LawGrids logoLAWGRIDS.ORG

The Petroleum Act (1886) Amendment Act, 1890, 14 of 1890

Central Repealed act - Repealed

Repealed

This Act is repealed. Note: (Rep., Act 8 of 1899)

This text is shown as one document.

Full text

Ameridment of schedule to Act XIT of 1886, 166 ‘Petroleum: < ss [aor xiv ACT No: XIV or 1890. Passep BY THE Governor. GenERAL OF Inpia In Councit. (Heseived the assent of the Governor General on the 31st July, 1890.) ‘An Act: to amend the Schedule to the Petro-leum Act, 1886. HEREAS it is expedient to amond parts of the fourth paragraph (Application of the test) of Part III of the schedule to the Petroleum Act, 1886; It is hereby enacted as follows :— 4, For the third and fourth clauses of the said paragraph commencing respectively with the words “Tf the flash takes place at any temperature below 77° Fahrenheit” and “No flask which takes place within eight degrees of the temperature at which the testing is commenced,” the following shall be substi-tuted, namely :— “Tf the flash takes place at any temperature below 77° Fahrenheit, the temperature at which it occurs is to be recorded. ‘Two fresh portions of the sample are then to be successively tested in a similar manner and the results recorded. If no greater difference than 2° Fahrenheit exists between any two of the three re-corded results, and if in no instance the flash has taken place within eight degrees of the temperature at which the testing is commenced, each result is to be corrected for atmospheric pressure as hereafter described, and the average of the three corrected results is the flashing point of the sample. In the event of there being a greater difference than 2° Fahrenheit between any two of the results, while in no instance ‘has the flash taken place within eight degrees of the temperature at which the testing was commenced, the series of tests is to be rejected, and a fresh series of three similarly obtained, and so on, until a sufficiently concordant XII of : 1890.] Petroleum, = sMGT concordant series is furnished, when the results are to be corrected and the average taken in the manner already described.. “Tf, however, a flash has occurred at of below 64° when the test is applied in the manner above de-scribed, the next testing shall be commenced ten degrees lower than the temperature at which the flash had been previously obtained (that is to say, at. 54° or thereunder), and this procedure shall be continued until. the results of three consecutive tests do not show a greater difference-than 2°, and until a flash has not occurred in any. of the three tests within eight degrees of the temperature at which the testing is commenced: Provided always that if at the com-mencement. of the series of tests.a flash has oceurred. on the first application of ‘the test-flame at 56°, and if a flash has also occurred on the first application of the flame in each of three’ successive tests in which, thereupon, the test-flame: is first applied at 46° as above’ directed, the testing officer shall certify that the petroleum has a flashing point. below 47° aud the sample shall be reported dangerous.”