Legal Metrology General Rules, 2011
Rules made under The Legal Metrology Act, 2009
- Made under: The Legal Metrology Act, 2009
This text is shown as one document.
Full text
_L "._._ .. _.~. , _ ....• _ .•. '. __ ._._, ' •.....•. ,~" , '0. _ •••• , .'_ ••.•, ., ....... ,..:_
318 'THE GAZETTE OF'lNDIA: EXTRAORDINARY [PARTII-SEC. 3(i)]
MINISTRY OF -CONSuMER AFFAIRS, FOOD AND
5JBllC'DISTRIBUTION
(DEPARTMENT,OFCONSUMERAFFAIRS)
N011FICATION
New~DelhVthe,7th February 2011
G.S.R. 7.1(E).- In exercise of the powers
conferred by sub-section (1) read with Clauses (c),
(f), (h), (i) and.:(~)of sub-section (2) of section 52 of
The LegalMetrology Act 2009,,(Lof 2010), the Central
Government heret?Y.makes;thefOllowing rules, namely
CHAPTER I
.PREUMlNARY
1.Short title and-commencement
(1) These rules may be called the legal
Metrology (Genert!I),Rules, 2011.
(2) They shall come into force on the lit day of
April, 2011.
2.Definitions
In these rules, unless the context otherwise
requires,-
(a) "ActN means the Legal Metrology Act, 2009
(lot 2010);
(b) "Schedule" means a Schedule appended to
these rules;
(c) "Section" means a Section of the Act;
(d) words and expressions used in these rules
and not defined but defined in the Act shall
have the meanings respectively assigned to
them In the Act.
CHAPTERU
SPECIACATIONSOFSTANDARDSOFWEIGHTS AND
MEASURES
3. Reference standards
(1) Every reference standard weight shall
conform, as regards denomination, material used in
construction, and design, to the speCificationslaiddown
in Part I of First Schedule.
(2) The maxImum permissible error In respect
of any reference standard weight, on verification or
re-verification after adjustment, shall be such as is
spedfied in Part I of First Schedule.
(3) Every reference standard metre bar shall
conform, as regards material used in construction, and
design, to the specifications laid down in Part II of First
Schedule. '
(4) The maximum permissible error in respect
of any reference standard metre bar, on verification or
re-verlfication, shall be such as Is specified in Part IIof
First Schedule.
4. Secondary standards -
(1) Every secondary standard weight shall
conform, as regards denomination, material used In
construction, and design, to the specificationslaiddown
In Part Iof Second Schedule.
(2) The maximum permissible error in respect
of any secondary standard weight, on verification or
re-verlflcatlon after adjustment, shall be such as Is
specified In Part Iof Second Schedule•
(3) Every secondary standard metre bar shall
conform, as regards material used in construction, and
deSign, to the specifications laid dawn in Part II of
Second Schedule.
(4) The maximum permissible error in respect
of any secondary standard metre bar, on verification
or re-verlficatlon, shall be such as Isspecified in Part II
of Second Schedule.
(5) Every secondary standard capacity measure
shall conform, as regards denomination, material used
in construction, and design, to the specifications laid
down In Part IIIof Second Schedule.
(6) The maximum permissIble error in respect
of any secondary standard capacity measure, on
verification or re-verification after adjustment, shall
be such as Is specified in Part IIIof Second Schedule.
5.Working standards
(l) Everyworking standard wetghtshall conform,
as regards denomination, material used in construction,
and design, to the specifications laid down in Part Iof
Third Schedule.
(2) The maximum permissible error in respect
of any workIng standard weight, on verification or re
verification after adjustment, shall be such as Is
specified In Part I of Third Schedule.
(3) Every working standard metre bar shall
conform, as regards material used in construction, and
design, to the specifications laiddown in Part II of third
Schedule.
(4) The maximum permissible error In respect
of any working standard metre bar, on verifICation or
re-verlficatlon, shall be such as Is specified In Part II of
Third Schedule.
(5) Every working standard capadty measure
shall conform, as regards denomination, material used '
in construction, and design, to the specifications laid
down In Part III of Third Schedule.
. -.------~~~----~----------------------~------
• ; ,.,~: ~ .. _- _.... •• ,•.•••• -.• -,.--.-~.- ••• -....... ••• ,-_ - --- -'. -_ ••__ ._ -_,,' .- • • •••• y•••• ~"-" _•• -----:--' '_'''_'- '-"'~-"""---'-"-- ._"_ ••,;..".......~-
['q1T[ n-~ 3(i)] 319
(6) The maximum permissible error In respect
of any working standard capacity measure, on
verification or re-verification after adjustment, shall
be such as is specified in Part II~ofThlrd Schedule.
6. Power to specify any other reference,
secondary or working standard
(1) Any other reference standard, or secondary
standard, or working standard shall conform as regards
the denomination, material used in construction, and
design, to such specifications as the Central
Government may, from time to time, by notifICation,
specify,
(2) The maximum permissible error In relation
to such other reference standard, or secondary
standard, or working standard shall be such as the
Central Government may, from time to time, by
notification, specifyand different maximum permissible
errors may be specified in relation to different types
of reference standards, or secondary standards, or
working standards.
CHAPTERW
SPEOACATIONS OF STANDARD EQUIPMENT
7. Reference standard balances
(1) A set of reference standard balances shall
be maintained at every place where the reference
standard weights are kept for the purpose of
verification of secondary standards.
(2) The number, types and specificationsof such
balances shall be as are spedfied in Part 1of Fourth
Schedule.
(3) Every reference standard balance shall be
verified at least once In six months and shall be
adjusted, if necessary, to make it correct within the
limits of sensitivity and other metrological qualities as
are speclfled In Part I of Fourth Schedule.
s.Secondary standard balances
(1) A set of secondary standard balances shall
be maintained at every place where secondary
standard weights are kept for the purpose of
verification of working standards.
(2) The number, types and specificationsof such
balances sh(!11be as are specified in Part IIof Fourth
Schedule,
(3) Every secondary standard balance shall be
verified at least once In one year and shall be adjusted,
if necessary, to make It correct within the limits of
sensitivity and other metrological qualities as are
specified in Part IIof Fourth Schedule.
9. Working standard balances
(1) A set of working standard balances shall be
maintained at every place where working standard
weights are kept for the purpose of verification of
weights intended to be used for transaction or
protection,
(2) The number, types and specificationsof such
balances shall be as are laid down In Part III of Fourth
Schedule.
(3) Every working standard balance shall be
verified at least once in a year and shall be adjusted,
if necessary, to make it correct within the limits of
sensitivity and other metrological qualities as are
spedfled In Part IIIof Fourth Schedule.
10.Power to specify the standard equipment
The Central Government may, by notification,
specify such other standard eqUipment as it may think
necessary to carry out the provisions of the Act and
every such standard equipment shall conform, as
regards the metrologlca I qua lities, to such
spedfications as the Central Govemment may, in the
same notification or subsequent notification, specify.
CHAPTER IV
WEIGHTS OR MEASURESAND WEIGHING AND
MEASURINGINSlRUMENlS
11.Weights
(1) Save as otherwise provided in these rules,
every weight used or intended to be used-
(a). in any transaction, or
(b) for protection,
shall conform, as regards physical characteristiCS,
configuration, constructional details, materials,
performance, tolerances and suchother details, to the
corresponding specifications laid down for suchweight
in Fifth Schedule.
(2) The maximum permissible error in respect
of such weight shall be such as is specified In Fifth
Schedule,
(3) Nothing in this rule shall apply to the product
of an Industry which is required, by or under any law
for the time being in force, to conform to any other
specifications with regard to the matters spedtted In
sub-rule (1) or sub-rule (2), if, under such law, the
product Is required to conform to the specifications
laid down by the International Organisation of Legal
Metrology with regard to the matters aforesaid,
12. Measures (other than measuring
instruments)
(1) Everymeasure used or intended to be used
for-
(a) any transaction, or
(b) protection,
• __ •• _~ ••••••• ..; •• _ .. __ '-_ __ , .• J ••
320 THE GAZETTE OF INDIA: EXTRAORDINARY [PART II-Soc. 3(i)]
shall contorm.cas. regards physical characteristics,
configuration, constructional detailS, materials,
performance, .tolerances and such other details, to
the corresponding. specifications laid down for such
measure in Sixth Schedule.
(2) The maximum permissible error 'In such
measure shall .be such as is specified in the
corresponding. specifications laid .down for such
. measure in Sixth Schedule.
13. Welghl~g and measuring Instruments
(1) Every.welghlng Instrument usedor intended
to be used-
(a) in any transaction, or
(b) for protection,
shall conform, as regards physical characteristics,
configuration, constructional detatls, materials,
performance, tolerances and such other details, to the
corresponding speCifications laid down for such
weighing instrument 1nSeventh Schedule:
(2) Every measuring instrument used or
Intended to be tlsed-
(a): in anytransactJon, or
(b) for protection,
shall conform, as regards physical characteristics,
configuration, constructronat details, materials,
performance, tolerances and such other details, to the
corresponding spedttcatlons laid down for such
measuring instrument In Eight Schedule.
(3) The maximum permissible error on such
weighing or measuring Instrument shall be such as is
specified in the corresponding specifications laid down
for suchweighing or measuring instrument In Seventh
Schedule or as the case may be in Eighth Schedule.
14. Procedure for carrying out calibration of
vehide tanks, etc.
The procedure for carrying out calibration of
vehicle tanks, etc. shall be as is specified In Ninth
Schedule.
CHAPTERV
IMPORTOFWEIGHTSAND MEASURES
15. Registration of Importer
(1) Every manufacturer or dealer of weight or
measurewho Intends to Import any weight or measure
shall apply to the Director, through the Controller of
the State in which he carries on such business, for
registration of his name as importer In the form
specified in Tenth Schedule.
(2) Every application received by the Controller
under sub-rule (1) shall be forwarded by him to the
Director with a report as to the antecedents and
technical capabilities of the applicant.
(3) Nothing in this rule shall take away or abridge
the right of any person referred to in sub-rule (2) to
carry on the business of importing of any weight or
measure until he has been informed by the Director In
wfitlng that he cannot be registered as an Importer,
and on receipt of such letter he shall stop forthwith
the Import of any weight or measure:
PROVIDEDthat registration of a person carrying
on, at the commencement of these rules, the business
of importing weights or measures shall not be refused
except after giving him a reasonable opportunity of
showing cause against the proposed action.
(4) Every application for the. registration of an
importer shall be submitted to the Director, In the
manner aforesaid, together with the fee specnled In
Twelfth Schedule, at least one month before the date
on which Import is proposed to be made.
(5) The registration of a person as an importer
shall remain effective for a period of five years from
the date of such registration.
(6) On the expiry at the period of registration as
an importer, the Director may, on the application of
the registered importer and on payment of the
prescribed fee, renew registration for a like period.
(7) The registration or renewal of the registration
of a person as an importer may be suspended or
revoked before the expiry of the period of validity
thereof, If the Director is satisfied after an inquiry, and
after giving to the person concerned a reasonable
opportunity of being heard, that any statement made
by such person in the application for registration or
renewal of registration was false or incorrect In
material particulars or that such person has
contravened any provision of the Act or rules made
there under or any term or condition of such
registration.
16. Conditions, etc. for manufacture of aweight
or measure exduslvely for export
(1) The provisions of this rule shall apply to
weights or measures which are made or manufactured
exclusively for the purpose of export.
(2) No non-standard weight or measure shall
be made or manufactured by any person unless he
hasobtained the previous permission from the Central
Govemment.
(3) Every person intending to manutacture any
non-standard weight or measure for the purpose of
export shall make an application for permission to the
Central Government on payment of a fee of rupees
five hundred for such permission authorising him to
manufacture suchweight or measure and shall in such
application Indicate-
(~II-~ 3(0] • 321
(a) his name and full address;
(b) location of the factory in which such weight
or measure is proposed to be manufactured;
(c) description of weight or measure proposed
to be manufactured;
(d) documentary or other evidenceindicatingthe
existence of a firm contract for the export
aforesaid or where there is no such firm
contract for export, documentary or other
evidence Indicating that there Is likely to be
a demand for the export of non-standard
weight or measure.
(4) The CentralGovernment shall, If It issatisfied
from the documentary or other evidence produced by
the applicant or otherwise that the applicant Intends
to manufacture non-standard weight or measure for
export, grant the permission authorising him to
manufacture such weight or measure:
Provided that the Central Government may, if it
Is satisfied that the applicant has contravened any of
terms and conditions of the permiSSionor that weights
or measuresmanufactured by the applicanthavefourd
their way i!lto the Indian market or that the applicant
had made any statement in his application for the
permiSSionwhich Is false In material particulars or he
had concealed some material particulars, cancel the
permission:
Provided Further that no permiSSion shall be
cancelled except after giving to the applicant a
reasonable opportunity of shOWingcauseagainst the
proposed action.
(5) Every permission granted under sub-rule
(4) shall remain valid for a period of one year and
shall be renewed for a like period on payment of a
like fee unlessthe Central Government is satisfied that
the applicant hasmade any statement in hisapplication
which is false In material particulars or that he had
concealed some material particulars or had
contravened any provision of the Act or any rulemade
there under:
Provided that no order for the refusal to renew
a licence shall be made by the Central Government
except after giving the applicant a reasonable
opportunity of showing cause against the proposed
action.
(6) Every person who is granted permission
under this ruleshall submit to the CentralGovernment,
at the end of the calendar year, a statement as to the
quantity of the non-standard weights and measures
exported by him and the particulars of the person to
whom such export has been made.
17. Prohibition on sale ofnon~standard weight
or measure within the country
No non-standard weight or measure made or
manufactured exclusively for export shall be sold or
otherwise distributed within the territory of India.
18. Maintenance of record In relation to nen-
standard weight or measure .
Every person who makes or manufactures any
non-standard weight or measure for export shall
maintain a monthly record of the number of such non
standard weIghts or measures manufactured by him,
. number of weights or measures already exported by
him, and number riweights or measures in stock or
under production. The record so maintained shall be
open to Inspection by any officer authorised by the
Central Government in this behalf.
19. Samplecheddng of weIght and measure
(1) Standard weights or measures which are
intended for export shall not ordinarily require any
verification and stamping, but If the party to whom
the export Isto be made so requires,a samplechecking
of such weight or measure shall be made by such
agencyas the Central Government may specify in this
behalf, and thereupon the agency so specified shall,
after checking the weight or measure, issue a
certificate Indicating whether or not such weight or
measure conforms to the requlr~ments of the Act andtne rules made there under.
(2) The weight or measure to be checked as
sample under this rule shall be selected at random
and proper records shall be maintained with regard
to the sample checking so made.
(3) The Central Government shall, while
specifying the agency for checking the weight or
measure, ensure that the agency completes the
checking well In time so that the export of the weight
or measure Is not delayed by reasonof suchchecking.
20. Checking of non~standard weights and
measures sample which are to be exported
(1) Non-standard weight or measure, which Is
,made or manufactured exclusively for export, shall
not ordinarily require any verification and stamping,
but if the party to whom the export is to be made so
requires,a samplecheckingof suchweight or measure
shall be made by such agency as the Central
~vemment may specly in this behalf; and thereupon
the agency sospecffiedshall, after checkingthe weight
or measure, Issuea certificate Indicating whether or
not such weight or measure conforms to the
specifications given by the party to whom the export
. is to be made or, where the party aforesaid has not
givenany specification,whether the weight or measure
conforms to the specifications laid down by the
manufacturer.
~----'-- _-_ - __..I__.•._--
..
322 THE GAZETTE OF INDIA: EXTRAORDINARY [PARTIl-SEc. 3(i)]
. (2) The weight or measure to 'be checked as
sample under this rule shall be selected at random
and proper records shall be maintained with regard
to the sample checking so made.
(3) The fee for checking of any non-standard
weight or measure shall be--
(i) if it Is similar to ,any standard weight or
measure, equal to the fee leviable for the
verification and stamping of such standard
weight-or:measure; and
(ii) where such.non-standardweight or measure
is not 'similar to any standard weight or
measure, the Central Government may
speclty such amount as fees as ls .
commensurate with the labour Involved in
checklng the non-standard weight or
measure.
(4) The Central Government shall, while
specifying the agency for checking the non-standard
weight or measure, ensure that the agencycompletes
the checking well In time so that the export of such
weight or measure Is not delayed by reason of such
checking.
CHAPTER VI
NON-STANDARDWEIGIiT ORMEASURETO BEUSED
FORsaENTIFIC INVESTIGATIONORRESEARCH
21. Permission to get manufactured non
standard weight or measure for scientific
Investigation or research
Where the manufacture of any non-standard
weight or measure Is needed exclusively for the
purpose of SCientific Investigation or research, the
personneedingsuchnon-standard weight or measure
shall make an application to the Central Government
for permission to get such non-standard weight or
measure manufactured and on receipt of such
application, If the Central Government Issatisfied that
the manufacture of such' non-standard weight or
measure is needed for the purpose aforesaid, it may
authorisethe applicant to get the non-standard weight
. or measure needed by him manufactured by such
manufacturer as he may think fit, and thereupon, it
shall be lawful for such manufacturer to manufacture
the saidnon-standardweight or measure Inaccordance
with the Specificationsgiven by the applicant:
<'. •
Explanation: For the purpose of this rule, a non
standard weight or measure means a weight or
measurewhich Is, or Isproposed to be, manufactured
In a~prdance with any unit of weight or measure,
other.than standard unit of weight of measure
specified by or under the Act... ..:,,' .
CHAPTER VII
MISCELLANEOUS
22. The manner of disposal of goods seized
under this Act/rule
(1) Where any goods seized under sub
section (3) of Section 15 are subject to speedy or
natural decay, the Director or any person authorised
by him or Co~troller and other LegalMetrologyOffIcers
in this behalf shall have the goods weighed or
measured on a verified w.eighing or measuring
instrument available with him or near the place of
seizure and enter the actual weight or measure of the
goods In a form specified by the Director for this
purpose and shall obtain the signature of the trader
or his agent or such other person who hascommitted
the offence. The goods in question shall, after such
weighing or measuring is returned to the trader or
the purchaser as the case may be:
PROVIDEDthat if the trader or his agent or the
other person(who hascommitted the offence) refuses
to sign the form, the Director or the personauthorised
by him In this behalf shall obtain the signature of not
less than two persons present at the time of such
refusal by the trader or his agent or other person.
(2) Where the goods seized under sub
section(1) are contained in a packageand the package
is false or does not conform to the provisions of the
Act or any rules made there under and the goods In
such package are subject to speedy or natural decay,
the Director or any person authorised by him or
Controller 81'\dother Legal Metrology Officers in this
behalf, so far as may be, may dispose of the goods In
such package in accordance with the provisions of
sub-rule (1).
(3) Where the goods seized under sub-rule (1)
are not subject to speedy or natural decay, the Director
or any person authorised by him or Controller and
other LegalMetrology Officers Inthis behalfmay retain
the packagefor the purpose of prosecution under this
Act after giving the trader or his agent or the other
person (who has committed the offence) a notice of
such seizure.
23. Time within which unverified weight and
measure to be verified and stamped
No unverified weight or measure, seized under
sub-section (3) of Section 15, shall be forfeited if the
person, from whom such weight or measure was
.seized, agrees to get the same verified and stamped
within a period of ten days or such extended period
from the date of such seizure; and for this purpose,
the person making the seizure of such weight or
measure shall afford a reasonable opportunity by
------_ __,- ----------:--------:-~--
[qJTT II-'~U6 3( i) ] 323
returning suchweight or measure excruslvely for the
verification and stamping.
24. Register and reports to be maintained by
persons referred to In Section 17 of the Act
(1) Every person referred to in sub-section (1)
of Section 17 shall maintain a register In the
appropriate form set out In Eleventh Schedule.
(2) Notwithstanding anything contained In sub
rule (1), if the Director Is of the opinion that haVing
regard to the nature or volume of the businesscarried
on by any maker, manufacturer, dealer or repairer, it
Is necessary to do so, he may, by order, exempt any
such maker,manufacturer, dealer or repairer from the
operation of that sub-rule. - .
25. Scale of fee
The scale of fees to be collected for the service
specified in column (2) of Twelfth Schedule shall be
at the rate specified In column 3of the said Schedule.
26.Useofregfonallanguages -
Any legend or denomination specified in any
Schedule to these rules, which is required to be
Indicated on any weight or measure in English, or in
Devanagri script, may also be indicated (In addition to
English or Devanagrl) on such weight or measure in
such regional language as the manufacturer may
consider to be practicable.
27. Periodical verification. of weights or
measures-
(1) Every weight or measure used or Intended
to be used in any transaction or for protection of living
beings or things In clause (k) of Section 2 shall be
verified and stamped by the legal Metrology Officer
in the State in which suchweight or measure is put to
use and shall be re-verlfled and stamped at periodical
Intervals.
(2) There-verlflcation shall be carried out on
the completion of a period of,-
(a) twenty four months for all weights, capadty
measures, length measures, tape, beam
scale and counter machine,
(b) sixty months for storage tanks, and
(c) twelve months for all weight or measure
includIng tank lorry other than that
mentioned In clauses (a) & (b).
(3) Notwithstanding anything contaIned in sub
rule (2) every weight or measure which has been
verified and stamped In Situ shall, if it is dIsmantled
and re-installed before the date on which the
verification falls due shall be duly re-verlfled and
stamped, before being put into use.
(4) NotwIthstanding anything contained in sub
rule (1) every weight or measure which has been
verified and stamped shall, If It Is repaired before the
date on which the verification falls due shall be duly
re-verlfled and stamped before being put into use.
28.Qualifications of Legal Metrology Officer
(1) No person shall be appoInted as Legal
Metrology Officer unless he -
(a) Is a graduate of a recognized university In
Science(with physics asoneof the subjects),
tech nology or engineering or holds a
recognizeddiploma Inengineeringwith three
years profeSsional experience; and
(b) is able to speak, read and write the regional
language of the State.
(2) Nothing in sub-rule (1) shall apply to offldals
who have been working as Legal Metrology Officer
and are also eligible for promotion to the next higher
grade of legal Metrology OffIcer on the date of
commencement of these rules.
(3) The person appointed to the post of Legal
Metrology Officer shall have to successfully complete _
the basictraining course at the Indian Institute of Legal
Metrology, Ranchi before his posting.
(4) The Central Government may, In
conSideration of the practical difficulties faced by the
State Government and on its recommendation, relax
the qualification specified in sub-rule (1) for the post
of legal Metrology Officers for that State.
29. Nomination of Director bya Company under
the Act
Every company shall inform the Director (legal
. Metrology) or the concerned Controller or his
authorized officer, by notice in duplicate, in the format
specified In thirteenth Schedule containing the name
and address of its Director after obtaining his consent
in writing, who has been nominated by the company
_under sub-section (2) of Section 49 to be in-charge of
and be responsible for the conduct of businessof the
company or any establishment, branchor unit thereof.
30. Repeal and savings
(1) The Standards of Weights and Measures
(General) Rules, 1987 (herein under referred to as
the said rules) are hereby repealed.
Provided that such repeal shall not affect:
(CI) the previous operations of the said rules or
anything done or omitted to be done or
suffered therein; or
(b) any right, privilege, obligation or liability
Clcqulred,accrued or incurred under the said
rules; or
--- -'1". --4--- ~ .- . -- -"~~---,--.-------- - -
324 THE.GAZETTE OF INDIA: EXTRAORDINARY [PARTU-SEC. 3(i)]
(c) any penalty, forfeiture or punishment
incurred in respect of arw:offence committed
against the said.rules; or
(d) any investigation, legal proceedings or
remedy in respect of .any such right,
privilege, obligation, liability, penalty,
forfeiture or-punishment as aforesaid.
And any such :investigation, legal
proceeCIil"!gsor remedy may be Instituted,
continued or enforced and any such penalty,
forfeiture .or 'Punishment may be Imposed
as if the said rules had not been rescinded.
(2) Notwithstanding such repeal anything done
or any action taken or purported to have been done or
taken indudlng approval of letter, exemption granted,
fees collected, any adjudication, enquiry or
investigation commenced, license and registration of
menutecturers, dealers, importers of weights and
measures, non-standard weights and measures or
show cause notloe, dedslon, detenninatfon, approval,
authorisation Issued,given or done under the said rules
shall.if in force at the commencement of the said rules
continue to be in force and have effect as If Issued,
given or done under the corresponding provisions of
these rules.
(3) The provlslons of these rules shall apply to
any application made to the Central Government or as
the casemay be the State Government under the said
rules for licence, registration of manufacturers,
importers, dealers, repairers of weights and measures
pending at the commencement of these rules and to
any proceedings consequent thereon and to any
registration granted In pursuance thereof.
(4) Any legal proceeding pending In any court
under the said rules et the commencement of these
rules may be continued In that court as If these rules
had not been framed.
(5) Any appeal preferred to the Central
Government or as the case may be the State
Government under the SC!I1d rules and pending shall be
deemed to have beer. made under the corresponding
provisions of these rules.
INDEXOFSOtEDULE OFntE LEGALMETROLOGY
(GEN~RAL) RULES,2011
FIRSTSOtEDULE
PARTI
PARTII
Reference Standard Weights
Reference Standard Metre Bar
SECONDSOtEDULE
Secondary Standard Weights
Secondary Standard Metre Bar
Secondary Standard Capacity
Measures
PARTI
. PARTIl
PARTIII
PARTI
PARTII
PARTIII
PARTI
PARTII
PARTIII
PARTI
PARTII
PARTIII
PARTI
PARTII
PARTIII
PARTIV
PARTV
PARTVI
PARTVII
PARTVIII
ntIRDSOtEDULE
Working Standard Weights
Working Standard Metre Bar
Working Standard Capadty Measures
FOUR1HSCHEDULE
Reference Standard Balances
Secondary Standard Balances
Working Standard Balances
FIFTHSOtEDULE
Weights (Other than Carat weights)
carat Weights
Standard Weights for testing of High
Capacity Weighing Machine
SDCTHSCHEDULE
Uquid capacity Measures
Dispensing Measures
Liquor Measures
Length Measl,lres(Non-Aexible)
. Folding Scales
Fabric or Plastic Tape Measures
Steel Tape Measures
. Surveying Chains
PARTIX Tapes for Use in Measurement of 011
Quantities
SEVENTH SCHEDULE-HEADINGA
SPEOF,[CAllONS FOR NON-AUTOMAllC
WEIGHINGINSJRUMENlS
SEVENTH SCHEDULE-HEADINGB
PARTI
PARTII
Beam Scales
Counter Machines
SEVEHTH SOtEDULE- HEADINGC
AlITOMAllC RAIL WElGHBRIDGE
SEVENTH SOtEDULE- HEADINGD
AUTOMAllCGRAVIMETRIC .FIWNG
INSTRUMENTS
SEVENIli SOtEDULE- HEADINGE
DISCONTINUOUSTOTAUZlNGAUTOMAllC
WEIGHINGINSlRUMENT(TOTAl.lZING HOPPER
WBGHERS)
EIGHtHSOiEDUlE
SPEaFICA1l0NSFOR MEASURINGINSTRUMENTS
PARTI
PARTII
PARTIII
Volumetric Container Filling Machines
Bulk Meters
Water Meters
- .... -- - -----:
[~II-~ 3(i)] 325
PARTIV Measuring Systems for LiquidsOther
than Water
Volumetric Container Type liquid
Measuring Device
alnlcal Thermometer
Monometers of Instruments for
MeasurIng Arterial Blood Pressure
(Sphygmomanometers)
Taximeter
Compressed gaseous fuel (CNG)
measuring systems for vehldes
NINTH SCHEDULE
PROCEDURE FOR CARRYING 0t1T
CAUBRATJON OF VEHICLE TANKS fTC.
PARTV
PARTVI
PARTVII
PARTVIII
PARTIX
PARTI CalibratIon of Vehicle Tanks for
Petroleum Productsand other Liquids
Method for calibration of Vertical 011
Storage Tanks
Method for Computation of capadty
Tables for Vertical Oil Storage Tanks.
TEN'nfSOiEDULE
APPllCAlION F()~ FORREGlSTRAlIONOF
IMPORTER OF WEIGHTS AND MEASURES
B..fVENTHSOIEDULE
RE~RT08E~NTAlNED8YTHE
MANUFACTURERS/DEALERS/REPAIRERS OF
WEIGHTS AND MEASURES
TWaFTHSCHEDULE
PARTII
PARTIII
SCA.LE OF FEE
lHIRJW(THSCHEDUl.E
Format for n~mlnation of the Director
by the Company
fIRSl'SCHEDULE
DENOMINAnO~,MATERJALS,SHAPEAND
P~BLEERRORS,IN RESPECTOF
REFERENCE STANDARDS
[SBe Rule3}
PART I REFERENCE STANDARD WEIGHTS
1. Denominations
Kilogramseries Gramseries Milligram series
(1) (2) (3)
5 500 500
2 200 200
2 200 200
1 100 100
50 SO
20 20
'-17u t;nil - i')..
(1) (2)
~---=--- =-=---=-=-=--=-- ~- -___:_:_:.. _::_-=-:-:....=..=---...::...::.:_-'- ---=-=----..:..=.=-----:____::_::.- --=-----:;;....- -.=------- ---
(3)
20·
10
5
2
2
1
20
10
5
2
2
1
2. Materials
(a) WeIghts of 5 kg to 19 shalf be made from
admiralty bronze (88Cu, 10So, 2Zn), nickel
chromium alloy (80 Ni, 20 Cr) or austenItic
stainlesssteel (25Ni,20Cr) or (20Ni,250).
(b) Weights of 500 mg to 10mg shalf be made
from wire of either pure platinum, nickel
chromium alloy (80 Ni, 20 Cr) or austenitic
staInless steel (25 NI, 20 Cr) or (20 Ni, 25
Cr).
(c) WeIghts of 5 mg to 1 mg shall be made of
aluminium wire. Copper, silicon and zinc
contained as impurities in aluminium shall
not exceed 0.3 per cent in the aggregate.
Note:Thematerial used for all the weights shall
be non-magnetic and it shall be ensured that the
finished weIghts are also practically non-magnetic.
3. Shapeand finish
(a) For kilogram and gram series-
Integra! cylindrical body with knob rounded
at top.
(b) For milfigram series-
The weights shall be made from the wire
having five segments for sao, 50, 5 mg
weights, two segments for 200, 20, 2 mg
weIghts and one segment for 100, 10, and
1mg weights. One end of the wire shaff be
bent at right angles for the purposesof lifting
It with a pair of forceps.
(c) The denominations shall be marked only on
kilogram and gram series weights.
(d) The entire surface of the weights, including
their base and corners shall be free from
any roughnessand the surfaceof the weights
when inspected vlsuafly shall not show any
porosity and shall have a mirror finish.
4. Maximum permissible errors
Denomll18tion Permissible error:t mg
(1) (2)
Skg
2kg
1 kg
7.5
3.0
1.5
~THE'GAZETIE!OF 'INDIA: EXTRAORDINARY [PARTII-SEC. 3(i)]326
(1)
500g
200g.
100g
SOg
20g
109
Sg
2g
19
SOOmg
200mg
100mg
50mg
20mg
10mg
5mg
2mg
.(~)
rO.75 ..
:0.30
:0;15
~O;lO
:0;080
,0:060
;0;050
0;040
:0;030
0.025
0.020
0.015
0.012
0.010
0.008
0.006
0.006
1mg 0',006
5. Protective and canying case
(a) These weights shall be stored In their boxes'
made from teakwood or any other suitable
non-corrosive material with proper housing
lined with chemically neutral velvet, chamois
leather or soft plastic material. Wood used
in such boxes shall be reasonably free from
resins and volatile materials. Glue shall not
be used for fixing velvet or such other
material. The weights shall be housed in
such a manner soasto avoid their movement
during transit.
(b) Each milligram weight shall be provided with
a separate housing. A covering glass or a
sheet of any other transparent and non
reactive and non-corrosive material shall be
provided so as to ensure that these weights
are not dislocated during transIt.
(c) A suitable device for lifting the klloqramand
gram weights covered with chamois leather
or other suitable material shall be provided.
A pair of forceps capable of liftIng easily
milligram weights shall also be provided,
6. Insalption
The boxes contaInIng the weights shall have the
following Insaiptlons:
(a) The words 'Reference Standards Weights' .
(b) The Identification number of such boxes,
(c) The name of the manufacturer,
(d) The material used for weights,
(I) kilogram and gram series,
(ii) milligram series,
(e) The year orrnanutecture,
(f) The verification mark of the NPL.
PART 11- REFERENCE STANDARD METRE BAR
1. Material
The Reference Standard Metre Bar (hereafter
called metre bar) shall be manufactured from 58 per
cent nIckel-steel.
2. Shape ind dimensions
(8) The metre bar shall be of H-sectlon,
approximately 25 mm x 2S mm (as per
Figure 1)
(b) The overall length of the metre bar shall be
1030 ±1 mm and the graduated length shall
be 1008 mm.
(c) Ungraduated space of 11 mm shall be left
after the last graduation mark.
3. Finish
The graduated surface shall be bright highly
polished, and free from surface Irregularities in the
neighbourhood ofthe graduation marks.
4. GI'Bdu6t1ons
(a) The main scale shall be situated on the
neutral plane and shall be graduated In
mlllimetres throughout from 0 to 1000 rnm.
(b) The main scale shall also have one additIOnal
mm mark before 0 and another after 1000
mmmark.
(c) An additional fine scale shall also be provided
at each end of the main scale for calibrating
a mlcrometre microscope. This fine scale
shall consist of ten 0.1 mm graduations
(1 mm sub-divided Into 10 parts) and shall
be situated before the first graduation mark
after leaving a blank space of 2 mm and also
after the last mark with the same blank
spacing.
(d) The graduation marks shall be well-defined,
of symmetrical section and havedean edges.
(e) The width of graduation marks shall be
between 8 and 10micrometres. This width
shall be constant to within ten per cent over
the length of each mark between the
longitudinal setting lines.
(f) The graduation marks shall not differ in width
one from another by more than ± 10% of
the average width of all the marks.
[tfl7T II-~ 3(i)]
(g) The graduation marks shall be parallel to
one another to within one mlcrometre
between the longitudinal setting lines.
(h) The graduation marks shall besquare to the
scale axis to within ten minutes of arc.
(i) The length of graduation marks shall be as
follows :-
2 mm for half em marks.
1mm for mm marks.
The marksshall bedisposed equally oneither
side of an Imaginary centre line. .
(j) The lengths of the graduation marks on the
two fine scales referred to In 4(c) shall be
as follows:-
3mm for first and last mark.
2 mm for 0.5 mm marks.
1mm for 0.1 mm marks.
(k) The Bessel points shall be indicated by two
vertical lines marked on either external side
of the metre bar. The Bessel points shall be
571mm apart, and shall be disposed equally
on either side of the 50 mm mark.
(I) No figures or numerals shall be marked on
the surface of the main scale.
(m) Whensupported at the markedBessel points,
the graduated surface shall be flat to within
0.05 rnm, l.e. all points on the surface shall
be between two parallel planes 0.05 mm
apart. .
5. Auxiliary scale
(a) An auxiliary scale shall be marked on one of
the top edges of the metre bar.
(b) The auxiliary scale shall consist of 1000
marks corresponding to the marks of the
main scale. .
Cc). The marks of the auxiliary scale shall be
. collinear (i.e., passing through the same
vertical planes) with the graduation marks
of the main scale to within ±0.1 mm.
(d) The width of graduation marks shall be not
more than 100 micrometres and shall be
clearly visible to the naked eyes having
normal vision.
(e) The length of the graduation marks shall be :
2.5 mm for em marks.
2.0 mm for half cm marks.
1.5mm for mm marks.
One of the ends of all the marks shall lie on
a straight line.
(f) The centimetre graduation marks shalt be
numbered in the Increasing order of
numeration.
(g) The height of the numerals and the letters
shalt be apprOXimately 3mm.
6. Setting lines
(a) A pair of longitudinal setting lines shall
transverse the graduation marks and shall
be parallel to the scale axis to within one
minute of arc.
(b) The two longitudinal lines shall be disposed
symmetrically on either side of the centre of
the graduation marks.
. '"
~~::'i>.: 1!
REFERENCESTANDARD METRE BAR
Rgure-l
327
328 ·THE :.GAZETTE OF INDIA: EXTRAORDINARY
(1)
[PART ll-Soc. 3(i)J
1(2) (3)
100 100
ISO SO
20 20
20 20
10 10
5 5
2 2
2 2
1 1
(c) The separation of the longitudinal setting
lines shallbe.0.2 mm andrthelrwidth shall
be in between B,and·10:micrometres.
(d) EachIol)9ftudlnaJsetti'19:tineshall be straight
to wlthln~30mlcrometres.
(e) The longitudinal setting linesshall be parallel
to eaeh.otherto.within SO.micrometres.
7. Maximum permissible error
(a) When the metre bar ts supported on its
marked: Bessel.polnts, the errors In length
between.anytwoqraduation marks of the
main scale:attnetemperature of 2O"C,shall
not exc.eed!O;1:)10·mm.
(b) In the ;ta5e of the flne scales, the error
between any two 0.1 mm marks shall not
exceed 0.005 mm.
8. Insaiption
The metre bar shall bear the following Inscription:
(a) the words "REFERENCESTANDARDMETRE
. BAR",
(b) the identification number of the metre bar,
(c) the verification mark of the NPL, after the
first calibration and marks of subsequent
. verification to bemade on the plate of the
carrying case of the metre bar,
(d) the name of the manufacturers,
(e) the material of the metre bar,
(f) the words, figures and letter "STANDARD
AT 20°C',
(g) the year of manufacture.
9. Protective and carrying case
(a) The standard metre bar shall be housed in
a case made from suitable material and
provided with a handle, lined Internally with
velvet, a plastic material or any other
material and In such a way that the metre
bar is not likely to be damaged, particularly
by shocks or corrosion.
(b) The case shall have affixed on It a plate
bearing the inscription "REFERENCE
STANDARD METRE BAR" and the
identlflcatlon number.
SECONDSOiEOUlJ:
DENOMlNAnONS, MATERIAlS, SHAPE AND
PERMISSIBlE ERRORS
IN RESPECT OF SECONDARY STANDARDS
[SeeRule 4
PARTI-SECONDARY STANDARD WEIGHTS
J. Denominations
Kilogram series Gram series Milligram series
(1) (2) (3)
10 500
5 200
2 200
500
200
200
2
1
2. Materials
(a) Weights of 10 kg to 1 g shall be made from
admiralty bronze (B8 Cu, 10 Sn, 2 Zn), or
nickel-chromium alloy (BO Ni, 20 Cr) or
austenitic stainless steel (20 Ni, 25 Cr) or
(25 Ni, 20 Cr).
(b) Weights of 500 mg to SOmg shall be made
from cupro-nickel (75 Cu, 25 Ni), or nickel
chromium alloy (80 Ni, 20 Cr), or austenitic
stainless steel (20 NI; 25 Cr), or (25 NI, 20
Cr).
(e) Weights of 20 mg to 1mg shall be made of
aluminium sheets. Copper, silicon and zinc
contained as impurities In aluminium shall
not exceed 0.3 per cent In the aggregate.
3. Shapeand finish
(a) For kilogram and gram series-Integral
cylindrical body with knob flattened at the
top. Weights of 10 kilogram to 100 gram
(both inclusive) shall haveadjusting devices.
(b) For milligram series-the weights shall be
In the form of square sheets, one of the
corners being bent at right angle.
(c) The denominations shall be marked only on
kilogram and gram series weights. .
(d) The entire surface of the weights, including
their base and corners shall be free from
any roughness and the surface of the
weights, when inspected visually, shall not
show any porosity and shall have a mirror
polish appearance.
4. Maximum permissible error
Denomination Permissible error.:t mg
10 kg
5 kg
2 kg
1 kg
500g
2009
100g
50g
so
25
10
5
2.5
1.0
0.5
0.30
(1) (3)
329
(2)
20g
lag
59
29
19
SOOmg
200mg
l00mg
SOmg
20mg
10mg
Smg.
2mg
Img
0.25
0.20
0.15
0.12
0.10
0.08
0.06
0.05
0.04
0.03
0.02
0.02
0.02
0.02
5. Protective and canying case
(a) These weights shall be stored In their boxes
made from teakwood or any other suitable
non-corroslve material with proper housing
lined with chemically neutral velvetr chamois
leather or soft plastic material, Wood used
in such boxes shall be reasonably free from
resins and volatile materials, Glueshall not
be used for fixing velvet or such other
material. The weights shall be housed in
sucha mannersoas to avoidtheir movement
during transit.
(b) Eachmilligram weight shall be providedwith
a separate housing. A covering glass or a
sheet of any other transparent, non-reactive
. and non-corroslvematerial shall beprovided
so as to ensure that these weights are not
dislocated during transit.
(c) A suitable device for lifting the kilogram and
gram weightsr covered with chamois leather
or other suitable material, shall be provided.
A pair of forceps capable of lifting easily
milligram weights shall also be provided.
6. Inscription
The boxes containing the weights shall have the
following inscriptions:-
(a) the words 'SECONDARY STANDARD
W8GHTS',
(b) the Identification number of the secondary
standard weIghts,
(c) the name of the manufacturer,
(d) the material used for weights
(i) kilogram & gram series
(ii) milligram series,
(e) the year of manufacture,
(fj the mark of verification.
PARTD~SECONDARYSTANDARDMETREBAR
1. Materia'
The secondary standard metre bar (hereafter
called metre bar) shaHbe manuf!ctur~ from 58 per
cent nickel-steel.
2. Shape and dimensioni
(a) The metre bar shallhavea rectangularcross
section with dimensIons 30mm x lSmm
approximately.
(b) The top surface shall have two rectangular
grooves along its length (as per Figure 2).
(c)· The pverall length of the measure shall be
. 1030±1 rnrn and the graduated length shall
bel010mm.
(d) Ungraduated space of 10 mm shall be left
after the last graduatIon mark.
3. Finish
The graduated surface shall be bright, highly
polished and free from surface Irregularities in the
neighbourhood of the graduatIon mark.
4. Graduations
(a) The metre bar shall be graduated in
milllmetres throughout from 0 to 1000mm.
(b) A lengthof 10mm beforethe zerograduation
mark shall also be graduated in millimetres.
(c) The scale shall be regular. The width of the
graduation marksshallbe between thirty and
fifty mierometres,
(d) The width of the graduation marks shall be
uniform to within ± ten per cent of the
average width of all the marks.
(e) Eachgraduation marks shall be straight to
within ten micrometres over its length.
(f) The graduation marks shall be parallel to
one another to within ten mierometres.
(g) The graduation marks shall be square to the
scale axis to withIn twenty minutes of arc.
(h) The graduation marks representing
centimetres shall be longer than those
representing half centimetres and the
graduation marks representing half
centimetres shall be longer than those
representing millimetres.
(I) The length of the graduation marks shall be
not less than:
2 mm for mm marks.
3 mm for half cm marks.
4 mm for em marks.
These marks shall be disposed equally on
either side of an Imaginary centre line
defined by the two setting lines.
330 -'THE 'GAZETTE OF INDIA: EXTRAORDINARY [PARTU-SEC. 3(i»)
(j) There sheillbe two short Iongftudinal;setting
Jineseach'of·S mm in length which shall be
drawn leavl~g a'blank space.of 2 mm, the
one before theflrstand.the-other after the
last graduation mark. Jhe:longitudinal lines
shall be:on a straight line which represent
the imC!lglna.ycentral'llneand the departure
from the eentralune.snallbe not more than
O.lmm.
(k) When sl!Pported'on the Bessel points or on
a f18i surface ,the graduated surface shall
be flaHo\wtthln,O:OSmm, i.e. all the points
on the,surface shall be between two paraUel
planes:O;OSmm apart.
S. Auxiliary scale
(a) Auxiliary scale shall be marked on one of
the top edges of the metre bar.
(b) The auxiliary scale shall consist of centimetre
and half centimetre marks corresponding to
the marks of the main scale.
,(c) The marks of the auxiliary scale shall be
collinear (passing through the same vertical
planes) with the graduations of main scale
towithln±O.l mm.
(d) The width of the graduation marks shall be
not more than one hundred mlcrometres.
(e) The graduation marks representing
centimetres shall be longer than those
representing half centimetres.
(f) The length of the graduation marks shall be
not less than:
3mm for em marks, and
2 mm for half em marks.
One of the ends of the marks shall lie on a
straight line.
(g) The centimetre graduation marks shall be
numbered in the Increasing order of
numeration.
(h) The height of the numerals and the letters
shall be approximately 3mm.
6. M6ximum permissible em»:
The error on the length between any two
graduation marks on the secondary standard metre
bar, at the standard temperature of 20°C, shall not
exceed the value "e" calculated according to the
folloWing formula:
e = ± (25 + L/40) micrometres
Where L Is the nominallengttl in millimetresof that
part of themetre bar betweenthe two graduationmarks,
the error on which is being determined. The calculated
value or"e" shall be rounded to the nearest integer.
7. Insaiptlon
The metre bar shall bear the ,following
inscriptions:
(a), the words "SECONDARYSTANDARDMETRE
BAR",
(b) an Identification number of the secondary
standard metre bar,
(c) the name of the manufacturer,
• , I I I. it .. • .. if ... .. . " .. '.! '" .~' .. ..... III II ~
, '
I
~ '" ,. I
• j..--' -I,..
1 'Awrmnn
SECONDr\RY STANMRD METRE BAR
FlQURE·Z
•
['WT n-~ 3(i)] 331
(d) the material of the metre bar,
(e) the words, figures and letter "STANDARDAT
20°CH,
(f) the year of manufacture,
(9) the mark of verification on the plate of the
carrying case of the metre bar.
B. Protective 6nd carrying case
(a) The metre bar shall be housed In a case
made from suitable material and provided
with a handle, lined internally with velvet, a
plastic material or any other material, and
in such a way that the measure Is not likely
to be damaged~ particularly by shocks or
corrosion.
(b) The case shall have affixed on It a plate
bearing the inscription "SECONDARY
STANDARD METRE BAR" and the
identiflcatlon number.
Note: The existing secondary standard metre
bars may differ In minor detaiis in regard to setting
lines and inscriptions, etc.
PARTID"-SECO".DARY STANDARD CAPACITY
MEASURES
J. Denominations
Litre series (1) Millilitre series (ml)
5
2
1
sao
200
100
50
20 .
Note: 1 litre = 1 dml - 0.001 mli 1ml= 1em'
2.Materlal
Secondary standard capadtv measures shall be
cast out of admiralty bronze of the same composition
as is employed In the case of secondary standard
weight.
3. Shape
(a) The secondary standard capacity measure
of five litre shall be cylindrical and have its
inside diameter equal to the height cif the
measure. This shall have two handles
attached securely to its sides.
(b) The measure of 2 I and below shall be of
the same shape as above but shall not have
any handles.
(c) The denominations of the secondary
. standard capacity measures shall be
engraved on the outside surface. .
(d)' Each secondary standard capacity measure
shall be provided with a specially selected
striking glass on the measures and glasses
shaII be securely packed in velvet lined
teakwood boxes.
4. Maximum permissible errt1r
Denomination . PermissIble error +ml
51
21
11
SOOml
200ml
100 ml
SOml
20ml
2
1
0.8
0.5
0.4
0.3
0.2
·0.1
. 5. Protective and canylng CIISes
These capacity measures stlall be stored in their
boxesmade from teakwood or any other suitable non
corrosivematerial with proper housing linedwith velvet,
charnels leather or soft plastk material. Wood used
In such boxes shalf be reasonably free from resins
and volatile materials. Glue may not be used for fixing
velvet or such other materials. Eachcapacity measure
shall be housed in such a manner so as to avoid their
excessive movement during transit.
Eachstriking glass of the capacity measure shall
besecurely housed in proper grooves so as to protect
them from breakage during transit.
6. Inscriptions
The boxes containing these capacity measures
shall have the following inscrlptlons:-
(a) the Inscription SECONDARY STANDARD
CAPACITY MEASURES;
(b) the Identification number of secondary
standard capacity measures;
(c) the name of the manufacturer;
(d) the year of manufacture;
(e) the mark of verification of proper verification
authority.
THIRDSOIEDULE
DENOMINAnONS, MATERIAL,SHAPE AND
PERMlSSIBLEERRORSIN RESPECr OFWORICING
STANDARDS
[See Rule 5]
PARTI- WORKINGSTANDARDWEIGHlS
J. Denominations
Kilogram series Gramser/es Milfigram series
(1) (2) (3)
20 500 SOO
10 200 200
10 200 200
5 100 100
2 50 50
2 20 20
1 10 10
332
(2) (3)
THE GAZETTE OF INDIA: EXTRAORDINARY (PARTI1-SEC. 3(i)]
'(2)
5
2
2
1
2. Material
(a) Weights,of 20' kg to 1 g shall be cast from
admiralty bronze:(88 Cu, 10 Sn, 2 Zn) or
madejrom cupro-rilckel (75 Cu, 25 Ni) or
nickel .chrormum alloy (80 NI, 20 Cr) or
austenltlc:stalnless .steel (25 NI, 20 Cr) or
(20 NI,:25 Cr). .
(b) Weights Of:SOO:mgto100mg shall bemade
from admiralty ·bronze (rolled) (88 Cu, 10
Zn, :2 Sn) sheets or from the sheets of nickel
chromium :alloy (80 Ni 20 Cr) or austenitic
stainless steel (25 Ni, 20 Cr) or (20 Ni, 25
Cr).
(c) Weigt'ds 0(50 mg to 1 mg shall be made of
alumlnfum sheets. Copper, silicon and iron
contained as impurities in the aluminium
shall not exceed 0.3 per cent in the
aggregate.
3. Shapeand finish
(a) Weights of 2.0 kg and 10 kg shall be
cylindrical In shape and shall be cast in two
parts, the top part being screwed snugly Into
the bottom part. The top part shall be cast
in the form of a handle for lifting purposes.
The two parts after assembly shall be locked
by means of a set screw over which the seal
of the verifying authority shall be affixed.
(b) Weights of 5 kg to 200 gm (inclusive) shall
be cast In two parts, the top part being
screwed snugly into the bottom part. The
top part shall be cast in the form of a knob
for lifting purposes. The two parts, after
assembly, shall be locked by means of a set
screw, over which the seal of the verifying
authority shall be affixed.
(c) Weights of 100 9 to 10 9 (inclusive) shall be
as in (b) above except that there shall be no
locking arrangement.
(d) Weights of 5 g to 1 g (inclusive) shall be
integral weights with knob.
(e) Weights of 500 mg to 1 mg (inclusive) shaH
be of square shape with the one of the sides
bent at right angles to the flat surface for
ease of handling.
(f) The denominations shall bemarked on the
weights.
5
2
2
1
(g) The entire surface of the weights, including
their base and corners shall be free from
roughness.
The surface of the weights, when inspected
visually, shall not show any porosity and shall have a
mirror polish appearance.
4. MaxImum permissible error
The permissible errors in excessand in deficiency
shall be as follows:-
DenomInation PennisSibleerror:t mg
20 kg 300
10 kg 150
. 5 kg 75
2kg 30
1kg 15
500g 7.5
2009 3.0
100g 1.5 .
50g 1.0
20g 0.8
109 0.6
59 0.6
2g 0.4
19 0.3
500mg 0.25
200mg 0.20
loomg 0.1S
SOmg 0.12
20mg 0.10
10mg 0.08
Smg 0.06
2mg 0.06
1mg 0.06
5. PrtJ.tectJveand carrying case
(a) These weights shall be stored in their boxes
made from teakwood or any other suitable
non-corrosive material with proper housing
linedwith chemically neutral velvet, chamois
leather or soft plastic material. Wood used
in such boxes shall be reasonably free from
resins and volatile materials. Glue shall not
be used for fixing velvet or such other
material. The weights shall be housed in
sucha manner soas to avoid their movement
during transit.
(b) Eachmilligram weight shall be provided with
a separate housing. A covering glass or a
sheet of any other transparent, non-reactive
[trPT II-~ 3(i)] 333
and non-corrosivematerial shall be provided
so as to ensure that these weights are not
dislocated during transit.
(c) A suitable device for lifti'19 the kilogram and
gram weights, coveredwith chamois leather
or other sUltaqiematerial, shall be provided.
A pair of forceps capable of lifting easily
milligram weights shall also be provided.
6. Inscription
The boxes containing the weights shall have the
following inscriptions :-
(a) the words 'WORKING STANDARD WEIGHTS~
(b) the identification number of the working
standard weights,
(c) the name of the manufacturer,
(d) the year of manufacture,
(e) the marks of verification.
PARTU-WO~NG STANDARDMETREBAR
1. Material
, The working standard metre bar (hereinafter I
called metre bar) shall be manufactured from 58 per I
cent nickel-steel, or austenitic stainless steel, or I
stainless steel with 13 per cent chromium or pure I
nickel (minimum purity 99 per cent). I
2. Shape and dimensions '\
(a) The metre bar shall have a rectangular cross
section of minimum dimensions 20 mm x 10
mm. The existing cross-section with
dimensions 30 mm x 15 mm shall be
preferred.
(b) The overall length of the metre bar shall be
1030± 1mm and the graduated length shall
be 1010 mm.
(c) Ungraduated length of 10 mm shall be left
after the last graduated marks.
3. Finish
The graduated surface shall be bright, nicely
polished and free from surface irregularities In the
neighbourhood of the graduation marks.
4. Graduations
(a) The metre bar shall be graduated in
millimetre throughout from 0 to 1000 mm
on the wider upper surface.
(b) 'A length of 10mm before the zerograduation
mark shall also be graduated In mlilimetres.
(c) The scale shall be regular. The thickness of
the graduation marks shall be uniform and
, shall lie between 30 and 80 mkrornetres,
(d) The width of the graduation marks shall be
uniform to within ± fifteen per cent of the
average width of all the marks.
(e) The graduation marks representing
centimetres shall be longer than those
representing half centimetres and the
graduation marks representing half
centimetres shall be longer than those
representing miJlimetres.
(f) Each graduation mark shall be straight to
within ten mkrometres over its length.
(g) The graduation marks shall be parallel to
one atQther to within ten mlcrometres.
(h) The length of the graduation marks shall be
not less than--
3mm for mm marks.
5 mm for half em marks.
8mm for an marks.
(I) The centimetres graduation marks shall be
numbered in the Increasing order of
numeration.
(j) The height of the numerals and the letters
(symbols) shall be approximately 3mm.
(k) The graduation marks shall be square to the
scale axis to within 30 minutes of arc.
S. Cursor
(a) The errors on ij,'e length measure under
'verification shall be determined by means
of a scale marked on a plate, made from
transparent material, whlchis carried by II
cursor capable of moving along the length
of the metre bar. The plate shall have
appropriate and constant dimensions and
thickness.
(b) The scale on the plate shall :
(I) either be a length of 9 mm divided
into 10 parts thus forming a Vernier
scaleto read the errors to the nearest
of 0.1 mm; or
(II) one millimetre divided into 10 parts
for reading the errors directly to the
nearest of 0.1 mm.
(c) Tbe thickness of the graduation marks on
the scale shall be less than that of the
graduation marks on the metre bar.
(d) The graduation marks on the scale shall be
Inscribed on the surface facing the
graduation marks on the metre bar.
(e) The readings shall be taken by means of a
magnifying glass, the magnification of which
shall be not less than 5X if the scale Is
graduated in 0.1 mm and not lessthan 3X If
the scale is of Vernie~ type.
334 THE GAZETTE OF INDIA: EXTRAORDINARY [PART II-Soc. 3(i)]
(f) The cursor shall 'be such that ft would be
possible to move it smoothly without jerks,
along a straight line from one end of the
measure.to the other.
(g) A mechanism to raise, ·Iower and laterally
move the measure under verification, within
a view to putting its graduated surface at a
proper level and aligning its zero mark with
that of thernetre bar shall be provided.
(h) For faCilitating the verification of end
measures, two vertical stops bearing
retereneeunes shall be provided. The first
stop shallbe such that its reference line can
be aligned with the zero mark of themetre
bar. The second stop shall be capable of
moving along the entire length of the metre
bar.
6. Maximum pennlsslble errors
(a) The error on the length between any two
graduation marks on the working standard
lengthmeasure, at the standard temperature
of 20°C, shall not exceed the value "e"
calculated according to the following
fonnula:
e = (50+L/20) micrometres
where L is the nominal length Inmllllmetres
of that part of the metre bar between the
two graduation marks, the error on which is
being determined. The calculated value of
"e"shall be rounded to the nearest Integer.
(b) The errors on the length between any two
graduation lines on the plate shall not exceed
± 20 micrometres.
7. Insaiption
The metre bar shall bear the following Insaiption:
(a) the words "WORKING STANDARDMETRE
BAR~
(b) identification number of the metre bar,
(c) the name of the manufacturer,
(d) the material of the metre bar,
(e) the words, figures and letter "STANDARDAT
20°C",
(f) the year of manufacture.
8. Protective and carrying case
(a) The standard metre bar shall be housed in
a case made from suitable material and
provided with a handle, lined Internally with
velvet, a plastlc material or any other
material and In such a way that the metre
bar is not likely to be damaged, particularly
by shocks or corrosion.
(b) The case shall have affixed on It a plate
bearing the Inscription "WORKING
STANDARD METRE BAR" and the
Identification number.
Note : The existing working standard length
measure (metre bars) may differ in minor details in
regard to Inscriptions, etc. on it.
PARTW-WORKING STANDARD CAPACITY
MEASURES
1.·Denomination
LItre series (I) Millilitre series (ml)
10
5
2
1
500
200
100
50
20
2. Material
Working standard capacity measures shall be
pressed out of oxygen free, deoxidized annealed
copper sheets of deep drawing quality.
3. Shape
(a) Working standard capacity measure of
10 IItres shall becylind_ricaland have Its Inside
diameter approximately equal to the height
of the measure. this shall have two handles
attached securely to its sides.
(b) Working standard capacity measures of
511tresand below shall be of the same shape
as above but shall not have any handles.
(c) The outside of the body of the working
standard capacity measuresshallbe oxidIZed
to give a smooth dull black surface and the
InsIde shall be tinned.
(d) The denominations of the working standard
measures shall be engraved on the outside
surface.
(e) Each working standard capacity measure
shall be provided with spedally selected
striking glass and the measures and glasses
shall be securely packed in velvet lined
teakwood boxes.
4. Maximum permissible error
Denomination PermiSSibleerror in ml.:t.ml
10lltres 8
511tres 4
. 211tres 2
1 litre 1.5
. 500 ml 1.0
200ml 0.8
100 ml 0.6
SO ml 0.4
20ml 0.2.
['WT II-~ 3(i)]
5. Pipette measures
Pipettesof the following description may also be
used as working standard measures:
(a) One mark pipettes of capacities 10ml and 5
mi.
(b) Graduated pipettes of capacities 5 ml
gradua~edat every tenth of mi.
6. Delivery time and maximum permissible
errors of pipette measures
Den0n:tination Delivery time
ml In seconds
Minimum Maximum
Permissible
error ( + ml)
10
5
5
(Graduated)
25
20
40
0.04
0.03
0.05
15
10
10
7. Protective and carrying cases
These capacity measures shall be stored in their
boxesmade from teakwood or any other suitable non
corrosivematerial with proper housing lined with velvet,
chamois leather or soft plastic material. Wood used
in such boxes shall be reasonably free from resins
and volatile materials. Glue may not be used for fixing
velvet or such other materials. Eachcapacity measure
shall be housed in such a manner soas to avoid their
excessivemovement during transit.
Eachstriking glass of the capadty measure shall
be securely housed In proper grooves so asto protect
them from breakage during transit.
8. InSCriptions
The boxes containing these capacity measures
shall have the following inscriptions: .
.(a) the words "WORKING STANDARD CAPACfTY
MEASIJ~ES/~
(b) the ldentlfkation number of the capacity
measures,
(c) the name of the manufacturer,
(d) the year of manufacture,
(e) the mark(s) of verification of proper
verification authority:
FOURllI SCHEDULE
SPECFICATIONS FOR STANDARD EQUIPMENT
[See Rules 7, 8 and 9]
PARTI-REFERENCE STANDARD BALANCES
1. Every reference standard balance shall be of
such robust construction and have such metrological
qualities so as to ensure the continued good
performance, as indicated In paragraph 2.
2. Sensitivity figure/readability and precision of
measurement of every reference standard balance
shall be such as to give overall precision of
measurement of 1part in one nillllon for weights from
10 kg to 10 9 and ± 0.01 mg for weights from 5g to
1mg.
PARTII-5ECONDARVSTANDARDBAlANCES
1. Every secondary standard balance shall
conform as regards capacity, sensitivity figure in mg
per division, minimum scale division, variation In
sensitivity figure with respect to load and overall
accuracy of measurement, to the spedfications as
indicated below:
capaCItY senSitiVItYfigure Min. scalediVISion Maximum vanaton Minimum overall
mg/dlv. Insensitivity figure accuracy of
with respect to load measurement
1 2 3 4 5
20 kg 25 l.Smm 10 percent 25 mg In 10 kg
Skg 7.5 1.0mm 10 percent 7.5 mg In 2 kg
1kg 1.S 1.0mm 10 percent 1.5 mg in 500 g
200g 0.5 1.0mm 10 percent 0.5 mg in 50g
20g 0.1 1.0mm 10 percent 0.01 mg in 1mg
2g 0.02 0.75 mm 10 percent 0.02 mg in 1 mg
2.. the standard deviation of the 10 consecutive rest points for every secondary standard balanceshall not
be more than one scale division.
335
[PART II-Soc. 3(i)]336 THE .GAZETTE OF INDIA: EXTRAORDINARY
interval as given below:-3. Theideviation'ln arm ratio from uriity, for
every secondary standard equl-arm balance shellnot
be more than-a fractlon.equal .to sensitivity figure
divided by full load.(both beil19taken'in the same unit).
4. The variation in time iperiods at different
loads for every secondar;ystandard balance shall not
be more than 20 per.cent.
5. Every~secondary·standard 'balance shall be
provided with' a:device so that the contact between
the knife-edges antj(thelr.respective planes is broken
when the balence'lsdn ar.rested position.
6 .. The -secondery standard balance shall,
ordinarily, be used.for indoor war!<in laboratories.
7. Every secondary standard balance of digital
type shall conform 'as regards value of verification scale
capacity Maximum value Type of weights
of verification to be verified
scale interval
20 kg 1mg 20 kg to 500 g
200 g 0,01 mg 200 g to 1 mg
PARTm- WORKINGSTANDARD BALANCES
1. Working standard balances may be of the
following two types:-
(a) Equi-arm types balances;
(b) Digital type balances.
2. Every working standard balance of equi-arm
type shall conform, as regards capacity, sensitivity
figure, maximum variation In sensitivity figure with
respect to load and maximum overall inaccuracy of
measurement to the Specification as Indicated below-
Capacity Max. Sensitivity Maximum variation Minimum overall 6CCUracy of
figure/division in sensitivity figure measurement
50 kg 100 mg 20 per cent 100 mg in 10 kg
5 kg 10 mg 20 per cent . 10 mg in 500 9
200g 1 mg 20 per cent 1 mg in 100 g
50 9 0.4 mg 20 per cent 0.4 mg in 5 9
2g 0.05 mg 20 per cent 0.05 mg in 1 mg
2.1 The standard deviation of ten consecutive
rest points for e-Iery working standard balance shall
not be more than one scale division.
2.2 The deviation In arm ratio from unity, for
every working standard equi-arm balance shall not be
more than the fraction equal to sensitivity figure divided
by the full load (both being taken in the same unit).
3. Every working standard digital type balance
shall conform, as regards value of verification scale
Interval as given below:-
capacity Max. value of Type of weights
verification scale to be verified
interval
50 kg
20 kg
19
0.1 g
Non-bullion : 50 kg
and 20 kg
Bullion : 10 kg,
5 kg;
Non-bullion : 20 kg
t02kg
Bullion: 2 kg to
500g;
Non-bullion: 2 kg to
2009
Bullion ; 200 g and
below;
Non-bullion : 200 g
and below
2kg 10mg
200g O.lmg
4. The standard deviation of the 10consecutive
rest points for every working standard balance shall
not be more than one scale division.
5. The deviation in arm ratio from unity, for e-Iery
wor!<lngstendard equi-arm balance shall not be more
than a fraction equal to sensitivity figure divided by full
load (both being taken in the same unit).
6. The variation in time periods at different load
for every working standard balance shall not be more
than 20 per cent.
7. Every indoor type working standard balance
shall be provided with a device so that the contact
between the knife-edges and their respective planes
is broken when the balance is in arrested position.
Note: For verification of bullion or carat weights,
only Indoor type working standard balances shall be
used.
FIfTH SCHEDULE
[See Rule 11)
PART-I
Weights (Other than Carat Weights)
General
This Part deals with the following categories of
weights:-
aCrw.~ :1·-·3f?ff+---~~,....· --1" •••~ .• -""-.~ .•
._- .------ _.-..~,.------- -- ..---
[qr7J II-~ 3(i)] 337
(A) Iron weights, parallelopiped (50 kg to 5 kg)
,(6) Cylindrical knob type weights (10 kg to 19)
(C) Iron weights, hexagonal (50 kg to 50 g)
(D) Bullion weights (10kg to 1 g) and
(E) Sheet metal weights (SOD mg to 1 mg)
A.-IRON WEIGHTS PARALLELOPIPED (50 kg to
5 kg)
1. Denominations
Parallelopiped Iron weights shall have the
following denominatlons:-
Kilogram series: 50,20,10 and S.
2. Shape
(a) The weights shall be integral and in the form
of parallelopiped rectangles with corners
rounded off and having a rigid handle for
. ease of handling.
(b) The shapesshall be as shown either In FlQure
3 or In Figure 4.
3. Material
(a) Body: The body shall be made or
manufactured from grey cast Iron.
(b) Handles: Handles shall be made or
manufactured from the following materials:
(i) Type 1 weights-Steel tube without
soldering
(ii) TYpe2 weights-Cast along with the body
(c) Method of manufacture:
The weights shall be made or manufactured by
means of any suItable foundry and moulding process.
4. Loading holes
(a) The weights shall be provided with loading
holes of either Type 1 or Type 2 indicated
below:
Type Jloading hole
(i) The loadIng hole shall be located within
the tube which forms the handle (See
Figure 3).
(ii) The loading hole shall be closed either
with a screwed brass plug or a brass
TABLE 1
disc. The screwed brass plug shall be
provided with a screw driver slot and
the brass disc shall have a central hole
to facilitate lifting.
(iii) The plug or a disc shall be sealed by
means of a lead pellet pressed firmly
Into an internal drcular slot or in the
.threaded part of the tube.
TYpe2 loading hole
(I) The loading hole shall be cast in one of
the upper surfaces of the weights and
shall open out. on the upper surface
(See Figure 4).
(II) This loading hole shall be dosed by a
plate cut from mild steel.
(III) The mild steel plate shall be closed by
a lead pellet pressed firmly into the
conical hole.
(b) In case of new weights, about two-thlrd of
the depth of the loading hole shall remain
empty after adjustment.
5. Markings
(a) The denomination of the weight and the
marker'S or manufacturer's name or trade
marX shallbe indicated Indelibly in the sunken
form or in relief, on the upper surface of the
central portion of the weight. (See Figure 3
and Figure 4.)
(b) The denomination of the weight shall be
Indicated in the International form of Indian
numerals in an indelible manner with the
symbols as illustrated below: .
.~ or fcnm 5 kg
Note: The abbreviation ~ or fcfim, may be
indicated In the regional script.
6. Dimensions
(a) The dimensions of the two types of weight
shall be as specified in Tables 1 and 2.
(b) The tolerances on dimensions shall be
±5 percent.
Parallelop/ped Weights Dimensions for
7J'pe1Weights
(In millimetres)
Denomination A A' 8 8' H C 0 E F GIG'
5kg 150 152 75 n 84 36 30 6 66 12/20
10 kg 190 193 95 97 109 46 38 8 84 12/20
20 kg 230 234 115 117 139 61 52 12 109 24{32
50 kg 310 314 155 157 19i 83 74 16 152 24/32
it 7 it C. () " -85
338 THE GAZETTE OF INDIA: EXTRAORDINARY [PARTII-SEC. 3(i)]
Denomination I ] K T L N 0 U V W p
5kg 145 5 12 M16 x 1.5 14 1 2 16.5 18 16 5
10kg 185 6 16 M16 x 1.5 14 . 1 2 16.5 18 16 5
20 kg 220 8 20 M27 x 1.5 21 2 3 27.5 30 27 8
SOkg 300 10 25 M27 x i.s 21 2 3 27.5 30 27 8
Sides A and A\ as also Band B\ may be Inversed.
TABLE 2
Para/lelopiped Weights Dimensions for TYpe2Weights.
(In millimetreSj
Denomination A A' S 8' H C D E ·F G ] K M N P
5kg 150 152 75 77 84 36 30 6 66 19 5 12 16 13 55
10kg ·190 193 95 97 109 46 38 8 84 25 6 16 35 25 70
20 kg 230 234 115 117 139 61 52 12 109 29 8 20 50 30 95
SOkg 310 314 155 157 192 83 74 16 152 40 10 25 70 40 148
Sides A and A' also Band B' may be Inversed.
STOPPU
VAIUf:TY I
UADI~
PELLI:.T
r--i -;
+-·w .... ~.... _ ••• _ ........ _ ... - .... -
ll'.......Lt1Itt •
~ANtJFACTUUIU NAM!!0.
ADEMAIUt
x-_· ...
IL.__ ..J
~Ihf '"PARALLELPIPED WEIGHT TYPE 1
Rgure3
,
339
7. Finish
t=q~-c-,.--A.' '~.~.
T'Pl , .~..
0I ;..
1 ! SOlD'"I i .oil
1 !. !
L._..I
J
1---- A. -----11 -. LRaUnded Corners
Manufacturer's Name or Trade Mark
.---1".---_..
C
vi fmkg
ParallelapipedWeight Type 2
Figure 4
B.--CVUNDRICAL KNOBTYPEWEIGHTS (10 kg to
Ig)
1.DenomInations
Cylindrical weights shall have the following
denominations:
Gramseries:500, 200, 100,50,20, 10,5,2 and 1
Kilogram series: 10, 5, 2 and 1
2. Shllpe
(a) The weights shall be integral and cylindrical
In shapeand provided with a flattened knob
for ease of handling.
(b) Theshapes shall be as shown in Figure (5).
3. Materilll
The weights shall bemadeor manufactured from
brass, gun metal or bronze; grey cast iron may also
be used for weights from 10 kg to 200 g but grey cast
iron weights shall not be used for weighment of goldt
silver, precious metals or their products.
4. Method of manufacture
The weights shall be made or manufactured by
any suitable method as may be applicable to the
selected material.
5. Loading hole
(a) Weights of denominations 10 9 to 1 9 both
tnduslve, shall be solid, integral weights
without a loading hole.
The weights shall be finished smooth and be
free from dross, pitst blow-holes and other defects.
They shall be protected against corrosion byapplying
an appropriate coating which is resistant to normal
usage and wear and tear.
8. Permissible error
The maximum permissible errors shall be as
specified below:
Denomination Permissible error
Verification Inspection
(mg) (mg)
7500 ±7S00
3000 ±3000
1500 ± 1500
750 ±750
50 kg
20 kg
10 kg
5k9
9. Stamping
The Legal Metrology Officer's seals shall be
stamped on the lead pellet within the loading hole.
(See Figure 3 & Figure 4).
--------------- ---_. --------~.------------------------
340 THE GAZETTE OF INDIA: EXTRAORDINARY [PARTn-SF.c. 3(i»)
(b) Weights of denominations'10'kgto 20 9both
inclusive, shall be provided with a loading
hole.
(c) The loading hole shaltbecylindrical and shall
pass through the axis ,of the weight open
out on the upper surface of the knob and
have wider diameter at its upper end as
shown In Figure 5.
(d) The loading .hole shall be dosed either by
. means of a'threaded brass plug or a flat
brass disc. (See 'figure 5).
Note: Thethread used shaUbe that commonly
known as 'ISO Metric'.
(I) 'The threaded plug shall have a slot
for adjusting it by means of a screw
driver.
(Ii) The nat disc. shall be provided with a
suitable hole in the centre to fadlitate
handling.
(e) The plug or the flat disc shall be closed by
means a lead pellet pressed firmly Into the
drculargroove In the wider part of the loading
hole.
(f) 'Weights without a loading hole shall be
adjusted by machining or grinding.
(9) Weights with loading hole shall be adjusted
with heavy metallic materials such as lead
shots.
(h) In the caseof new weights about two-thirds
of the depth of the loading hole shall remain
empty after adjustment.
TABLE 3
6. Marking
(a) The denomination of the weight and the,
maker'S or manufacturer's name or trade
mark shall be indicated indelibly, in the
sunken form or in relief, on the flat knob.
(See Figure 5).
(b) The denominatiOnof weights of 10kilograms
to 500 grams may also be indicated on the
cylindrical body of theweight, provided that
the numerals and letters of the symbol shall
be larger than those usedfor indicating them
on the knob.
(c) The denomination of the weight shall be
Indicated In the international form of Indian
numerals in an indelible manner with the
symbols as illustrated below :
~or~5kg
ID or ID11' 100 9
Note: The abbreviation~, mr, lIT or 'llT'I'
may be Indicated in the regional script.
7. Dimensions
(a) The dimensions of cylindrical weights shall
be as specified in Tables 3 and 4.
(b) The tolerances on dlmenslons shall be :
(I) for weights 1 kg. and below ± 10 per cent;
(II) for weights above 1 kg± 5 per cent.
Cylindrical Knob 7Jt~ Weights-Dimenslon for Weights in mm.
Denomination U V' W H Y R } K
10 kg 100 90 58 According 17 15 3 10
5 kg 80 72 46 to 13 12 2 10·
2 kg 60 54 36 . material 10 9 2 5
1 kg 48 43 27 8 7 2 5
500 9 38 '34 22 6 5.5 1.5 3.2
200 g 28 25 16 4.5 4 1.5 3.2
1009 22 20 13 4 3.5 1 '2
50 g 18 16 10 3 2.5 1 2
20 g 13 11.5 7.5 2 1.8 0.5 1.5
10 g 10 9 6 1.6 1.5 0.5 1 Without
59 8 7 4.5 1.4 1.25 0.5 1 loading
29 6 5.5 3 1 0.9 0.5 1 hole
1'9 " 6 5.5 3 1 0.9 0.5 1
.. - _ .._-- _' .. --
('I:fTIT II-~ 3(i)] qmrifiT~:~ 341
TABLE4
Cylindrical Knob Type Weights-Oimension for Loading Hole ~nety I and U Inmm.
Denominations A B C D E F G L T I M N P 5
20 9 3 18 .5.5 2.5 6.5 1.5 1 9 M4 x 0.5 5 1 5 5 1
50 g 4.5 25 7.5 3.5 9 2 1 10 M6 x 0.5 5 1.S 7 7 1.5
100 9 4.5 30 7.5 3.5 9 2 1 10 M6 x 0.5 5 1.5 7 7 1.5
200 9 7 40 10:5 4.5 12 2.5 1.5 15 M8x 1 8 2 10 10 2
500 9 7 50 10.5 4.5 12 2.5 1.5 15 M8x 1 8 2 10 10 2
1 kg 12 65 IS.5 7 20 4 2.5. 20 M14 x 1.5 13 3 18 18 3
2 kg 12 80 18.5 7 20 4 2.S 20 M14 x 1.5 13 3 18 18 3
5 kg 18 120 24.5 8 26.5 4 2.5 3S M20 x 1.5 18 4 24 24 3
10 kg 18 160 24.5 8 26.5 4 2.S 35 M20 x 1.5 18 4 24 24 3
. Lo.ADVIG HCLE ~tO.e
IlIUUETYI . ·1 'II I . _1InY2
( )_"1 n'\ III! r.",.
! ./ ~
t 'J ......
:z:~--, i;r-
WD~~. .,.
~
~
u -~...
~ I I
IIAASI'
J I.
( ~
1 :~
) T
~
~
.~ ..
k':-
i IL--..'",-,"
•
I·
CYlINDRICAL. KNOB TYPE WEIGHTS
FlGURE-S
342 ,THE 'GAzETTE OF INDIA: EXTRAORDINARY . [PARTII-SEC. 3(i))
8. Finish
The weights shall be polished smooth. They
may be protected against;corrosion by applying
an appropriate coatlng.which:is resistant to normal
usage and wear-and tear.
9. Permissible error
The maximum permissible ·errors shall be as
speclfied below :
DenominatiOn Penniss7fJleerror"
YerifiCiJtion Inspection
.(mg) (mg)
1500 ± 1500
750 ± 750
300 ± 300
150 ± 150
75 ± 75
30 ±30
15 ± 15
10 ± 10
8 ±8
6 ±6
5 ±5.
4 ±4
3 ±3
·10 kg
5 kg
2 kg
1kg
500 9
200 g
100 9
50 g
20 9
10 9
5g
2g
1 9
~o.Stamping
(a) The legal Metrology Officer's seals shall be
stamped on the load pellet within the loading
hole, where loading hole is provided.
(b) The Legal Metrology Officer's seals shall be
stamped on the bottom of weights which
have no loading hole.
C.-IRON WEIGHTS, HEXAGONAL (SO kg to 50 g)
~. Denominations
Hexagonal Iron weights shall have the following
denominations :
Gram series : 500, 200, 100 and SO.
Kilogram series: 50, 20, 10, 5, 2 and 1.
2. Shape
(a) Theweights shall be integral and hexagonal.
The shape shall be.as shown In Figures 6
and 6A~
(b) The weights of denominations of 50 kg and
down to and Indudlng 5 kg shall be provided
with cast-In handles made of mild steel.
(c) The weights of denominations 2 kg and down
to and Including 50 9 shall nest wfth each
other.
3. Material
The weights shall bemade or manufactUred from
grey cast Iron.
4. Method of manufacture
The weights shall be made or manufactured by
means of any suitable foundry and moulding process.
5. Loading hole
The weights must have a loading hole fonned at
the foundry
(a) For weights in Figure 6, this hole must be In
the shape ot a right circular cone located
,axially and opening into the bottom face of
the weight with its smaller diameter.
(b) For weights in Figure 6A, this hole must be
In the shape of a frustum of a pyramid with
rectangular base and opening into the bottom
face of the weight with its smaller end.
(c) In the case of new weights about two-thirds
of the depth of the loading hole shall remain
empty after adjustment.
6. Marking
(a) The denomination of the weights and the·
maker's or manufacturer's name or trade
mark shall be indicated Indelibly in the sunken
fort" or in relief, on the upper surface of the
central portion of the weight (See
Figure 6).
(b) The denomination of the weight shall be
. Indicated In the international form of Indian
numerals in indelible manner with the
symbols as illustrated below (See Figure 6).
~orM2k9
l%T or mq 200 g
Note: The abbreviation ~,A;m, l%T or W1
may be Indicated in the regional script.
7. Dimensions
(a) The dimensions shall be as specified In
Tables 5 and SA.
(b) The tolerances on dimensions shall be:
(I) for weights 1 kg and below ±10 per cent
(iI) For y.'eights above 1 kg ± 5 per cent.
----- --------------,-----
['IT'f Il-~ 3(i)] ~CfiT~:~ 343
TABLES
Dimensions for cast Iron or Forged
Mild SteelS Weights
(All dimensions Inmlllimetres)
Denomination A 8 C D H P Q R S T
2kg_ 94 101 78 41 10 34 30 9 18 4
lkg 73 79 62 34 8 32 28 8 16 4
500g 57 62 47 27 6 23 20 6 13 3
200g 42 48 38 21 6 22 20 -4 9 3
1009 33 38 31 17 5 18 16 ·3 7 2.5
50g 27 31 24 U' 3 16 14 3 5 2
TABL£5A
Dimensions of CastIron Weights with Cast-in Handles
(Dimensions in mm)
Denomination A 8 C D E G P Q R S T
50 kg 236 253 134 170 100 27 58 48 24 102 32
20 kg 188 200 112 113 90 21 44 38 19 66 22
10 kg 152 161 92 88 74 18 36 30 15 54 19
5kg 125 132 7S 65 62 15 29 25 12 40 16
8. Finish
The weight shall be finished smooth and be free
from pits, blow-holes and other defects. They shall
be protected against corrosion by applying an
appropriate coating which is resistant to normal usage
of wear and tear.
9. Permissible elTC)r
The maximum permissible errors shall be as
specified below:
Denomination Pennlsslble en-or
Verification Inspection
(mg) (mg)
7500 ±7500
3000 ±3000
1500 ±1500
750 ±750
300 ±300
150 ±150
75 ±7S
30 ±30
15 ±15
10 ±10
so kg
20 kg
10 kg
5 kg
2 kg
1kg
500g
200g
~OOg
50g
10. Stamping
The Legal Metrology Offlcer's seals shall be
_stamped on the lead pellet within the loading hole
- (See Figure 6).
CASTIRot! Ql ~<l"'OEOWILDSTf.EL
. WII.IW-c •• "' .... FIG·6
D.-8UWON WEIGHTS(10 kg to 1g)
1. Denominations
Bullion weights shall have the following
. denominations:
Gram series: 500,200, 100, 50, 20, 10, 5,
2 and 1.
Kilogram series: 10, 5, 2 and 1.
- -I. ~_ ~ » __
344 ':THE· GAlBToTE OF 'INDIA: EXTRAORDINARY - [PARTII-SEC. 3(i)]
2. Shape
Bullion w~jghts shall be.ofthe followil"!g ·.two
types :
(i) CyIlndrical:knobtypes-<yli ndricaIknob type .
weights.of denomination 10 kg to 1 g,'both
inclusive, shall beotthe shapeesspecified
in pa~graph:B=2_of.this·Part(Seealso Rgure
5) but.shall bear .indications, spedfied in
parag~ph 6 to Indicate·thaHhey are bullfon
weights.
(ii) Flat ~lindrlcal type--;F1at CYlindrical type
weights of,denominations 1 kg to 1 9 both
Induslv~,:shall.be ·f1at cylindrical In shape,
without a:knob·and·shaUnest with eachother
(See F.lgure·,7).
3. Material
Weights shell be rnade or manufactured from
brass, gun meta!,'bronze or the like.
4. Method ofmanufacture
Weights shall 'be either cast, pressed or turned
from rods, or :made or manufactured by any other
suitable method.as may beapplicable to the selected
material.
5. Loading holes
(a) Weightsof denominations 10kg to 20 g, both
inclusive, made or manufactured according
to requirements specified in paragraph 11
of thIs Part, shall have loading holes of the
type specified for them.
(b) Weights of denominations 10 g to 1g, both
inclusive of either type shall be solid Integral
weights without a loading hole.
(c) Flat cylindrIcal weights from 1 kg to 20 g
both Inclusive, shall have loading holes, in
the shape of a right circular frustum of a
cone located axially and opening Into the
TABLE6
bottom face of the weight with its smaller
diameter (See Figure 7).
(d) In the case of new weights about two-thirds
of the depth of the loading hole shall remaIn
empty after adjustment.
6. Markings
(a) The denominations and other marking on
cylindrical knob type weights shall be as
specified in paragraph 15 of this Part.
(b) Cylindrical knob type weights of
denomination 100g to 19, both inclusive,
shall be marked on the bodywith a 'diamond'
and those of denominations 10 kg to 200g,
both inclusive, shall be marked on the knob
with the words 'Bullion' and (~) within
a 'diamond'.
(c) The denominations of flat cylindrical weights
and the maker's or manufacturer's name or
trade mark shall be Indicated indelibly, in
the sunken form or In relief, on the upper
surface of the central portion of the weights
(See Figure 7). .
(d) Flat cylindrical weights of denominations 10
g to 1 g, both indusive, shall be marked with
only a 'diamond' and those of denominations
1 kg to 20 g, both inclusive, shall be marked
with the words 'Bullion' and (~) within
a 'diamond'. .
(e) The denomination of the weight shall be
Indicated in the international form of Indian
numerals in an indelible manner with the
symbols as illustrated below (See
Agure 7):
~or~2kg
m or '!fI11 10 g
DIMENSIONS FOR FLATCYllNDRICAL BULLlON WEIGHTS
(All dimensions in millimetres)
Denomination A 8 C D E F G
1 kg 80 61.5 20 23 4,0 12 26.6
500g 61 48.5 16 19 2.5 10 22.5
200g 48 37.5 14 16 2.0 7 14.8
100g 37 28.5 12 14 2.0 6 12.7
50g 28 21.5 10 11 1.5 3 11.0
209 21 16.5 9 10. 1.5 3 8.4
109 16 12.5 ** ** 1.5 ** 6.9
5g 12 9.5 ** ** 1.0 ** 5.9
2g 9 7.0 ** ** 1.0 ** 4.4
19 6.5 ** ** ** ** ** 3.6
-r .. ·,..1'!"f·",......'~MMf;'''['It·..···__.,~. ,
, I___ -L _
, ,.. ,- •.~__..__..__ .n' ~ ~ ....---flt...,T">,....t- .,.·-t .,..,
- _" -----------
'. ,to, ,0 •
qffiJ CfiT ~ : amT'iRUT _ 345
(1) (2) (3)
200g 10 ±10
100g 5 ±5
50g 3 ±3
20g 2.5 ±2.5
109 2.0 ±2.0
59 1.5 ± 1.5
29 1.2 ±1.2
19 1.0 ± 1.0
[q-py II-~ 3(i)]
r----__A " -.
r----- B " _
Flat Cylindrical Bullion Weights
Figure - 7 .
Note: The abbr~viation ~, fifi!n, lIT or mll'
may be indicated In the regional script.
7. Dimensions
(a) The dimensions of cylindrical knob type
weights shall be as specified InThbles3 and
4.
(b) The dimensionsc:J flat cylindricalweight shall
be as specified in Table 6.
(c) The tolerances on dimensions for bOth types
of weights shall be-
(i) for weights 1 kg and below ± 10 per
cent.
(ii) for weights above 1kg± 5 per cent.
8. Finish
The surface of the weights shall be polished,
smooth and shall not show any porosity to the naked
eye.
9. Permissible error
The maximum permissible errors shall be as
specified below:
Oenomination Permissibleerror
Verification Inspection
(mg) (mg)
(1) (2) (3)
10 kg
Skg
2kg
1kg
500g
500
250
100
50
25
±500
±250
±100
±50
±25
, 10. stamping
(a) The Legal Metrology Officer's sealsshall be
stamped on the lead pellet within the loading
hole, where loading hole is provided.
(b) The Legal Metrology Officer's seals shall be
stamped on the bottom of weights which
have no loading hole.
E.-5HEET METAL WEIGHTS
1. Denominations
Sheet metal weights shall have the following
denomlnatlons:-
Milligram series: 500, 200, 100, 50, 20, 10, 5, 2
and 1.
z, Shape
(a) Bullionweights shall be drcular in shapeand
shall haveoneedge bent for ease of handIing
(See Figure 8).
(b) Non-bullion weights shall have the following
shapes and shall have one edge bent for
ease of handling (See Figure 9).
Denomination(mg) Shapeafter bendingalong
one of the sides
5,50,500
2,20,200
Equilateral triangle
Square
Regular hexagonI, 10, 100
3. Material
Sheet metal weights shall be made or
manufactured from brass, stainless steel, aluminium
nickel-silver or cupro-nickel sheets.
4. Method of manufacture
Sheet metal weights shall be made or
manufacture by pressing or by any other suitable
process.
5. Markings
(a) Sheet metal weights shall bear only the
denomination and symbol for 'milligram' as
346 .THE GAZETTE OF INDIA: EXTRAORDINARY [PARTII-SEC. 3(i)]
TABlE 7
DIMENSlONs FOR SHEET METALWEIGHTS
(NON-BULUON)(Rgure 9) (All dimensIonsInmill/metres)
Denomination Al A2 A3 B H
(mg)
50 14.0 2.0 3.0
200 12.0 2.0 3.0
100 12.0 2.0 2.5
50 8.0 1.5 2.5
'20 7.0 1.5 2.5
10 7.0 1.5 2.5
5 4.5 1.0 .2.0
4.0 ... 1.0 2.0
4.0 1.0 ·2.0
indicated below (See also Figure 8 and
Figure 9). .
(fi:!m) 500 mg
Note :The abbreviation 1lmT may be Indicated
In the regional script.
(b) Themaker's or manufacture's name or trade
mark shall be indicated indelibly on the box
containing the sheet metal weights.
. (c) The box shall also bear a serial number to
identify it.
6. Dimensions
(a) The dimensions of sheet metal weights shall
be as specified in Tables 7 and 8.
(b) .The tolerances on dimensions shall be
± 10 per cent.
TABLES
DIMENSIONS FOR SHEET METALWEIGHTS
(BULUON) (FIgureS)
(All dimensions in millimetres)
Denomination , D C H
2.0
2.0
2.0
1.5
1.5
1.5
1.0
1.0
1.0
15
13
11
9
8
7
6
5
.4
3.0
3.0
2.5
2.5
2.5
2.5
2.0
2.0
2.0
500 mg
200 mg
100 mg
SO mg
20 mg
·10 mg
5 mg
2 mg
1mg
7. Finish
The sheet metal weights-shall be clearly sheared
and free from burrs. The stamped markings on sheet
metal weights shall be legible and deep enough to
ensure Indelibility but not so deep as to crack the sheet
metal weights.
8. Permissible error
The maximum permissible errors shall be as
specified below:
Denomination (mg) Maximumpennissible error
Verification lnsDecfiOn
Bullion(mg) Non-bullion(mg)Bullion(mg) Non-bullion(mg)
500 0.8 2.5 ±O.8 ± 2.5
200 0.6 2.0 . ± 0.6 ±2.0
100 0.5 1.5 ±O.S ± 1.5
SO 0.4 1.2 ±OA ± 1.2
20 0.3 1.0 ±0.3 ± 1.0
10 0.25 0.8 ±O.2S ±O.8
5 0.20 0.6 ±O.20 ±0.6
2 0.20 0.6 ± 0.20 ±O.6
1 0.20 0.6 + 0.20 + 0.6
-_- ---------------~---'
['1J1T II-~ 3(i)] 347
9. Stamping
(a) 'legal Metrology Officer's seals shall not be
affixed on weights of 10 mg, 5 mg, 2 mg
and 1 mg. These weights shall be
authenticated by the Issueof a certfficate of
verlfiCiltionwhich shall also mentlon the serial
number on the box containing the weights.
(b) Legal Metrology Officer's seal for year alone
shall be stamped on sheet metal weights of
20 mg.
Figure 8
Sheet Metal Bullion Weights
H-1500
,,
I
I
I
•• 200
......Ho-+· -500 "'.I
I
•I,
J........_-_,.j..-
f1:mT mg
_.
, ftmr mg
Figure 9
Sheet Metal Weights
-~~.---
348 THE GAZETIE OF INDIA: EXTRAORDINARY fPARTII-SEC.3(i)]
(c) The legal Metrology·0fficer~s,seals.(namely,
year, Quarter and identification) shall be
stamped on sheet metal weights of
denominations' 500 mg to '50 mg, both.
indus[ve.
3. Knob weights
(a) Materials
(l) The weights shall be made from
rolled, drawn or extruded material
and shall not be cast.
(ii) The weights shall be made from
brass, bronze, gun·metal, ntckel
chromium alloy or non-mecnenc
stainless steel.
(b) Shape and dimensions
The shape and dimensions of the weights
shall be as shown In Figure 10 and Table 9.
(e) Permissible error
The maximum permissible errors shall be
as specified below:
PART II
CARAT WEIGHTS
1.General
This Part deals with the requirements for carat
weights intended for use in weighing pearls, diamonds
and other preciOusstones.'
2. Denomination.
The denominations·of carat weights shall be as
given below (the gram 'and .milligram equivalents are
shownagainsteachfor 'ready reference) :
(a) KNOB WEIGHTS (b) SHEET METAL WEIGHTS
Denomination Equivalent
carat 9
Denomination Equivalent Denomination Verification InspectIoncarat mg
2 400 C3rat mg mg
1 200 500 5.0 ±5.0
0.5 100 200 3.0 ±3.00.2 40 100 2.5 ±2.S0.1 20
0.05 10 SO 2.0 ±2.0
0.02 4 20 1.5 ± 1.5
0.01 2 10 1.2 ±1.2
0.005 1
5 1.0 ±1.0
TABLE9
NOMINAL DIMENSIONS OF KNOB CARAT WEIGKTS
[Clause 3(b}]
(All dimensions in millimetres)
A* C** D E F G H
12.0 0.4 4.0 10.0 6.0 32.0 14.2
10.0 0.4 3.0 8.5 5.0 23.0 10.8
8.0 0.4 2.5 7.0 4.0 19.0 7.9
6.0 0.3 2.0 5.5 3.0 15.0 6.4
5.0 0.3 2.0 4.0 2.0 11.0 4.6
4.0 0.3 1.5 3.0 1.5· 9.0 3.5
3.0 0.2 1.5 2.5 1.5 7.0 2.9
500 100
100 '10
100 20
50 10
20 'I
10 2
5 . 1
Denominations carat
500
200
100
SO
20
10
5
* The cross-section of the top of theknob is elliptical for a/l weights major axis beIng twice the minor sas
(therefore for a/l weights B::;:;A/4)
* * This Is8 recommended dimension .
. , ,- .." --....
--_..l L
---' ...------- .-._-
['WI I1-~ 3(i)]
Note: With a material of density 8400 kg/m3
(exactly) the above dimensionswill give weights which
possessmassesto within the required tolerance limits
on the plus side (this ensures a longer life for the
weights). However,as the density of the material may
vary considerably as also the manufacturing
techniques, a tolerance of ±10 per cent Is allowed on
all obligatory dimensions (that is those other than C).
Final values of massescan be adjusted by controlling
the dimension H.
4. Sheet metal weights
(a) Materials-Weights of denominations 0.2
carat and below shalfbe made of aluminium
sheet. Weights of higher' denomInations
shalfbemade of sheets of brass, aluminium/
nickel-silver, nickel chromium alloy, bronze
or cupro-nlckel.
(b) Shape and dlmensions-5heet metal weights
shall be square with one edge bent for ease
of handling (See Figure 11)•. They shall
have dimensions given in Table 10.
(c) Permissibleerror
The- maximum permissible errors shall be as
spedfied below:-
Denomination
Carat
349
Verifialtlon Inspection
mg- mg
2 3
O.S ±O.8
0.6 ±O.6
0.5 ±0.5
'0.4 ±0.4
0.3 ±O.3
0.25 ±0.2S
0.20 ±0.20
0.20 ±0.20
0.20 +0.20
1
2
1
0.5
0.2
0.1-
0.05
0.02
0.01
0.005
TABLE 10
Nominal dimension forsheet metal carat
weights
Denomlfl8t1on Size
Carat mm
2 12
1 10
O.S 9
0.2 8
0.1 7
0.05 6
0.02 5
0.01 4
0.005 3
Tolerance± 10 percent
Manufacturers Name or
TradeName
Figure 10
Knob Carat Weight
H
Figure 11
Sheet Metal Carat Weight
350 -tFHE<G;'&;zEITE ;OF INDIA: EXTRAORDINARY [pAItt n-sEC, 3(i)]
5. Manufacture an'd1Inlth
. .
(a) The surface of 1.the 'weights shall be
reasonabJy smooth. Sheet :metal weights
shall be smooth!v:sheared and shall be free
from burrs. .
(b) For better stablliw,and flnish, the weights
. may be:nlcke!,:..Or,t:hodium:plated.
6. Marking
(a) Every welgt\t,e.xcept weights of SOcarat and
lower .denommettcns, shall have the
nianufacturer's name or trade marl<and the
denomination Indelibly marked on It.
(b) The denomlnatlon shall consist of the
International form of Indian numeral prefixed
and sL:ifflxed by the letter '~' and 'c'
respectively except that In the case of
weights below 50 carat, only the numerals
shall bemarked. The size of numerals and
letters Indicating the denomination of
weights shall be at least twice the size of
letters Indicating the manufacturer's name
or trademark. '
Note :The abbreviation '<t' may be indicated
in the regional script.
(c) The marking shall be legible and deep
enough to ensure indelibility over a long
. period of use, but not so deep as to crack
the weight itself.
7. Packing
(a) Each set of carat weights shall, In addition
to the seriesof denomination speclf1eclunder
2, consist of an additional piece of weight of
2 carat and the relevant decimal multiple of
two.
(b) The weIghts shall be supplied In a suitable
velvet-lined box. The. small sheet metal
weights shall be so housed and provided with
a cover of glass or any other transparent
material that they will not get dislodged from
their proper places. The box shall also
contain a pair of forceps for lifting the
weights.
PART III
STANDARD WEIGKTS FOR TESTING OF HIGH
CAPAcnY WEIGHINGMACHINES
1. Scope
These specifications shall apply to standard
weights having a nominal value equal to or greater
than 50 kg, used for testing (and adjusting, where
appropriate) of high capacity weighing machines In
accuracy class III(medium) and class IV (ordinary),
defined In the Metrological regulations for non
automatIc weIghing machines.
(a) It sets forth the technical and metrologIcal
requirements to which these standard weights must
conform. In particular it establishes the values of the
maxImum permissible errors for standard weights and
minimum densIties as functions of the maximum
number of scale divisions on the machines to be
verified using these weights.
2. Nominal values •
The nominal value of the standard weight Is 50
kg, or of the form k x 10n kg, where k is generally
.equal to 1, 2 or 5, and n is whole number equal to or
greater than 2.
3. Shape
I
The standard weights must have a relatively
simple shape, with no sharp edges or comers. They
shall not have any cavities liable to cause a rapid
accumulation of dirt. If they are Intended to run on a
flat surface (or on rails), they must be equipped wIth
roller tracks (or grooves) of limited area.
4. Basisof adjustment
The standard weights must be adjusted taking
the reference conditions applicable to the adjustment
of standard weights as follows:
(a) standard reference density: 8000 kg/ml,
(b) ambIent air density: 1.2 kg/m3, and
(c) equilibrium in air at 200c, without correction
for aIr buoyancy.
-.-------.- ...--'~--;---. ------ ---
[IWT1I-~ 3(i)] 351
S. Adjusting cavity
The standard weights must indude one or more
adjusting cavities. It must be possible to seal the
closure of these cavities; the dosures must bewater·
tight and airtight (e.g., bymeans of a joint). The volume
of adjusting cavities must be at least equal to 5/100
of the volume of the standard weight. Furthermore, it
is desirable that, after the initial adjustment, a volume
of at least 1/100 of the volume of the standard weight
remains empty.
6. Material
Standard weights are in general made of grey
cast Iron. They may be made of one or more other
materials, provided the provisions of paragraph 8 are
observed. The material used must be of such hardness
and strength that they withstand the loadsand shocks
liable to occur under normal conditions of use.
7. Surface condition
The standard weights may be coated with
materials suitable for providing protectIon agaInst
corrosion by rendering their surface impermeable. This
coating must wIthstand shocks and atmospheric
conditions. Zinc-plating Is an example of a coating
which meets with these specifications.
8. Metrological characteristics
The maximum permissible error for the standard
weights must not exceed 1/3 'of the maximum
permissible error for the corresponding load
considered, on the weighing machIne under
verification. The absolute error for various
denominations of standard weights shall be as given
InAnnexure 1.These maximum permissIble errors for
the standard weights must therefore be compatible
with the number of scale divisions on the machines
which they are Intend toverify. Furthermore, the density
of standard weights must besuch that a Variation of ±
10 per cent ambient air denSity, with respect to its
reference value, does not produce a variation, In the
result of weighing the standard weight In air,exceeding
1/4 of its maxImum permlsslble error. By way of
application of these requirements, the following table
gives examples of the relation amongst :-
(a) the maximum number of scale divisions "n"
on weighing machines under verification
(assumed to be in accuracy dass III);
(b) the maximum permissible positIve or
negative relative error on standard weIghts
. usedfor initial verification of these machines;
and
(c) the corresponding lower limit for the density
of the standard weights.
TABLE
Maximum number MaximumPermissible Minimum
of scale divisions positive or negative density
~n" on weighing relative error on the kg/mJ
machines standard weights
(accuracydass
Ill), capableof
verification with
the standard
weights during
verification
(1) (2) (3)
1000 3.3/10000 1231
3000 1.7/10000 2087
5000 1.0/10000 3000
10000 0.5/10000 4364
Note : Independent of the requirements
concerning the density of the weights, it is desirable
to obtaln-particularly for reference standards or those
-of a high nominal value-a density of about 8000 kg/
ml. For example, a cast iron body may beused, which
incorporates a special cavity In which a lead core may
be cast, with a mass of approximately 30 per cent of
the total nomInal mass of the standard.
9. Inscriptions and markings
Standard weights must carry their nominal value
in numerals, followed by the symbol for the unit used
and a verification mark.
10. Adjustment and verification
Adjustment of the standard weights must be such
as to comply with the maximum permissible errors
given In this specification. In particular this may be
achieved In the case of adjustment by the double
substItUtion weighing technique (Gauss transposition
method, or Borda substitution method), using as
. reference standards, weights haVing an error of less
than 1/3 of the maximum pe