building where equipment is installed.
B. Effluent Standards
Limiting concentration not to exceed in milligramme/litre (mg/1),
except for pH, Temperature, Colour and Bioassay.
disposal in marine disposal | on land for
surface water irrigation
pH 601085 55-90 55-9.0
Suspended Solids 100 B 200
Biochemical Oxygen Demand - 30 100 100
BOD (3 days, 27°C)
Chemical Oxygen Demand 250 250 E
(COD)
Ammonical Nitrogen as N 50 50 -
Temperature shall not exceed 5C above the -
receiving water
Colour (Hazen unit) 400 - -
Mercury (Hg) 0.01 0.01 -
Hexavalent Chromium (Cr'™) 0.1 1.0 -
Total Chromium (Cr) 20 20 -
Copper (Cu) 20 30 -
Zinc (Zn) 50 150 -
Nickel (Ni) 30 50 -
Lead (Pb) 0.1 20 -
Manganese (Mn) 20 20 -
Cadmium (Cd) 02 20 -
Chloride (CI') 1000 - -
Sulphate(S0,%) 1000 - -
Phenolic Compounds as 1.0 50 B
CeHsOH
[0 [1-8vs 33)] IR HT TSI 2 STHHERT
Oil & Grease 100 100 10.0
90% survival of
Bio-assay Test (with 1:8 Test animals
dilution of effluents) after 96 hours* in - -
100% effluent
* The Bioassay test shall be conducted as per IS: 6582: 1971.
Note:
() In case of disposal of cffluent on land by industry directly or through a CETP, the industry or,
CETP as the case may be, shall be required to install piezometers for monitoring of groundwater.
Atleast, two piezometers for three hectares shall be installed for a plot size above 10 hectares with a
minimum of 16 piezometers. It shall be one per hectare within a minimum of six piezometers for a plot
of size smaller than 10 hectares, in consultation with the concerned State Pollution Control Board for
siting of piezometers.
(ii) The standards for Chloride and Sulphate shall be applicable only for discharge of treated effluent
into inland surface water courses. However, when discharged on land for irrigation, the norms for
Chloride shall not be more than 600 mg/l over and above the contents of raw water and the Sodium
Absorption Ratio (SAR) shall not exceed 26.
(ili) Treated /untreated cffluent shall be stored in holding tank(s) in such a manner which would not
cause pollution of groundwater.
C. Emission Standards for Captive Incinerator
Limiting concentration in | Sampling Duration in minutes
mg/Nm’, unless otherwise stated | unless otherwise stated
Paticulate Matter 50 30 or more (for sampling of 300
litres of emission)
HCI (Acid Mist) 50 30
50, 200 30
Carbon Monoxide 100 daily average
Total Organic_Carbon 20 30
Total Dioxins 0.1 ng TEQ/Nm 8 hours
And Furans
Sb+As+Pb+Cr+Co+Cu+ L5 2 hours
Mn+Ni+V+Cd+Th+Hg and
their compounds
Note:
i, All monitored values shall be corrected to 11% oxygen on dry basis.
ii. The CO, concentration in tail gas shall not be less than 7%.
iii. In case, halogenated organic waste is less than 1% by weight in input waste,
all the facilities in twin chamber incinerator shall be designed so as to achieve a
minimum temperature of 850 + 25°C in primary chamber and 950°C in secondary
combustion chamber and with a gas residence time in secondary combustion chamber
not less than two seconds.
or
All the facilities in single chamber incinerator for gaseous hazardous waste shall be
designed so as to achieve a minimum temperature of 950 °C in the combustion chamber
with a gas residence time not less than two seconds.
iv. In case halogenated organic waste is more than 1% by weight in input waste, waste shall be
incinerated only in twin chamber incincrators and all the facilities shall be designed to achieve a
minimum temperature of 850 25°C in primary chamber and 1100°C in secondary combustion chamber
with a gas residence time in secondary combustion chamber not less than two seconds.
v. Scrubber meant for scrubbing emissions from incinerator shall not be used as quencher.
vi. Incineration plants shall be operated, (i.c., combustion chambers) with such temperature, retention
time and turbulence, as to achieve Total Organic Carbon (TOC) content in the incineration ash and
residue less than 3%, and the loss on ignition for ash and residue is less than 5% of the dry weight. In
case of non-conformity, ash and residue, as the case may be shall be re-incinerated.
6 THE GAZETTE OF INDIA : EXTRAORDINARY [PART II—SEC. 3(i)]
Vii. The incinerator shall have a chimney of at least thirty metres height.
D. Effluent Standards for Incinerator
Note:
(i) Effluent from scrubber (s) and floor washing shall flow through closed conduit or pipe network
and be treated to comply with the effluent standards mention at ‘B’ above.
(i) The built up in Total Dissolved Soilds (TDS) in wastewater of floor washings shall not exceed
1000 mg/l over and above the TDS of raw water used.
E. Stormwater
Note:
(i) Stormwater shall not be allowed to mix with scrubber water and/or floor washings.
(ii) Stormwater shall be channelized through separate drains passing through a HDPE lined pit having
holding capacity of 10 minutes (hourly average) of rainfall.”.
[F. No. Q-15017/14/2009-CPW]
Dr. RASHID HASAN, Advisor
Note: - The principal rules were published in the Gazette of India vide number S.O. 844 (E), dated
the 19th November, 1986 and subsequently amended vide notification numbers S.O. 433 (E), dated the
18th April 1987; G.S.R. 01 (E), dated the 1st January, 2010; G.S.R, 61 (E), dated the 5th February, 2010;
G.S.R. 485 (E), dated the 9th June, 2010; G.S.R. 608 (E) ,dated the 21st July, 2010; G.S.R. 739 (E), dated
the 9th September, 2010; G.S.R. 809(E), dated, the 4th October, 2010, G.S.R. 215 (E), dated the 15th March,
2011; G.S.R. 221(E), dated the 18th March, 2011; G.S.R. 354 (E), dated the 2nd May, 2011; G.S.R. 424 (E),
dated the 1st June, 2011; G.S.R. 446 (E), dated the 13th June, 2011; G.S.R. 152 (E), dated the 16th March,
2012; G.S.R. 266(E), dated the 30th March, 2012; G.S.R. 277 (E); dated the 31st March, 2012; G.S.R. 820(E),
dated the 9th November, 2012; G.S.R. 176(E), dated the 18th March, 2013; G.S.R. 535(E), dated the
7th August, 2013, G.S.R. 771(E), dated the 11th December, 2013; G.S.R. 2(E), dated the 2nd January, 2014,
G.S.R. 229(E), dated the 28th March, 2014 and G.S.R. 232(E), dated the 31st March, 2014.
Printed by the Manager, Government of India Press, Ring Road, Mayapuri, New Delhi-110064
and Published by the Controller of Publications, Delhi-110054.